Water temperature is displayed. Water temperature in the spa has reached 112.F (44.C). Do not enter the water! Allow water to cool down. The system will reset au- tomatically when water reaches 109.F (43.C). Call your dealer or service supplier if problem persists. 3 flashing dots are dis- played. A problem has been de- tected. Do not enter the water! Check and open water valves. Clean filters if nec- essary. Check water level. Add water if needed. Shut power off and power your spa up again to reset the system. Call your dealer or service supplier if problem persists. The display is flashing. A power failure has occurred. Press any key to reset the system, then reprogram all desired parameters. Press and hold Light key for 5 seconds to display water temperature in either Fahrenheit (.F) or Celsius (.C). Temperature display unit: The display toggles every 5 seconds alternately showing the hourly time and the current water temperature. Time & temperature display: Turning the light on: The Quick Reference Card provides a quick overview of your spa's main ons and the operations accessible with your digital control pad. •MC-MP-DY4SpaPack• Pressing Light key once turns light on at high intensity. Pressing a second time turns light to low intensity. A third time turns light off. A built-in timer turns light off after 2 hours, unless it has been manually deactivated. The "Light" icon is displayed when light is on at high intensity. It flashes when light is on at low intensity. Fiber Box Option: If spa has an optional fiber box only, pressing Light key turns fiber box (motor & light) on. Pressing again turns fiber box motor off but leaves light on. A third time turns both motor and light off. A built-in timer turns fiber box off after 2 hours, unless it has been manually deactivated. The "Light" icon is displayed when fiber box light is on. It flashes when fiber box motor and light are on at the same time. LED Light Option: If spa has an optional LED light, Press Light key to turn LED lights on. To advance to the next color/display setting, press Light key twice. The LEDs will go off with the first press, then back on in the next setting with the second press. If the LEDs remain off for more than 5 sec., the color/ display sequence will reset and start back at the beginning the next time the Light key is pressed. Color/ display sequences are: 1• LEDs light up and slowly cycle through all six colors. The slow cycle restarts at the beginning and repeats. 2• LEDs light up and remain on in Aqua. 3• LEDs light up and remain on in Purple. 4• LEDs light up and remain on in Blue. 5• LEDs light up and remain on in Gold. 6• LEDs light up and remain on in Green. 7• LEDs light up and remain on in Red. 8• LEDs light up for 2 sec., flash off, then flash on in the next color until all six colors have been displayed. The flashing cycle then repeats itself. 9• LEDs flash on/off quickly for a strobe light effect. A built-in timer turns lights off after 2 hours unless manually deactivated first. The "Light" icon is displayed when light is on. The filter cycle is suspended if the water temperature raises more than 2.F (1.C) above Set Point or if a pump has been started manually. The "Filter" icon will blink (on 0.5 second, off 0.5 second, on 0.5 second, off 1.5 seconds). functi Starting Pump 1: Press Pump 1 to turn Pump 1 on at low speed. Pressing a second time turns Pump 1 to high speed. A third time turns Pump 1 off. When at high speed, a built-in timer turns pump off after 20 minutes and when at low speed after 2 hours, unless it has been manually deactivated. The "Pump 1" icon lights up when Pump 1 is on at high speed. It flashes when Pump 1 is on at low speed. Starting Pump 2: Press Pump 2 once to turn Pump 2 on at low speed. Pressing a second time turns Pump 2 to high speed. A third time turns pump off. A built-in timer turns pump off after 20 minutes, unless manually deactivated first. The "Pump 2" icon lights up when Pump 2 is on at high speed. It flashes when Pump 2 is on at low speed. Starting the blower: Press Blower to turn blower on at high speed. Press a second time to turn blower to low speed. A third time turns blower off. A built-in timer turns blower off after 20 minutes, unless manually deactivated first. The "Blower" icon lights up when blower is on at high speed. It flashes when blower is on at low speed. Automatic water heater start: When water temperature is 1.F (0.5.C) lower than the Set Point, the heater will automatically turn on until water temperature reaches Set Point plus 1.F (0.5.C). The "Heater" icon lights up when the heater is on. It flashes when there is a request for more heat but the heater has not yet started. Setting water temperature: Use Up or Down arrow key to regulate water temperature. The temperature setting will be displayed for 5 seconds to confirm your new selection. The "Set Point" symbol indicates the desired temperature, NOT the current water temperature! Water temperature can be adjus...