Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Omega, modell CNiS8

Hersteller: Omega
Dateigröße: 1.25 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Press b & c 12) Press b and c buttons to enter your new “ID Code” number. Press d 13) Display shows STRD stored message momentarily and then advances to the FULL Full Security Submenu. FULL SECURITY LEVEL SUBMENU: Press d 14) Display flashes ENBL Enable or DSBL Disable. Press b 15) Scroll through the available selections: “Enable” or “Disable”. Press d 16) Display shows STRD stored message momentarily and then advances to SP.ID Setpoint/ID Submenu. If "Full" Security Level is "Enabled" and the user attempts to enter the Main Menu, they will be prompted for an ID Code. The ID Code should be correct to enter the instrument Menu item. SETPOINT/ID SECURITY LEVEL SUBMENU: This Security Level can be functional only if FULL Security Level is Disabled. Press d 17) Display flashes ENBL Enable or DSBL Disable. Press b 18) Scroll through the available selections: “Enable” or “Disable”. Press d 19) Display shows STRD stored message momentarily and then advances to COMM Communication Submenu. If "Setpoint/ID" Security Level is "Enabled" and the user attempts to advance into the CNFG Configuration Menu, he will be prompted for ID Code number. The ID Code should be correct to proceed into the Configuration Menu, otherwise display will show an Error and skip to the Run Mode. If “Full” and “Setpoint/ID” Security Levels are "Disabled", the ID code will be “Disabled” and user will not be asked for ID Code to enter the Menu items (“ID” Submenu will not show upin “ID/Setpoint” Menu). 49 3.2.15 Communication Option Menu Purchasing the controller with Serial Communications permits an instrument to be configured or monitored from an IBM PC compatible computer using software available from the website listed on the cover page of this manual or on the CDROM enclosed with your shipment. For complete instructions on the use of the Communications Option, refer to the Serial Communications Reference Manual. * Valid only for -C24 and -EI options. ** Valid only for -C24 and -C4EI options. Figure 3.13 Flow Chart for Communication Option Menu 50 ENTER COMMUNICATION OPTION MENU: Press a 1) Press a, if necessary, until CNFG prompt appears. Press d 2) Display advances to INPT Input Menu. Press a 3) Press a, if necessary, until display advances to COMM Communication Options Menu. Press d 4) Display advances to C.PAR Communication Parameters Submenu. If Communication Option is not installed, the display shows NONE and skips to the Color Display Menu. COMMUNICATION PARAMETERS SUBMENU: Allows the user to adjust Serial Communications Settings of the instrument. When connecting an instrument to a computer or other device, the Communications Parameters must match. Generally the default settings (as shown in Section 5) should be utilized. Press d 5) Display advances to BAUD Baud Submenu. BAUD SUBMENU: Press d 6) Display flashes previous selection for BAUD value. Press b 7) Scroll through the available selections: 300_, 600_, 1200_, 2400_, 4800_, 9600_, 19.2K. Press d 8) Display shows STRD stored message momentarily and then advances to PRTY only, if it was changed, otherwise press a to advance to PRTY Parity Submenu. PARITY SUBMENU: Press d 9) Display flashes previous selection for “Parity”. Press b 10) Scroll through the available selections: NO, ODD, EVEN. Press d 11) Display shows STRD stored message momentarily and then advances to DATA only, if it was changed, otherwise press a to advance to DATA Data Bit Submenu. DATA BIT SUBMENU: Press d 12) Display flashes previous selection for “Data Bit”. Press b 13) Scroll through the available selections: 7-BIT, 8-BIT. Press d 14) Display shows STRD stored message and then advances to STOP only, if it was changed, otherwise press a to advance to STOP Stop Bit Submenu. 51 STOP BIT SUBMENU: Press d 15) Display flashes previous selection for “Stop Bit”. Press b 16) Scroll through the available selections: 1-BIT, 2-BIT. Press d 17) Display shows STRD stored message momentarily and then advances to BUS.F only, if it was changed, otherwise press a to advance to BUS.F Bus Format Submenu. BUS FORMAT SUBMENU: Determines Communications Standards and Command/Data Formats for transferring information into and out of the controller via the Serial Communications Bus. Bus Format submenus essentially determine how and when data can be accessed via the Serial Communications of the device. Press d 18) Display advances to M.BUS Modbus Submenu. MODBUS PROTOCOL SUBMENU: Press d 19) Display flashes previous selection for M.BUS. Press b 20) Scroll through the available selections: NO, YES. Press d 21) Display shows STRD stored message momentarily and then advances to _LF_ only, if it was changed, otherwise press a to advance to _LF_ Line Feed submenu. To select iSeries Protocol, set Modbus submenu to “No”. To select Modbus Protocol, set Modbus submenu to “Yes”. If Modbus Protocol was selected, the following Communications Parameters must be set as: No Parity, 8-bit Data Bit, 1-Stop Bit. Do not attempt to change these parameters....

Dieses Handbuch ist für folgende Modelle:
Andere Werkzeuge - CNiS16 (1.25 mb)
Andere Werkzeuge - CNiS8DH (1.25 mb)
Andere Werkzeuge - CNiS8DV (1.25 mb)
Andere Werkzeuge - CNiS16D (1.25 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien