Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Steren, modell 550-040

Hersteller: Steren
Dateigröße: 429.39 kb
Dateiname: b1c189ce-3346-46d3-8595-edbc0ee4ee81.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Use caution when handling this module. Be careful not to drop the module because this could affect the performance and/or damage the module. • Take extra precautions when working with cables, wires and tools. Do not install cables and wires that appear to be damaged. Avoid kinking cables and wires during installation. • Be careful when using tools that might touch exposed wires or live electrical contacts. • To prevent electric shock: 1) do not touch uninsulated wires and terminals that may still be connected to a live circuit; 2) do not install wires or electrical equipment during a lightning storm; 3) do not install wires or electrical equipment or their enclosures near water or locations where water is used (in the kitchen, bathroom, laundry room, swimming pool, etc.); 4) do not install electrical components or equipment in wet areas, unless specifically rated for moisture. • Make sure all wires in the modules are properly connected or terminated. R Fast Media Home Network Systems Revised 06/04 —2— 550-040Manual.qxd 7/6/04 3:42 PM Page 3 FastHome™ 550-040 TV Combiner/Splitter Module Installation Guide Pre-Installation Instructions 1. After the enclosure has been mounted, determine which modules will be inserted. On a sheet of paper, diagram the location where each module will be placed. An expansion module should be placed close to the module with which it interfaces. 2. On the diagram, identify the origin and destination of each cable. Make sure the module serving each device is safely within a 100ft/30m distance. Installation Instructions Note: Do not connect the DC power supply to a power outlet until all wiring has been completed. 1. Identify the enclosure location on which the module will be mounted. 2. Mount the module by inserting the nylon pins into the holes in back of the enclosure and pressing the pins in. Make sure that the pins are firmly seated and the module is secure. Wiring Instructions Note: Module wiring should only be performed by a experienced, licensed electrician. Make sure all power has been shut off to the equipment and there is no live circuit. Route all cables through the knock-out holes and bundle with tie wraps or cable straps to ensure safe and long-lasting connections. 1. Connect F-terminated coaxial cable inputs from the cable TV incoming feed and, if inserting security camera feed, the Fast Media RF Modulator Module (550-080) onto the ports on the “input” side of the TV hub. 2. Connect an F-terminated coaxial cable onto each of 1-6 outputs on the “output” side of the hub. 3. Route the cables from the hub to the TV set locations in the home and terminate with 75-Ohm F-connectors. 4. Place 75-Ohm termination caps over unused TV hub ports to improve video reception. 5. Connect the 9VDC power supply cord to the power input jack. Installation Sample configuration for telephone, audio/video, security and Ethernet. For More Information about FastHome™ and Fast Media Home Network Systems, contact: Steren Electronics International, LLC 8675 Miralani Drive San Diego, CA 92126 1-800-266-3333 Copyright © 2004 Steren Electronics International, LLC Printed in China R Fast Media Home Network Systems Revised 06/04 —3— 550-040Manual.qxd 7/6/04 3:42 PM Page 4 Fast Media Fast MediaFast Media Home Network Home NetworkHome Network Systems SystemsSystems For your future construction needs, consider the entire series of FastHome™ Enclosures and Modules. FastHome™ Enclosures From a centralized location, Fast Media Home Network Systems enclosures fully integrate, manage and distribute broadband and multimedia serv ices on a flexible, customizable and upgradeable platform. 550-100 550-105 Constructed of 18-gauge cold Small Surface Mount Enclosure Large Surface Mount Enclosure rolled steel for strength and 7.(W) x 11.(H) x 35/16.(D) 149/16.(W) x 19.(H) x 45/16.(D) protection against interference, FastHome™ enclosures mount on a wall (surface mount) or between 16. center wall studs (flush mount). FastHome™ Modules High-quality FastHome™ modules by Steren provide secure, reliable connections for voice, video, data and audio applications. Each module is housed in a sturdy 18-gauge cold rolled steel construction for excellent RFI shielding. The system is expandable by adding multiple modules. 550-210 Large Flush Mount Enclosure 14 3/8.(W) x 44.(H) x 3 1/2.(D) 550-205 Medium Flush Mount Enclosure 143/8.(W) x 32.(H) x 3 1/2.(D) 550-200 Small Flush Mount Enclosure 143/8.(W) x 19.(H) x 31/2.(D) 550-040 550-010 550-020 550-030 Fast Media Telephone/TV Hub Module Fast Media Telephone Hub Module Fast Media Data Hub Module Fast Media TV 61/2.(W) x 43/4.(H) x 1.(D) 61/2.(W) x 27/8.(H) x 1.(D) 61/2.(W) x 27/8.(H) x 1.(D) Combiner/Splitter Module 61/2.(W) x 27/8.(H) x 1.(D) 550-050 550-060 550-070 550-080 Fast Media Audio Splitter Module Fast Media Ethernet Switch Module Fast Media Power Module Fast Media RF Modulator Module 61/2.(W) x 27/8.(H) x 1.(D) 61/2.(W) x 23/4.(H) x 1.(D) 61/2.(W) x 25/8.(...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien