Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung Adaptec, modell ICP5805BL

Hersteller: Adaptec
Dateigröße: 30.84 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:
Andere - ICP5805BL (31.05 kb)
Andere - ICP5805BL (213.11 kb)en
Andere - ICP5805BL (196.21 kb)en
Andere - ICP5805BL (2.93 mb)

Anleitung Zusammenfassung


4.4 Windows for EM-64T and AMD-64 - RAID adapters do not produce an audible alarm on 64-bit Windows operating systems, including: o Windows XP Professional x64 Edition o Windows Server 2003 x64 Edition (all versions) 4.5 Linux - When you delete an array, the operating system can no longer see the last array. WORKAROUND: To allow Linux to see the last array, restart your system. - The controller does not support attached CD drives during OS installation. - To remotely manage a Linux system from a Windows system, you must use the standalone GUI. - If you cannot connect to a local or remote ICP Storage Manager installed on a Linux system, verify that the TCP/IP hosts file is configured properly. 1. Open the /etc/hosts file. NOTE: The following is an example: 127.0.0.1 localhost.localdomain localhost matrix 2. If the hostname of the system is identified on the line with 127.0.0.1, you must create a new host line. 3. Remove the hostname from the 127.0.0.1 line. NOTE: The following is an example: 127.0.0.1 localhost.localdomain localhost 4. On a new line, type the IP address of the system. 5. Using the Tab key, tab to the second column and enter the fully qualified hostname. 6. Using the Tab key, tab to the third column and enter the nickname for the system. NOTE: The following is an example of a completed line: 1.1.1.1 matrix.localdomain matrix where 1.1.1.1 is the IP address of the server and matrix is the hostname of the server. 7. Restart the server for changes to take effect. - With Linux kernel versions 2.4 and 2.6, the ARCCONF DELETE command may fail with a Kernel Oops error message. Even though the drives are removed from the ICP Storage Manager console, they may not really be deleted. Reboot the controller; then, issue the ARCCONF DELETE command again. - On certain versions of Linux, you may see messages concerning font conversion errors. Font configuration under X-Windows is a known JVM problem. It does not affect the proper operation of the ICP Storage Manager software. To suppress these messages, add the following line to your .Xdefaults file: stringConversionWarnings: False - Some pop-up identification boxes include complete window frames when running the ICP Storage Manager in bootable-CD mode. These pop-ups may run off the side of the screen due to the extra width of the window frame. This is a known problem of the fvwm window manager on the CD. - On rare occasions, the online help system may generate a Java exception. This is due to a known problem in the HTML rendering section of JFC/Swing. -------------------------------------------------------------------- 5. RAID Level-Specific Notes 5.1 RAID 1 and RAID 5 Notes - During array migration from a RAID 1 or RAID 5 to a RAID 0, if the original array had a spare drive attached, the resulting RAID 0 retains the spare driv...

Dieses Handbuch ist für folgende Modelle:
Andere - ICP5125BR (30.84 kb)
Andere - ICP5085BL (30.84 kb)
Andere - ICP5045BL (30.84 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien