Login:
Stimmen - 5, Durchschnittliche Bewertung: 4 ( )

Anleitung Elation Professional, modell Landscape Lighting

Hersteller: Elation Professional
Dateigröße: 1.88 mb
Dateiname: design-wash-led-pro-maunal.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


40 Channel 12 - Speed pan/tilt movement: 0-225 Max to min speed 226-235 Blackout by movement 236-255 No function Channel 13 – reset, Internal programs: 0-79 Normal 80-84 All motor reset 85-87 Scan motor reset 88-99 No function 100-119 Internal program 1 (secne1~8 of EEPROM) 120-139 Internal program 2 (secne9~16 of EEPROM) 140-159 Internal program 3 (secne17~24 of EEPROM) 160-179 Internal program 4 (secne25~32 of EEPROM) 180-199 Internal program 5 (secne33~40 of EEPROM) 200-219 Internal program 6 (secne41~48 of EEPROM) 220-239 Internal program 7 (secne49~56 of EEPROM) 240-255 Music Control (scene of Program 1) Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. 41 14. ERROR CODES: When power is applied, the unit will automatically enter a “reset/test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors an error code will flash in the display in the form of “XXer” were as XX will represent a function number. For example, when the display shows “0Er,” it means there is some type of error with the Pan motor. If there are multiple errors during the start-up process they will all flash in the display. For example: if the fixtures has errors on channel 1, channel 2, and channel 5 all at the same time, you will see the error message “01Er”, “02Er,” and ”05Er” flash repeated 5 times. If an error does occur during the initial start-up procedure the fixture will self-generate a second reset signal and try to realign all the motors and correct the errors, if the error persist after a second attempt a third attempt will be made. If after a third attempt all the errors have not been corrected the fixture will make the following determinations: 1) 3 or more errors - The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand-by mode until subsequent repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors, therefore most other functions will work properly. The fixture will attempt to operate normally until the errors can be correct by a technician. The errors in question will remain flashing in the display as a reminder of internal errors. PAN Error: The yoke is not located in the default position after start-up or after a reset command. This message will appear after a fixture reset if the pan’s magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective motor or a defective motor IC drive on the main PCB). This error may also be displayed if the head/yoke was blocked during a reset function. TILT Error: This message will appear after a fixture reset if the tilt’s magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective motor or a defective motor IC drive on the main PCB). This error may also be displayed if the head was blocked during a reset function. Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. 42 15. CLEANING AND MAINTENANCE The following points have to be considered during the inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. There must not be any deformations on the housing, lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Damaged rigging points or unsecured rigging could cause the unit to fall and serious injure a person. 3. All mechanical parts and motors should not show any traces of serious wear and should rotate freely. 4. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable. Further instructions depending on installation and usage have to be adhered by a skilled installer and any safety problems should be addressed before attempting operation. Disconnect from mains before starting maintenance operation. We recommend frequent cleaning of the fixture to ensure operational longevity and crisp light output. When cleaning, please use a moist, lint-free cloth. Never use alcohol or solvents. There are no user serviceable parts inside this fixture with the exception of the lamp. Please refer all other service related issues to an authorized Elation service technician. Should you decide to service the fixture yourself please order genuine Elation parts directly from Elation. Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. 43 16. PHOTOMETRIC DATA: Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. 44 17. DIMENSIONAL DRAWINGS: Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. 45 18. CIRCUIT SCHEMATICS Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. 46 19. 2-YEAR LIMITED WARRA...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien