Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fire- 1 1/2" (38mm) 3" (76mm) Max. 6" (152mm) Max. A B Outer Surround TOP VIEW SAFE ZONE Combustible Material May place opening. Be Used Max. Spacer 3" (76mm) 1 1/2" (38mm) Max. B 6" (152mm) A 12" (229mm) Combustible Materials Header Perpendicular Wall M36E(B,H) M42E(B,H) VM36E(B,H) VM42E(B,H) A 9" (229mm) 6" (152mm) B 12" (305mm) 9" (229mm) Figure 6 - Side Clearances - Top View (Cross Section) M36E(B,H) M42E(B,H) VM36E(B,H) VM42E(B,H) A 14" (356mm) 15" (381mm) B 8" (203mm) 9" (229mm) Figure 5 -Mantel Clearances - Side View (Cross Section) For more information, visit more information, visit 108796-01E 8 8 PRE-INSTALLATION PREPARATION Framing Installing Transition Vent Collar PRE-INSTALLATION PREPARATION Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and secure it. Note:If appliance is to be raised above floor level, a platform must be built to support the appliance. 3. Install the supply line to the appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above the bottom of the appliance. The gas line must be installed through the lower left side access point or alternate access hole in bottom of appliance (see Figure 17, page 11). 4. Repack insulation around gas line to cover any remaining openings in conduit sleeve. Prepare the incoming gas line with teflon tape or pipe joint compound and hook-up incoming gas line to the flexible gas line. Note:If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting. WARNING: When finishing appliance, do not overlap combustible material onto the black front face. Brick, tile, or other noncombustible materials may be applied to the face provided that any gap is between the material used and the face is caulked with a noncombustible caulking. B C A M36E(B,H) M42E(B,H) VM36E(B,H) VM42E(B,H) A 40 3/8" (1020mm) 44 3/8" (1121mm) B 21 3/8" (543mm) 23 1/8" (587mm) C 41 1/4" (1048mm) 48 1/4" (1226mm) Figure 7 - Rough Opening for Installing in Wall A B C D is Permitted M36E(B,H) M42E(B,H) VM36E(B,H) VM42E(B,H) A 24 1/2"(622.3mm) 27 9/16"(700.1mm) B 73 7/8"(1876.4mm) 83 7/8"(2130.4mm) C 52 3/16"(1326mm) 59 5/16"(1506.6mm) D 17 1/4"(438.2mm) 19 1/2"(495.3mm) These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance 3/4" Clearance Not Required at Nailing Flanges Figure 8 - Corner Installation Guidelines INSTALLING TRANSITION PIPE AND STARTER COLLAR The transition pipe and starter collar shown in Figure 9 are supplied with the fireplace, unattached and ready for installation. Remove the starter collar and set aside. Slide the transition pipe over the vent collar and attach with a minimum of three screws. Replace the starter collar over the transition pipe and attach using four screws located on the leg stands (five used on the model M42). To install B-vent piping, slide the first piece of B-vent over the transition pipe and attach with a minimum of two screws. B-Vent Piping Starter Collar Transition Pipe Vent Collar Figure 9 - Installing Transition Pipe and Starter Collar For more information, visit more information, visit 108796-01E VENTING INSTALLATION 9 VENTING INSTALLATION A B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concerning B-type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local building codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code NFPA No. 54/ANSI Z223.1 and in Canada with CAN/CGA B149 for Category I systems using double wall B-1 vent pipe. This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burning appliance. This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chimney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 10 are typical of most B-vent installations and codes practices. Listed Vent Cap Maintain Listed Clearance Support Each Lateral At Least Every Six (6) Feet 6' 8' 60° Position Firestop Maintain Listed Clearance Maintain Listed Clearance 12' Min. Position Firestop Example 1: Shows the minimum allowable system height and lateral offset for a 60° degree or gr...
Dieses Handbuch ist für folgende Modelle:Andere Home Zubehör - M36E(B (3.11 mb)
Andere Home Zubehör - VM36E(B (3.11 mb)
Andere Home Zubehör - VM42E(B (3.11 mb)