Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Atlas, modell Guardian Pro MLGC180W

Hersteller: Atlas
Dateigröße: 146.16 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


(1 m). Sensor Least Sensitive . Loosen the clamp screw in the sensor ball joint and gently rotate the sensor. . Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times whenmotionisdetected).Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (25 mm) away from the bulbs. Most Sensitive Clamp Screw Ball Joint Aim Sensor Down for Short Coverage 4 598-1098-02 SPECIFICATIONS Range ............ Up to 70 ft. (21 m) [varies with surrounding temperature]. Sensing Angle...... Up to 180° Electrical Load. . . . . . Up to 300 Watt Maximum In candescent [Up to 150 Watt maximum each bulb holder.] Power Requirements . 120 VAC, 60 Hz Replacement Lamp . . Upto150WattMaximumPAR38 Incandescent or Halogen (Not CFL) Bulbs. Operating Modes. . . . TEST, AUTO and MANUAL MODE Time Delay ........1, 5, 10 minutes Atlas Lighting Products, Inc. reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold. TROUBLESHOOTING GUIDE If you experience a problem with your Light Control, first follow this guide. For additional assistance write to: Atlas Lighting Products, Inc. • Customer Service Department • P.O. Box 2348 • Burlington, NC 27216 SYMPTOM POSSIBLE CAUSE SOLUTION Lights will not come on. 1. Light switch is turned off. 2. Flood lamp is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is in effect. 5. Incorrect circuit wiring, if this is a new installation. 6. Light control aimed in wrong direction. 1. Light control may be installed in a relatively dark location. 2. Light control is in TEST. 1. Light control may be sensing small animals or automobile traffic. 2. Range is set too high. Light control may be installed in a relatively dark location. 1. A flood lamp is positioned too close to the light control or pointed at nearby objects that cause heat to trigger the light control. 2. The light control may be picking up a heat source like an air vent, dryer vent, or brightly painted, heat- reflective surface. 3. Light control is in manual mode. 1. Heat or light from the flood lamps may be turning the light control on and off. 2. Heat being reflected from other objects may be turning the light control on and off. 3. Light control is in the TEST mode and warming up. 4. Light may be leaking through the flood lamp reflectors. Light control is detecting its own lights. 1. Turn light switch on. 2. Check flood lamp and replace if burned out. 3. Replace fuse or turn circuit breaker on. 4. Recheck after dark. 5. Verify wiring is correct. 6. Re-aim light control to cover desired area. 1. The fixture is operating normally under these conditions. 2. Set control switch to 1, 5, or 10 minutes. 1. Re-aim light control. 2. Reduce range. Relocate light control. 1. Reposition the flood lamp away from the light control or nearby objects. 2. Reduce range. 3. Switch light control to AUTO. 1. Reposition the flood lamp away from the light control. 2. Reposition light control. 3. Flashing is normal under these conditions. 4. Replace the flood lamps with new high quality PAR 38 lamps. (Make sure the metal lamp protectors are installed). Reposition flood lamps to keep area below the light control relatively dark. Lights come on in daylight. Lights come on for no apparent reason. Lights turn off too late in Dusk-to-Dawn setting. Lights stay on continuously. Lights flash on and off. Lights flash once, then stay off in manual mode. 598-1098-02 5 FIVE YEAR LIMITED WARRANTY Atlas Lighting Products, Inc. warrants against defects in materials or workmanship for a period of five years from the date of purchase for use, and agrees to repair or, at our option, replace a defective unit without charge for either parts or labor. IMPORTANT: This warranty does not cover damage resulting from accident, misuse of abuse, lack of reasonable care, the affixing of any attachment not provided with product, alteration of any attachments factory installed, loss of parts or subjecting the fixture to any but the specified electrical service. This warranty does not cover failure of the bulb due to accidents, abuse, misuse, vandalism, power surges, and acts of nature such as lightning damage. No responsibility is assumed for any special incidental or consequential damages.Damages occurring during transit are not covered by this warranty-including UPS shipments.To obtain warranty service, mail sales receipt as proof-of-purchase, date and a brief explanation of the nature of the defect, to the address listed below.You will receive, by mail, a Return Goods Authorization number and full instructions for returning defective merchandise.All returned goods must be accompanied by a Return Goods Authorization number issued by Atlas Lighting Products, Inc. NOTE:No other warranty, written or verbal, is authorized by Atlas Lighting Products, I...

Dieses Handbuch ist für folgende Modelle:
Andere Home Zubehör - Guardian Pro MLGC180B (146.16 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien