Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Crestron electronic, modell GLS-ODT-C-500. GLS-ODT-C-1000

Hersteller: Crestron electronic
Dateigröße: 706.31 kb
Dateiname: io_gls-odt-c-500_1000_2000.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Option B. Drop Ceiling Installation Using Screws (Cont’d) Option C. Back Box or Surface Mount Raceway Installation Drop Ceiling Mounting to Octagon Back Box Installed Flush to Drop Ceiling GLS-SIM Cresnet® GLS-ODT-C-500/1000/2000 Up to Three in Parallel The supplied masks mount in the sensor front cover. The half mask is supplied pre-mounted to demonstrate the mounting method. The perforated mask has twelve 30. removable segments that allow you to mask particular areas to prevent undesireable triggers from affecteng the sensor operation. The following illustrations provide typical application examples. 1. Select the location for mounting of the sensor and proper masking for your application (Refer to Mounting/Masking Location Diagram). 2. Refer to the suggested mounting option illustrations below. Mounting to Round Fixture with Raceway for Wallboard Ceiling Installation DIN-IO8 GLS-ODT-C-500/1000/2000 Cresnet® GLS-SIM (Optional) Crestron 2-Series Control Processor or CLS-C6 Crestron 2-Series Control Processor Option A. Drop Ceiling Installation Using Supplied Threaded Rod MOUNTING/MASKING LOCATION DIAGRAM TYPICAL APPLICATION DIAGRAMS SPECIAL PROGRAMMING #8-32 Screws (2 places) Octagon Back Box 4" x 1 1/2" deep Low-Voltage Wires GLS-SIM (Optional) Low-Voltage Wires Wallboard Ceiling GLS-SIM (Optional) Wire Mold Back Cover Back Cover Screws (4 places) Wire Mold Round Fixture (for raceway mount) Mounting Screws (4 places) Wire Mold Raceway (use applicable fittings) . 0 20 11.5 11.5 8.5 8.5 20 TOP VIEW SIDE VIEW 0 20 11 15 17 23 3 5.6 9 8 0 Minor Motion, Ultrasonic Major Motion, Ultrasonic Major Motion, IR Field-of-View Ranges - GLS-ODT-C-500 0 20 11.5 11.5 8.5 8.5 20 SIDE VIEW TOP VIEW 23 17 17 23 8 0 20 15 11 9 5.6 3 0 3 5.6 9 11 15 20 Minor Motion, Ultrasonic Major Motion, Ultrasonic Major Motion, IR 0 20 8 16 16 11.5 11.5 20 SIDE VIEW TOP VIEW 20 15 11 9 5.5 3 0 3 5.59 11 15 20 32 22.5 22.5 32 Minor Motion, Ultrasonic Major Motion, Ultrasonic Major Motion, IR Adjustment Knob Settings KNOB COLOR FUNCTION Sets the ultrasonic range Sets the infrared range Delayed- Off Time Ambient Light Override (Gray wire only) KNOB SETTING Range setting Full CCW = min. (OFF) Full CW = max. Range setting Full CCW = min. (OFF) Full CW = max. Full CCW = min. (30 sec.) Full CW = max. (30 min.) DEFAULT SETTING 75% 50% 100% Full CCW – Lights stay OFF Full CW – Lights always turn ON (NO ambient light override) Range– 100-3000 LUX 50% (10 min) Blue Black Red Green SYMBOL A B ON ON 1 1 A B ON ON 1 1 Minimum and Default Settings Minimum Setting Factory Default Setting MIN MAX Adjust Knob Rotation Direction DIP Switches 30 sec 5 min 30 min 20 min 10 min Delayed Off Time Selection (Black Knob) B3 • Dual-Tech Mode. This is the default mode of operation for the sensor. Passive infrared technology (PIR) turns lights on in this mode; however, motion detection by either technology (PIR or ultrasonic) will keep the lights on. If neither technology detects motion, the lights turn off after the delayed-off time. • Single-Tech Mode. Only one technology is active in this mode. The technology is selected by the dip switches. Motion detection by the selected technology - PIR or ultrasonic - will turn on the lights as well as keep them on. When motion is not detected, the lights will turn off after the delayed-off time. • Delayed-Off Time. The sensor is designed to turn the lights off if no motion is detected after a specified time. This length of time is called the delayed-off time and is set using the timer (black) knob on the sensor. The adapting patterns will modify the delayed-off time to fit the parameters of each installation based on environmental conditions and occupancy patterns. • Walk-through Mode. The walk-through feature is useful when a room is momentarily occupied. With this feature, the sensor will turn the lights off shortly after the person leaves the room. The walk-through feature works as follows: When a person enters the room, the lights will turn on. If the person leaves the room before the walk-through time-out of 2.5 minutes, the sensor will turn the lights off. If the person stays in the room for longer than 2.5 minutes, the sensor will proceed to the Occupied mode. • LED Operation. There are two LED indicators that will flash when motion is detected. The LED flash can be disabled using the LED disable switch setting. Green flashes indicate motion detection by ultrasonic technology. Red flashes indicate motion detection by infrared technology. The sensor continually analyzes the parameters of the motion detection signal and adjusts its internal operation to maximize detection of motion while minimizing the effects of noise (electrical noise, air currents, temperature changes, etc.). Operation When the lights turn on, the sensor initially begins the Walk-through mode. Once the room is occupied for longer than 2.5 minutes, the sensor ends the Walk-through mode and begins the Occupied mode. When the sensor is first installed, ...

Dieses Handbuch ist für folgende Modelle:
Andere Werkzeuge - GLS-ODT-C-2000 (706.31 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien