Anleitung Saunatec, modell Infared Wooden Sauna Room IG-570G
Hersteller: Saunatec Dateigröße: 400.55 kb Dateiname: 53fa96c3-100d-45fb-bdaf-29e20659cc9e.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
.When using an electrical appliance, basic precautions should always be followed, including the following: DANGER To reduce the risk of burns, fire, electric shock, or injury to persons. .Connect the power cord to a properly grounded outlet only. .Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. .Keep the electrical cord away from heated surfaces. .Heaters shall not be subjected to water spray; shower heads shall not be installed within the sauna room. .If the temperature limiting control reset switch trips frequently, a qualified service person should be contacted. .Never operate this appliance if it has a damaged cord or plug, if it is not working properly, or if it has been dropped or damaged. For technical support or questions on operating the sauna please call the Saunatec National Customer Service Center toll-free at (888) 780-4427; or email the Service Center at techsupport@saunatec.com. WARNING .If you have any health problem or condition, consult your physician for permission to use the sauna room. (“health problem”includes but is not limited to: acute diseases, malignant tumors, high blood pressure, heart disease, allergic dermatitis, pregnancy, etc.) .The sauna room should not be used by children. .Should you have any abnormal feeling with your body while using the sauna, immediately exit the sauna. .If you feel uncomfortable while using the sauna, stop immediately and consult with your doctor. .The use of alcohol, drugs, or medication is capable of greatly increasing the risk of fatal hyperthermia. .Discontinue use if nervousness, tremor, headache, feeling of sickness or nausea occurs. HYPERTHERMIA Prolonged exposure of the user in the sauna room is capable of inducing hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include: a) Failure to perceive heat b) Failure to recognize the need to exit the room c) Unawareness of impending heat d) Fetal damage in pregnant women e) Physical inability to exit the room f) Unconsciousness IG-570G-1 1 25/10/2007 PARTS NAMES IG-570G-1 2 25/10/2007 INSTALLATION OF SAUNA ROOM BODY 1. Place the floor panel in the desired location on a level surface (Note: The floor panel must be level before installing wall and ceiling panels. If the surface is not level you may need to shim the bottom panel to get level.) . Make sure lines of the flooring of the floor panel are parallel with the front wall. 2. Place the right back panel on the floor panel. . The right back panel must be held by people. 3. Place the left back panel on the floor panel. . The right back panel must be held by people. . Push the left back panel tight to the back panel. IG-570G-1 3 25/10/2007 4. Place the right side panel and the left side panel on the floor panel. . Make sure the left/right side panels and left/ right back panels are tightly fixed. 5. Place the bench support panel first and then place the bench surface panel into the sauna room. . On larger sauna rooms with more than one bench, rotate the wooden bench supports away from the side walls. . The side with Heating Film should be faced outside. . Make sure the two side slots of the long & short bench support panel are inserted into the corresponding groove at both sides smoothly and completely. (Refer to picture 1 & picture 2) . Put the connector of the short sitting surport panel through the hole in the long short sitting surport panel (please refer to the picture 3) . Put the two connectors connected to the connector in the back side panel, please ensure it is fastened fully (please refer to the picture 4) . Place the Bench Surface Panel on the Bench Support Panel and slide toward the Back Wall until flush to the Back Wall. Picture 1 Picture 2 Picture 3/4 Picture 5 Picture 6 IG-570G-1 4 25/10/2007 6. Place the front panel on the floor panel, then lock the two inside latches between front and right side panel and between front and left side panel. .Place the front panel on the floor panel, then lock the two inside latches between front and right side panel and between front and left side panel (Refer to picture 1 ). picture 1 7. Place the top panel on the five side panels. Make sure the connection wires of three side panels(left back, right back )protrudes through the corresponding holes of the top panel. . Make sure the wire is through each hole smoothly and completely. . Make sure the trim of the top panel fits completely around the five side panels. 8. Make sure each of the lead wires on the top of the left back and right back is protruding through the top panel; then plug each of the three lead wires into the three connectors of the top panel. IG-570G-1 5 25/10/2007 9. The power cord has ...