Login:
Stimmen - 4, Durchschnittliche Bewertung: 5 ( )

Anleitung Lennox Hearth, modell SHADOWDANCE LSVFSD-24

Hersteller: Lennox Hearth
Dateigröße: 1.74 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Check Gas Type This appliance can only be connected to the gas type specified on the appliance rating plate. This appliance can not be modified in the field for a different gas type. If the gas supply differs, DO NOT INSTALL the appliance. Contact your dealer to obtain the correct appliance. CLEARANCES WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the build ing is of unusually tight construction, you must provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section on Air for Combustion and Ventilation or applicable local codes. PREINSTALLATION WARNING Do not install this gas appliance: • In sleeping quarters, bathrooms, or a recreational vehicle. • Wherecurtains,furniture,clothingorotherflammable objects are less than 42" from the front of the gas appliance. • In high traffic areas. • In windy or drafty areas. WARNING Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. CAUTION Appliances create warm air currents. These currents move heat to wall surfaces next to appliance. Install ing appliance next to vinyl or cloth wall coverings or operating appliance where impurities in the air (such as tobacco smoke) exists, may discolor walls. VENT FREE APPLICATIONS WHEN INSTALLED IN A VENT-FREE FIREBOX, IF THE CLEARANCES SHOWN ON PAGES 7 & 8 OF THIS MANUAL ARE GREATER THAN THE CLEARANCES FOR THE VENT-FREE FIREBOX, THE LESSER CLEARANCES OF THE VENT-FREE FIREBOX APPLY. ensure the minimum clearances shown in Figures 2 through 8 are maintained. left and right clearances are determined when facing the front of the appliance. Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fire hazard. Step 1. Sidewall Clearances: the sides of the fireplace opening must be at least 16" from any combustible side wall (Figure 2). Note: Diagrams aND illustratioNs are Not to scale. 7 Figure 3 Step 2. Ceiling Clearance: the ceiling must be at least 42" from the top of the appliance opening (Figure 2). Step 3. Noncombustible materials (minimum requirements): to install the appliance without wood mantels, shelves or other combustible projec- tions directly above the opening of the fireplace (firebox) refer to Figure 3 and Table 1. Note that at least 8" of noncombustible material must be installed above the appliances described in this manual. Noncombustible materials, such as slate and marble, must be at least 1/2" thick. Figure 4 16" Min. 42" Min. Figure 2 - Clearances Noncombustible Material 8" or More of Noncombustible Material Appliance in Fireplace or Firebox Appliance in Fireplace or Firebox Adjustable Canopy A Step 4. Wood mantel, shelf or combustible projection requirements: to install a wood mantel, shelf or other combustible projection directly above the fireplace (firebox), refer to Table 2 and to Figures 5 and 6 for installation profiles. if your mantel profile is unsafe, you may either: • raise the mantel to an acceptable height, or • remove the mantel. Example: The bottom of the mantel may project from the wall a maximum of 2-1/2" at a minimum of 28" above the opening. The top shelf of the mantel may project a maximum of 6" at a minimum of 34-1/2" above the opening. NoncombustibleMaterial12" 28" 34-1/2" 38-5/8" 42" 10" 2-1/2" 6" 8" CeilingFigure 5 Noncombustible Material Requirements with No Mantel Installed (A) Noncombustible Material Measurement Requirements for Safe Installation 12" or more adjustable canopy not required. 8" minimum to 12" install adjustable canopy. less than 8" extend noncombustible material to at least 8" and install adjustable canopy (Figure 4). or extend noncombustible material to a height of at least 12". Table 1 Noncombustible Material Heights and Mantel Location (A) Noncombustible Material Measurement Requirements for Safe Installation with Wood Mantel, Shelf or Other Combustible Projection 12" or more adjustable canopy not required. observe profiles shown in Figure 5. 8" minimum to 12" install adjustable canopy and observe profiles shown in Figure 4. or extend heat resistant material to at least 12" and observe profiles shown in Figure 3 and 5. Table 2 8 Note: Diagrams aND illustratioNs are Not to scale. any outside air ducts and/or ash dumps in the fireplace shall be perma- nently closed at time of appliance installation. a qualified gas appliance installer must install this dual-listed appli- ance. Check gas type: The gas supply must be the same as stated on the appliance’s rating plate. If the gas supply is different, DO NOT INSTALL the appliance. Contact your dealer for the correct model. Step 1. Unpack Appliance -remove appliance from carton. cut tie-wires holding ember bed rear log to the base. unwrap foam packaging from ember bed rear log. Step 2. Placement of Appliance – center...

Dieses Handbuch ist für folgende Modelle:
Andere Werkzeuge - SHADOWDANCE LSVFSD-18 (1.74 mb)
Andere Werkzeuge - SHADOWDANCE LSVFSD-NG (1.74 mb)
Andere Werkzeuge - SHADOWDANCE LSVFSD-30 (1.74 mb)
Andere Werkzeuge - SHADOWDANCE LSVFSD-LP (1.74 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien