Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Crestron electronic, modell Dual-Technology Wall Mounted Occupancy Sensor GLS-ODT-W-1200

Hersteller: Crestron electronic
Dateigröße: 657.91 kb
Dateiname: io_gls-odt-w-1200.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Other methods may be possible but they are not described here. Parts Supplied Sensor (1) #8-32 x 1/2" screw (2) #8-32 x 1-1/2" screw (2) #8x32 Washer and Nut (2) Tools/Equipment Required (not supplied) Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Diagonal Cutters Model/Features The Occupancy Sensor is a low-voltage infrared and ultrasonic sensor that works with the GLS-SIM (or other compatible interface) to automatically control lighting. The exact behavior of the sensor can be configured via software, but the sensor is typically used to turn lights on when a room or area is occupied, and to shut them off when the room or area is vacated. The sensor continually analyzes and adjusts to changing conditions. The sensor uses the latest microprocessor-based technology which permits it to continually adjust and optimize its performance. The combination of ultrasonic (doppler shift) motion detection, which gives maximum sensitivity, and infrared motion detection, which gives higher false triggering immunity, yields a sensor with excellent performance. Crestron GLS-ODT-W-1200 Dual-Technology Wall Mounted Occupancy Sensor Operations & Installation Guide Coverage 1200 sq. ft (111.48 sq. m) Suggested Mounting Location Mount in corner/ over doorway Model No. GLS-ODT-W-1200 Description 1-Way Dual-Technology Operating Frequency 32KHz Current Consumption 30mA Mounting to Drop Ceiling Using Screws, Nuts, and Washers Option A. Wallboard or Drop Ceiling Installation Using Screws NOTE: You may use the mounting screws, nuts and washers included, or screws in combination with commercially available wall anchors. 1. Select the location for mounting of the sensor for your application. (Refer to Mounting Location Diagram). 2. Make a hole in the wallboard or ceiling tile large enough to pass the wire connections and wire nuts through (approximately 1" [26 mm] diameter). 3. Drill holes for monting screws using mounting bracket as a guide. 4. Install the mounting bracket of the wall sensor to the wallboard or ceiling using the included screws, nuts and washers. 5. Pass wires through the base cover/neck assembly. (Refer to the suggested mounting option illustrations below.) 6. Connect low voltage wires from the GLS-SIM or other Crestron® device as shown in the wiring diagram. Twist strands of each lead tightly and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure that no bare conductor shows below the wire connectors. Secure each connector with electrical tape. 7. Push wire connections through the center hole of the back cover and into the wall or ceiling. 8. Snap neck and base cover onto mounting bracket in the desired orientation. 9. Push wires through the hole and begin to fasten the plastic nut around the back of the sensor body. Move the sensor body to the desired orientation and then continue to tighten the nut around the sensor body. 10. Restore power at the circuit breaker or fuse. INSTALLATION IS COMPLETE. Option B. Wallboard or Drop Ceiling Installation Using Back Box Option C. Surface Mount Raceway Installation Mounting to Octagon Back Box Installed Flush to Drop Ceiling TYPICAL APPLICATION DIAGRAMS Up to Three in Parallel The following illustration provides a typical application example. 1. Select the location for mounting of the sensor for your application. (Refer to Mounting Location Diagram). 2. Refer to the suggested mounting option illustrations below. Mounting to Round Fixture with Raceway for Wallboard Ceiling Installation GLS-ODT-W-1200 GLS-SIM (Optional) Mounting to Wallboard Using Screws Low-Voltage Wires Drop Ceiling Sensor Base Cover Screw, Nut and Washer (2 places) Plastic Nut Mounting Base Mounting Screws (2 places) Mounting Base (top view) Low-Voltage Wires Wallboard Base Cover/ Neck Assembly Sensor Plastic Nut Mounting Screws (2 places) 4" Octagon Raised Cover 4" Octagon Raised Cover Mounting Base Octagon Box 4" 1 1/2" deep Wallboard Ceiling Mounting to Octagon Back Box Installed Flush to Wallboard Octagon Box 4" 1 1/2" deep Mounting Screws Wallboard (2 places) Wallboard Mounting Screws for Wire Mold Fixture (2 places) Wire Mold Round Fixture Wire Mold Back Cover Wire Mold Raceway GLS-ODT-W-1200 GLS-ODT-W-1200 GLS-SIM (Optional) GLS-SIM (Optional) GLS-SIM (Optional) GLS-SIM Cresnet® DIN-IO8 Cresnet® Crestron 2-Series Control Processor or CLS-C6 Crestron 2-Series Control Processor Sensor #1 24 1 2 G optional Sensor #2 ( ) Red Black Black Red Red * Blue* Sensor #1 Black Red Blue2 Connecting Sensors to the GLS-SIM Connecting Sensors to the DIN-IO8 or Equivalent1 * To incorporate the internal photocell, connect gray wire to GLS -SIM and cap off blue wire from sensor. Gray 2 (cap off) Gray* (cap off) ––– NET––– –SENSOR– 24 Y Z G Use CRESNET-P or CRESNET-NP wire only GLS-SIM Sensor #1 optional Sensor #3 ( ) To Control System G 1 2 3 4 ––– NET G 1 2 3 4 24 Y Z G 24 Y Z G ––– To Control System ––– I/O ––– DIN-IO8 NOTE: The same Crestron po...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien