|
Anleitung Zusammenfassung
Make sure a label is under the sensing area. 2. Depress the push-button until the green LED begins flashing at a slow rate (5 sec.), then release. If the green LED flashes at a fast rate it indicates that the label was not positioned correctly and you need to start over. 3. Jog 1 label. Missing Label Compensation is now enabled and should function correctly. Disabling Missing Label Compensation: 1. Depress the push-button until the green LED begins flashing (5 sec.), then release. . 2. Depress the push-button once again to disable. *You can also disable Missing Label Compensation by selecting Level Shift Output. Refer to Program Mode (page 12) for more information. - 11 Program Mode Program Mode Entering Program Mode: Program Mode is used to change any or all of the Operation Features. To enter Program Mode depress the push-button until the yellow and green LED's begin toggling (30 sec.), then release. The LED's will then output the current set-up configuration (and every 3 sec. thereafter). For example: an output of yellow, yellow, yellow tells you that the current configuration is Level Shift, Light Operate, and Normal Contrast Setting. Table of Features: 1 OUTPUT MODE *A. Level Shift - (default factory setting) Yellow LED B Pulse Green LED LIGHT/DARK OPERATION *A. Output on Web - Light - (default factory setting) Yellow LED 2 Level Shift Output WEB LABEL ON OFF Pulse Output WEBLABEL LABEL ON 2 m.s. OFF OFF B. Output on Label - Dark Green LED Level Shift Output WEB LABEL ON OFF Pulse Output WEBLABEL LABEL ON ON2 m.s. OFF 3 CONTRAST SETTING *A. Normal Contrast Setting - (default factory setting) Yellow LED B. Low Contrast Setting Green LED Changing a Feature: To change a feature, depress the push-button the corresponding number of times. This will change the current feature from A to B, or from B to A. For example: If you wanted to change the output from Level Shift to Pulse, you would depress the push-button 1 time - the LED's would then output green, yellow, yellow. Repeat this step if you want to change more than one feature. Exiting Program Mode: To exit Program Mode depress the push-button until the yellow and green LED's begin toggling (2 sec.), then release. This puts you back in the standard operating mode. - 12 Specifications Specifications General: Power Supply..................................................... 10-30 VDC, reverse polarity protected Power Consumption............................................ 50mA max. Output.............................................................. NPN / PNP open collector Output Current................................................... 100mA max., reverse polarity & short circuit protected Response Time.................................................. 10 microseconds Output Voltage Drop........................................... 0.5V max. (NPN) @ 10mA . 1.5V max. (NPN) @ 100mA . 0.5V max. (PNP) @ 10mA . 1.5V max. (PNP) @ 100mA Emission........................................................... IR LED (880 nm) Indicators.......................................................... Yellow LED -Indicates label backing only . Red LED - Indicates output state and errors . Green LED - Indicates label + label backing CS2000 Connections.......................................... 8' cable - 4 conductors CS2000-QD Connections..................................... 6" Quick Disconnect M12 4 Pin Male Cable/Connector (Turck P/N RS4.4T-2) Slot Width......................................................... 0.093" (2.4mm) Slot Depth......................................................... 3.00" (76.2mm) Min. Label Gap (matrix) Detection......................... 0.03" (.76mm) Housing Material................................................ Double Hard Anodized Aluminum - 13 Specifications Specifications Dimensions: CS2000 0.44 11.2 0.625 1.00 25.4 0.625 15.9 79.4 3.125 50.8 15 0.59 2.00 0.22 5.6 0.75 19.1 0.50 12.7 15.9 0.09 SensingArea 15.9 0.625 76.2 3.00 EASY SETUP WEB OUT LABEL 13.5 0.53 1.00 88.9 3.50 25.4 9.5 0.38 2.4 1. 2. 3. 4. Position web under sensing area and hold button down until yellow LED comes on. Release button and yellow LED will flash. Move label under sensing area and green LED will come on. Setup complete. - 14 Cleaning Instructions Cleaning Instructions Cleaning Instructions: 1. Begin by removing the sensor lid's 4 screws with a 1/16" L wrench. 2. Gently lift the sensor's circuit board out by grasping the switch and pulling upward. Do not remove the insulation tape. 3. Clean the lens of the sensor's photo eye with a clean soft cloth moistened with 99% isopropyl alcohol (available from most electronics supply & tool distributors - e.g. Techni Tool, Contact East, Jensen Tools, Future Active, etc.) 4. Lightly scrape off sticky label residue using an Xacto knife with a #17, #18, or #19 chisel blade. The CS2000 has double hard anodizing that is not easily penetrated, but nonetheless, care should be taken when using the Xacto knife. 5. Fold the cloth over a c...
Dieses Handbuch ist für folgende Modelle:Andere Werkzeuge - CONTECH CS2000 (474.6 kb)
Andere Werkzeuge - CONTECH CS2000-QD (474.6 kb)