Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Kohler, modell Thermostatic Electric Shower

Hersteller: Kohler
Dateigröße: 1.36 mb
Dateiname: 40d61be4-7eca-47b3-b6a1-bf2d67be71fe.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Having done so, keep it handy for future reference. The Mira Azora is a thermostatic electric shower with separate controls for power selection and temperature/flow adjustment. A unique thermostatic valve stabilizes temperature changes caused by water pressure fluctuations. These can result from taps being turned on or off, or a toilet being flushed. An individual light indicates “ON/OFF”. The Mira Azora comes complete with a set of Mira Energise Shower Fittings. Mira Azora 9.8 kW A 9.8 kW 240 V AC (9.0 kW 230 V AC) heater with Mira Azora adjustable spray handset with four different spray actions (start, soothe, force and eco*). Supplied complete with flexible hose, clamp bracket assembly, slide bar, supports, hose retaining ring and soap dish. Available in a satin chrome and glass finish. * The eco setting reduces the water flow to give economical use of water, whilst still giving an adequate shower performance. This setting performs best with most gravity, pumped, and mains pressure unvented systems. On electric showers and some combination boiler systems the economy setting will have no effect, and will give the same spray action as the start setting. Patents and Design Registration Design Registration: 000578463-001-002 Patents: GB2341667, Ireland 82835 Patent Applications: GB0612240.2, GB0415901.8, Ireland 2006/0462 If you experience any difficulty with the installation or operation of your new shower, then please refer to the Fault Diagnosis section, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found on the back cover of this guide. Important Safety Information Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. Warning! Follow all warnings, cautions and instructions contained in this guide, and on or inside the appliance. 1. Products manufactured by us are safe and risk-free, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations. 2. Isolate the electrical and water supplies before commencing installation. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable. 3. Mains connections are exposed when the cover is removed. 4. Refer to the wiring diagram before making any electrical connections (see internal wiring diagram at the back of the book). 5. Make sure that any pipework that could become frozen is properly insulated. 6. Having completed the installation, make sure that the user is familiar with the operation of the appliance. 7. Make sure that this guide is left with the user. 8. DO NOT commission this appliance if water leaks from the unit or the heater tank pressure relief valve. 9. DO NOT fit any form of outlet control (e.g. Trigger handset) as the outlet acts as a vent for the tank body. Only Mira recommended outlet fittings should be used. 10. Ensure all electrical connections are tight, to prevent overheating. 11. Warning! DO NOT operate this appliance if it is frozen. Allow the appliance to thaw before using. The shower unit must not be fitted where it may be exposed to freezing conditions. 12. This product is not suitable for areas with high humidity (i.e. steam rooms). Please consult your installer. 13. THIS APPLIANCE MUST BE EARTHED. ENSURE SUPPLEMENTARY BONDING COMPLIES WITH THE “REQUIREMENTS FOR ELECTRICAL INSTALLATIONS”. In accordance with the current edition of “The Plugs and Sockets etc. (Safety) Regulations” in force at the time of installation, this Mira Escape is intended to be permanently connected to the fixed electrical wiring of the mains system. Caution! 1. Read all of these instructions and retain this guide for later use. 2. The electrical installation must comply to “BS 7671 - Requirements for Electrical Installations”, commonly referred to as the IEE Wiring Regulations - Part 7, or any particular regulations and practices, specified by the local electricity supply company. 3. The plumbing installation must comply with the requirements of UK Water Regulations/Bye-laws (Scotland), Building Regulations or any particular regulations and practices, specified by the local water company or water undertakers. 4. Make sure that you fully understand how to operate this shower and make sure that it is properly maintained in accordance with the instructions given in this manual. 5. Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to: The young, the elderly, the infirm, the disabled, anyone who suffers from a medical condition that can result in temporary incapacity (e.g. epilepsy or blackouts), anyone inexperienced in the correct operation of the controls. 6. Sunburn or skin conditions can increase your sensitivity to hot water. Make sure that you set the shower to a cooler temperature. 7. If any of the following conditions occ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien