Anleitung Zusammenfassung


8. Resecure arm cap with arm cap set screws tightened to 50 in/lbs. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-575 AVU040300 Fixture Screws Fig. 1 Teflon Washers Arm Cap Arm Cap Set Screws Set Screws Bishop Arm Aligning Pin Aligning Socket Fig. 2a Modern Top Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-575 AVU040300 Epic/Pole Mounted Fixtures Sheet 2 of 4 2/18/04 IMI-575 INSTALLATION INSTRUCTIONS IMPORTANT: Read carefully before installing fixture. Retain for future reference. TM FIXTURE MAINTENANCE A. Relamping Horizontally lamped 1. Loosen two door screws. 2. Lower door to tethered resting position. See Figure 4. 3. Install suitable lamp. Consult re-lamp label and lamp instructions for details. Do not overtighten. 4. Raise door and secure with screws. Vertically lamped 1. Loosen and remove ring retaining screws globe retaining ring and globe. Components are not tethered. See Figure 5. 2. Install suitable lamp. Consult re-lamp label and lamp instructions for details. Do not overtighten. 3. Reinstall ring retaining screws securing globe retaining ring and globe. In the case of type 3 refractive glass globe, use the mark on globe bottom for orientation. B. Starter and Fuse Replacement (Where applicable) Horizontally lamped 1. Loosen two door screws. 2. Lower door to tethered resting position. See Figure 4. 3. Loosen thumbscrew until rectangular washer can be rotated 90 degrees. See Figure 6. 4. Rotate reflector faceplate to release from screws using key hole slots. 5. Unplug optic quick-disconnect. 6. Remove two screws on ballast cover followed by ballast cover. See Figure 7. 7. For starter replacement, remove the plug-in starter from receptacle and replace. For fuse replacement, unscrew fuse holder cap and replace fuse. Resecure fuse holder cap. 8. Resecure the ballast cover with the two screws. 9. Plug optic quick-disconnect and secure reflector by keyhole slots and thumbscrew. 10. Raise door and secure with screws. Aligning Socket Fig. 2b Aligning Pin Classical Top Fixture Screws Teflon Washers Fig. 3 Arm Cap Arm Cap Arm Cap Set Screws Traditional Arm Door Screws Fig. 4a Options FG, FR, SG & FRS These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-575 AVU040300 Epic/Pole Mounted Fixtures Sheet 3 of 4 2/18/04 IMI-575 INSTALLATION INSTRUCTIONS IMPORTANT: Read carefully before installing fixture. Retain for future reference. TM WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. Vertically lamped 1. Loosen and remove ring retaining screws globe retaining ring and globe. Components are not tethered. See Figure 5. 2. Remove two screws on ballast cover followed by ballast cover. See Figure 7. 3. Unplug optic quick-disconnect. 4. For starter replacement, remove the plug-in starter from receptacle and replace. For fuse replacement, unscrew fuse holder cap and replace fuse. Resecure fuse holder cap. 5. Plug optic quick-disconnect. 6. Resecure the ballast cover with the two screws. 7. Reinstall ring retaining screws securing globe retaining ring and globe. In the case of type 3 refractive glass globe, use the mark on globe bottom for orientation. C. Power Pack Replacement Horizontally lamped 1. Loosen two door screws. 2. Lower door to tethered resting position. See Figure 4. 3. Loosen thumbscrew until rectangular washer can be rotated 90 degrees. See Figure 6. 4. Rotate reflector faceplate to release from screws using key hole slots. 5. Unplug optic quick-disconnect. 6. Remove two screws on ballast cover followed by ballast cover. See Figure 7. 7. Unplug service quick-disconnect. 8. Holding the handle, loosen the two screws holding the power pack to the fixture housing. See Figure 8. 9. Holding the handle, rotate the power pack until free and lower. 10. Holding replacement power pack by handle, raise onto screw heads and rotate. 11. Tighten the two screws while holding power pack in position. 12. Plug together the service quick-disconnect. 13. Resecure the ballast cover with the two screws. 14. Reconnect optic quick-disconnect and secure reflector by keyhole slots and thumbscrew. 15. Raise door and secure with screws. Tether Door Screws Fig. 4b Options FG, FR, SG & FRS Ring Retaining Screws Fig. 5a Globe Retaining Ring Globe Option MA Ring Retaining Screws Fig. 5b Globe Retaining Ring Globe Options 3R & 5R These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, oper...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien