Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Chamberlain, modell DC2000

Hersteller: Chamberlain
Dateigröße: 5.87 mb
Dateiname: 0151128.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


N.O. N.O. USE ONLY 12 VDC FAILSAFE PHOTOCELL SENSORS FOR THIS SAFETY OPTION Failsafe Photocell: If a photocell is not working or loses power or photo beam is blocked, then the photocell will stop all gate operation. “Optional Photocell Sensor” 12 VDC Interlock Assembly 5 4 1 2 3 4 Com Com Com 4 5 SAFETY OPTIONS DC2000 Back-Up Wiring for the OmniControl™ Board with Optional Equipment Power +12 VDC Power Ground Part # AEXITP Part # A1KX Part # 312HM Part # 373LM Part # AOMRON12V 4 4 4 4 If the DC2000 is automatically opening the gate due to a power failure, any manual command such as “Manual One-Button”, “Three Push Button”, “Key Switch”, “Photocell” or “Edge Sensor” will cancel the automatic mode of the DC2000. After such cancellation, the DC2000 will continue to operate in manual mode until 115 Vac power is restored. If 115 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with ANY of these devices shown. EMERGENCY OVERRIDE J5 POWER OVERLOAD DC-BACKUP ALARM SENSOR BACKCK -B DC2000 Harness Red Wire J5 White Wire Green and Purple wires wrap behind board to the limit switches Audio Alarm Wires DO NOT remove existing wires from the audio alarm or secondary protection sensor. “Manual” setting: The DC2000 will respond to the input devices wired to the J 20 socket. This mode can also be used as an emergency override. If 115 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with input devices wired to J 20 socket. “Auto” setting: The DC2000 opens the gate automatically upon 115 Vac power failure and stays open. When 115 Vac power is restored, the gate operator will return to normal operation. (The gate can be closed by manual command) System Setup Manual Mode Auto Mode Push and Hold to operate gate 115 Vac Power Failure 115 Vac Power On, OmniControl Board™ Malfunction 115 Vac Power On, Emergency Override Gate automatically opens Turn the 115 Vac power off then push and Hold to operate gate Push and Hold to override the OmniControl™ Board Push and Hold to override the OmniControl™ Board Turn the 115 Vac power off then gate opens automatically For Technical Support and Ordering Parts: 1-800-528-2806 OPEN CLOSE DO NOT wire 115 Vac power to the DC2000 DC2000 Harness Jumper P3: to 12 Volt Jumper P2: to Constant (C) ® Button One: Normal Gate Operation (OmniControl™ Board) Button Two: Back-Up Operation (DC2000) Button Three: Optional Accessories Push and “Hold” DC2000 Remote Button to Open Push again and “Hold” DC2000 Remote Button to Close 6 3 4 Refer to Receiver Manual for Further Details about settings. Button One: Normal Gate Operation Only (OmniControl™ Board) Separate 12 VDC DC2000 Radio Receiver Interlock Assembly Wire 4 3 Factory installed Interlock Assembly Wires to J20 Socket Cut and Discard Plug To Limit Switches Radio Receiver + Radio Receiver - 13 11 11 12 24 VDC Factory Installed Radio Receiver 1 2 3 11 11 13 12 4 J 20 STEP 7 STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 8 SL3000UL™ & SL3000ULDM™ with Interlock Assembly Step-by-Step DC2000 Installation Bolt the DC2000 plate and guard to the operator chassis. Do not tighten the bolts. Adjustment is required in Step 3. Bolts Plate Bolt the DC2000 control unit to the plate. Bolt the DC motor to the plate. Connect the DC motor wires to the DC2000 control unit wires. Red to Red and Black to Black. DC Motor Remove interlock assembly from motor with 3 screws. Replace the existing belt with the new belt provided. Make sure that the pulleys are aligned. Pull down the DC2000 Plate to tighten the belt tension. Tighten the plate bolts to secure the plate. Reattach interlock assembly. SL3000UL™ Use 4L 370 Belt SL3000ULDM™ Use 4L 400 Belt Do not over tighten belt W4 OFF ON J5 POWER OVERLOAD DC-BACKUP ALARM SENSOR BACK-BACK Connect the purple and green wires to the limit switches. Make sure brown wire is in the “Common” connector on the limit switch. Remove the OmniControl™ board from the electrical box. Plug in the DC2000 harness into the DC2000 control unit. Feed the DC2000 harness through the bottom of the electrical box. Feed the green and purple wires to the limit box. OFF ON W4 Unplug interlock wire from OmniControl board, cut the plug off and strip wires. Insert Red wire in J-20 socket 3 and Black wire into socket 4 of the DC2000. 1 NC 2 3 NO COM Brown Red Yellow Orange Purple Green NC 1 2 3 NO COM Top View of Limit Switch Box DC2000 Control Unit Existing Belt Reinstall the OmniControl™ board and make sure that the green and purple wires do not get pinched by the board. Plug in the DC2000 harness in the DC-BackUp J5 slot on the OmniControl™ board. Connect the red wire from the DC2000 harness into the top slot of the audio alarm plug. (DO NOT remove audio alarm wires) Connect the white wire from the DC2000 harness into the bottom slot of the sensor plug. Set switch for the gate direction. (Open left or Open right) Select your mode of operation ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien