Anleitung Bryant, modell GAS FIRED 394U
Hersteller: Bryant Dateigröße: 120.36 kb Dateiname: pds394u.80.2.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Same as D4 except uses thermocouple pilot and pilot relay. HEATING RATINGS AND CAPACITIES Rating1 Input2 BTUH 80,000s Output BTUH 64,000 Ratings are for elevations up to 2000 ft.; for higher altitudes, reduce ratings 4 % for each 1000 ft. above sea level. 220% reduction in input allowed. 3For LP Gas, model designated 80-V-394, A.G.A. Input 75,000, Output 60,000. -minimum cooling -minimum cooling with L —Multi-speed direct drive heating-M—Multi-speed direct drive heating-evaporator blower motor relay E —Multi-speed direct drive heating—cooling with evaporator blower motor relay,. Gas Supply NP%T N^6ralS. ^ 1 * VPrlpane H*# » гл Electric Supply—SDirset E$©vt|i >20.-60-1 Branch Circuit AWG/' Fuse Size f 15^Д Control Circuit Power AggiE *^ V i V*1 Type L \ \ Vw' кМо.Г'Д Type M or E \ v" ' Flue Size \ \'"j3 ^4 (Oval) Duct—Inlet at bottom \V ^ 22И x 12M Inlet ext. filter rack ' H x W 12 x 23 Inlet drop duct D x W 12 x 14M Discharge D x W 20 x UVs *External to unit COMPONENT INFORMATION CONTROL INFORMATION Motor—Type L or M—4 Speed Vs HP (Sh. Pole) Power Supply 120-60-1 Full Load Amps_ 6.3 Speed & Rotation 1050 CCW* Motor—Type E—4 Speed M HP (PSC) Power Supply 120-60-1 Full Load Amps 5.4 Speed & Rotation 1075 CCW* Blower Wheel Dia. & Width 10" x 6" Bore—Direct Drive У2" Filter—Fiberglass * * Inlet At Bottom 14" x 25" x 1" External Filter Rack 14" x 25" x 1" Internal Side Filter 14" x 25" x 1" Rear Drop Duct 14" x 25" x 1" *Rotation viewed from end opposite shaft **Use multi-velocity filters above 875 CFM Burners (Steel Slotted Port) 3 Orifice Drill Size Prop. 54 Nat. 40 D2 Control (Prop.) Regulator None Required Valve , K A641 Escapement Orifice Drill Size 180 Pilot—MH Q314A .011 Orifice D4 Control (Nat.) Regulator Comb. Thermae J-i VR-1 Valve ^ A641 Escapement Orifice Drill Size 80 Pilot—732 .016 Orifice D5 Control (Nat.) Regulator Comb. Thermae 34 VR-1 Valve A641 Escapement Orifice Drill Size 80 Pilot—MH Q314A .018 Orifice . Manual Shut-off Cock and Pilot Cock are standard equipment. Supplied as separate parts except where included as integral part of the combination regulator. Optional External Filter Rack Mounts on Either Side AIR FLOW FOR INDICATED AIR TEMPERATURE RISE* TEMP RISE °F 70 75 80 85 90 95 100 AIR FLOW CFM 795 741 695 654 618 585 556 *At Rated Input FRONT I OF I FURNACE T T” 12 14 11 REAR OF FURNACE FILTER SERVICE L2 ACCESS li" L -23- 25 AIR DELIVERY PERFORMANCE J Air Delivery CFM EXTERNAL STATIC PRESSURE AVAILABLE Type L or M Motor Type E Motor Hi Med Med-Lo Lo Hi Med Med-Lo Lo 500 .88 .78 .70 .58 .77 600 .76 .65 .52 .06 .61 700 .63 .47 .78 .27 800 .48 .60 900 .16 .74 .33 1000 .76 .58 1100 .63 .38 1200 .46 .14 1300 .27 1400 .07 Above data gives Cfm under typical field applications (i.e. 125 volts). LINE-TO-LINE SCHEMATIC UNIT WIRING DIAGRAMS Type L Types M or E PDS 394U.80.2 -2-...