To avoid damage to the spa, do not activate power to the spa until these modifications have been made. We recommend Square-D or Cutler Hammer circuit breakers. important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid damage to the spa, do not activate power to the spa until these modifications have been made. We recommend Square-D or Cutler Hammer circuit breakers. This section describes the power configuration choices (Standard 60 Amp or Alternate 50 Amp) for Maxxus hot tub models. Note Wire size must meet NEC recommendations and is determined by maximum current draw and length or run. Config. #1Standard 60A Configuration (factory setting) 240 VAC/60A 3-wire configuration • (2 hots and ground) 60A dual-pole GFCI breaker (hard • wired only) Maximum electrical current draw• of 48A In the Standard 60A configuration, the heater operates while any two jets pumps and the blower are running. However, the heater does not operate when all three jets pumps are running. Config. #2 Alternate 50A Configuration 240 VAC/50A 3-wire configuration • (2 hots and ground) 50A dual-pole GFCI breaker (hard • wired only) Maximum electrical current draw• of 38A If your home does not have 240 VAC/60A power available, connect the spa to a 240 VAC/50A power source. Then, have a qualified electrician modify the circuit board to match the power source. In this configuration, the heater yields the same rapid temperature rise as in the 60A configuration. However, the heater does not operate while any two jets pumps are running. important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid damage to the spa, do not activate power to the spa until these modifications have been made. We recommend Square-D or Cutler Hammer circuit breakers. important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid damage to the spa, do not activate power to the spa until these modifications have been made. We recommend Square-D or Cutler Hammer circuit breakers. This section describes the power configuration choices (Standard 50 Amp, Alternate 40 Amp, or Alternate 60 Amp) for Altamar, Cameo, Majesta, Marin, and Optima hot tub models. Note Wire size must meet NEC recommendations and is determined by maximum current draw and length or run. Config. # 1Standard 50A Configuration (factory setting) 240 VAC/50A 3-wire configuration • (2 hots and ground) 50A dual-pole GFCI breaker • (hard wired only) Maximum electrical current draw• of 40A In this Standard 50A configuration, the heater does not operate while both jets pumps are running. Config. #2 Alternate 40A Configuration (For homes where 240 VAC/50A or 240 VAC/60A power is unavailable). 240 VAC/40A 3-wire configuration • (2 hots and ground) 40A dual-pole GFCI breaker • (hard wired only) Maximum electrical current draw• of 26A If your home electrical service does not have 240V/50A power available, the spa may be connected to a 240V/40A power source after a qualified electrician makes a minor circuit board modification. In this configuration, the heater yields the same rapid temperature rise as in the 50A configuration, but does not operate while either jets pump are running or when the blower is running. Config. #3Alternate 60A Configuration 240 VAC/60A 3-wire configuration • (2 hots and ground) 60A dual-pole GFCI breaker • (hard wired only) Maximum electrical current draw• of 48A In the Alternate 60A configuration, the heater operates while both jets pumps and the blower are running. important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid damage to the spa, do not activate power to the spa until these modifications have been made. We recommend Square-D or Cutler Hammer circuit breakers. important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid damage to the spa, do not activate power to the spa until these modifications have been made. We recommend Square-D or Cutler Hammer circuit breakers. This section describes the power configuration choices (Standard 50 Amp, and Alternate 40 AMP) for Capri hot tub models. Note Wire size must meet NEC recommendations and is determined by maximum current draw and length or run. Config. # 1Standard 50A Configuration (factory setting) 240 VAC/50A • 3-wire configuration (2 hots and a ground) 50A dual-pole GFCI breaker (hard • wired only) Maximum electrical current draw• of 40A In this Standard 50A configuration, the heater does run if the jets pump and blower are running. Config. #2 Alternate 40A Configuration (For homes where 240 VAC/50A is unavailable). 240 VAC/40A 3-wire configuration • (2 hots and a ground) 40A dual-pole GFCI breaker (hard • wi...
Dieses Handbuch ist für folgende Modelle:Andere Home Zubehör - Spas 780 Series (1.5 mb)
Andere Home Zubehör - Spas 880 Series (1.5 mb)