3. When installation of vent pipe is complete, in stall vent termination. Depending on the location of your fireplace, you will vent vertically or horizontally. 4. Allow 1" of pipe to protrude from internal wall, depending on wall thickness. See Figure 7. 5. For horizontal installation, an optional siding standoff may be installed between the vent cap and the exterior wall. Secure horizontal vent cap to standoff. Secure standoff/vent cap assembly to wall (see Figure 7). Do not seal termination to vent pipe. The vent termination must be removable for service pipe inspection. 6. For vertical installation, a vertical termination is available. Also for vertical venting application, install vertical flue restrictor into inner collar of fireplace as shown in Figure 6. When installing a length of pipe for vertical termination that is over 3 ft., support the pipe every 3 ft. using metal wall straps. Vertical to horizontal pipe must be kept at a 1 ft. to 4 ft. ratio with a maximum run of no more than 20 ft. Female Locking Lugs Vertical Flue Restrictor (For Vertical Venting Male Locking Lugs Application) Figure 6 - Venting Installation Figure 7 - Vent Termination (Horizontal) Direct-Vent Pipe CD32M and CD36M-A 4 1/4" Inner and 7 1/4" Outer CD42M-A 5" Inner and 8" Outer Wall Firestop Maintain 1" Minimum Air Space Around Outer Pipe when Penetrating a Wall Horizontal Termination (Vent Cap) Screws Exterior Wall with Vinyl Siding Deflector Shield Minimum Pipe Overlap 1 1/4" Siding Standoff (Optional) Framed Openings CD32M and CD36M-A 10" x 10" CD42M-A 10 3/4" x 10 3/4" VENTING INSTALLATION 1. Install elbow to fireplace collar adapter located on back of the unit at a 45° angle. Slide elbow over collar and twist to lock. Check to insure proper connection (see Figure 6). 2. Continue to install remainder of pipe for desired installation. Make sure each section is twist-locked securely. For more information, visit more information, visit 111916-01A 111916-01A Forr morre iinfforrmattiion,, viisiitt 77 Figure 8 - Vertical Termination with Offset and Wall Strap Wall Strap Roof Flashing 45° Elbows Ceiling Firestop Roof Pitch Minimum Height Above Roof Flat - 7/12 1 ft. (30.48 cm) 7/12 - 8/12 1 1/2 ft. (45.72 cm) 8/12 - 9/12 2 ft (60.96 cm) 9/12 - 10/12 2 1/2 ft (76.20 cm) 10/12 - 11/12 4 ft (121.92 cm) 11/12 - 14/12 5 ft (152.40 cm) 14/12 - 16/12 6 ft (182.88 cm) 16/12 - 18/12 7 ft (213.36 cm) 18/12 - 20/12 7 1/2 ft (228.60 cm) 20/12 - 21/12 8 ft (243.84 cm) INSTALLATION Continued ELECTRICAL HOOKUP AND REMOTE RECEIVER DIAGRAM An outlet box with two receptacles (see Figure 9) has been supplied for your convenience and is located inside on the lower right side of the fireplace. The remote control receiver is factory wired and connected to the convertible gas valve as shown in Figure 10. Figure 9 - Duplex Outlet Three-prong Plug GAS SUPPLY TESTING NOTICE: This section is intended as a guide for qualified technicians installing gas to the appliance. WARNING: Do not connect appliance before pressure testing gas piping. Damage to gas valve may result and an unsafe condition may be created. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). The gas control valve is secured underneath the firebox. Two 1/8" ports are provided on the gas control valve for pressure test gauge connections (see Figure 11). Figure 10 - Remote Control Receiver Figure 11 - Gas Control Valve OFF PILOT ON LO HI PILOT E A 16AI 7 TPTH TP TH ON/OFF Knob Pilot Adjustment Inlet Pressure Outlet Pressure Flame Adjustment Knob Pilot Gas Line Do Not Kink To Pilot Burner To Main Burner Outlet Box OFF TH TP TPTH REMOTEOFFON ON T PILO OT LIP TPTH TP TH Remote Control Receiver Convertible Gas Valve If an offset is necessary in the attic to avoid obstruction, it is important to support the vent pipe every 3 ft. to avoid excessive stress on the elbows and possible separation (see Figure 8, page 7). Clearances must be maintained between the roof and the termination. Refer to chart below. INSTALLATION Venting Installation (Con.) Electrical Gookup and Remote Reeiver Diagram Gas Supply Testing 111916-01A Forr morre iinfforrmattiion,, viisiitt 8 INSTALLATION Continued GAS LINE HOOK-UP WARNING: Gas line hook-up should be done by your gas supplier or a qualified service person. WARNING: Before you proceed, make sure your gas supply is OFF. An equipment shutoff valve has been included in the fireplace's gas supply system. However, consider installing an extra shutoff valve outside the appliance’s enclosure (check local codes), where it can be accesse...
Dieses Handbuch ist für folgende Modelle:Andere Home Zubehör - CD32M (3.3 mb)
Andere Home Zubehör - CD42M-A (3.3 mb)