Anleitung Zusammenfassung


Ensure that power to the proofer / holding cabinet is switched ‘On’. 1. Set the Function Control (2) to ‘HOLD’. The ‘Power On’ Indicator light (1) will illuminate when the Function Control (2) is in the ‘HOLD’ position. 2. Set the Thermostat Control (4) to the desired Holding Temperature. (65-85°C / 150-185°F). The Heating ‘On’ Indicator light (3) will turn ’Off’ when the cabinet has reached the set temperature. 3. Humidity Control (6). The humidity control function is not used in the ‘HOLD’ Mode. The setting on this dial will have no effect as the wet element, water level sensor and water solenoid are disabled. 4. Thermometer (7). The thermometer will give an accurate reading of the cabinet temperature to ensure that the product being held is at the correct temperature. 7 Cleaning Cleaning Guidelines Caution Always turn ‘Off’ the electrical power supply at the mains supply before commencing cleaning. This proofer / holding cabinet is not water proof. Do not use water jet spray to clean interior or exterior of the appliance. To achieve the best results, cleaning must be regular and thorough. If any small faults occur, have them looked at promptly. Don't wait until they cause a complete breakdown. NOTE: • Carefully read and follow the safety instructions on the label of the cleaning product to be used. • DO NOT use harsh abrasive scouring pads or abrasive detergents as they could damage the oven. • Ensure that any detergent or cleaning material has been completely removed after each cleaning. To keep your proofer / holding cabinet clean and operating at peak efficiency, follow the procedures shown below:- Proofer / Holding Cabinet Cleaning NOTE: • If the proofer / holding cabinet usage is very high, the cleaning procedure should be carried out on a more frequent basis. Stainless Steel Surfaces a. Clean the exterior surfaces of the proofer / holding cabinet with, a damp cloth moistened with a mild detergent solution, or a soft bristled brush. b. Hardened deposits or discolouration may require a good quality stainless steel cleaner. Always apply cleaner when the appliance is cold and rub in the direction of the grain. c. Dry all components thoroughly with a dry cloth and polish with a soft dry cloth. d. Ensure that the proofer / holding cabinet chamber is cool. Do not use wire brushes, steel wool or other abrasive materials to clean the interior of the cabinet. e. Once a week, remove the side racks and water tank and clean any build up of product from the proofer / holding cabinet interior, using a mild anti bacterial detergent and hot water solution and a soft bristled brush. f. Dry the proofer / holding cabinet thoroughly with a soft dry cloth. Side Racks a. To remove the side racks for cleaning, take hold of the centre rung of the rack and lift rack upwards. b. Pull lower rack outwards to disengage the lower rack key-holes from the lower hanger studs. Lower Hanger Studs c. Lift the rack upwards to disengage the upper rack key-holes from the upper hanger studs and lift the rack out of the proofer / holding cabinet. Lower Hanger Stud Lower Rack Keyhole Upper Rack Keyhole and Hanger Stud d. Clean the racks with a mild anti bacterial detergent and a hot water solution, using a soft bristled brush. 8 Cleaning e. Dry the racks thoroughly with a dry cloth and polish with a soft dry cloth. f. To refit the racks, engage the front and rear upper rack keyholes onto the upper hanger studs. g. Raise the rack up again slightly until the lower rack keyholes engage onto the lower studs, ensuring that the upper studs remain engaged. h. Push down on the rack to ensure that it is fully engaged onto the upper and lower hanger studs. NOTE: Ensure that the rack is securely fitted and that ALL the studs are engaged into the rack key holes. Water Tank It is recommended that this procedure is carried out once a week. Frequency of cleaning the element may be increased or decreased depending on the quantity of scale depositing on the element. a. To remove the water tank, remove the RH side rack as shown previously. b. Remove the water tank by lifting the tank off its hanger studs. Clean with warm soapy water. Rinse thoroughly and refit. Water Tank Hanger Studs Water Tank Element a. When the wet element becomes limed / scaled up, remove the water tank and clean as shown previously. Wet Element Water Level Sensor Water Inlet b. Refit the water tank and half fill with white vinegar or acetic acid, then fill to the normal level with water. Switch ‘On’ the unit, and turn the Humidity Control to ‘8’. Operate for approximately 30 minutes. c. When cooled, remove the water tank and clean the element with a damp cloth. Rinse out the water tank and refit to the unit. Door a. Wash with warm water and a mild detergent solution using a soft sponge in straight lines up and down the inner and outer surfaces of the door. Rinse with clean, warm water and dry off. b. Dry the door thoroughly with a soft dry cloth. c. Clean door glass with a conventional...

Dieses Handbuch ist für folgende Modelle:
Andere Werkzeuge - TURBOFAN P12M (1005.67 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien