Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Athena Technologies, modell A88028

Hersteller: Athena Technologies
Dateigröße: 801.08 kb
Dateiname: d74cb22a-a15a-431f-95f4-3d197ee5bc4b.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


32 170 19 y Product Code No. A88028 The Data Badge and Serial Number are located on the left hand side of the back panel. PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER 1 SERVICE AND INSTALLATION CONTENTS LAYOUT INTRODUCTION AND GENERAL INSTALLATION REQUIREMENTS 1.0 TECHNICAL DATA 2.0 CONDITIONS OF INSTALLATION 2.1 SITING GENERAL 2.2 FLUES AND CHIMNEYS 2.2.1 Brick Chimney, 178mm diameter (7 inch) Stone or Lined Flue and 125mm diameter (5 inch) Flue 2.2.2 Pre-Cast Flue 2.2.3 Metal Fluebox 125mm diameter (5 inch) Flues 2.3 SHELF HEIGHT AND SIDE CLEARANCES 2.3.1 Combustible Shelf 2.3.2 Non-Combustible Shelf 3.0 INSTALLATION OF FIRE 3.1 UNPACKING 3.2 PREPARATION OF FIRE 3.2.1 Spigot Restrictor 3.3 METHODS OF INSTALLATION 3.3.1 Fixing by Tension Cable 3.3.2 Fixing Directly onto Wall 3.4 GAS CONNECTION 3.4.1 Concealed Connection 3.4.2 Front Connection 3.5 TEST FOR GAS SOUNDNESS 4.0 COMMISSIONING 4.1 INSTALL FUEL EFFECT COMPONENTS 4.2 CHECK GAS PRESSURE 4.3 FIT TRIM AND FENDER 4.4 TEST FOR SPILLAGE 4.5 CHECK IGNITION 4.6 CHECK OPERATION OF FSD 5.0 INSTRUCT USER 6.0 SERVICING INSTRUCTIONS 6.1 REMOVE BURNER TRAY 6.2 MAIN BURNER INJECTOR 6.3 GAS TAP ASSEMBLY 6.4 PILOT ASSEMBLY 6.5 FUEL EFFECT COMPONENTS 6.6 MAIN BURNER 6.7 CONTROL KNOB 6.8 IGNITION UNIT 6.9 IGNITION BATTERY 6.10 IGNITION MICRO SWITCH 6.11 THERMOCOUPLE BREAK MICRO SWITCH 7.0 HINTS ON FAULT FINDING 8.0 SHORT LIST OF PARTS 2 INTRODUCTION NO COMPONENT OF THIS FIRE IS MANUFACTURED FROM ASBESTOS OR ASBESTOS RELATED PRODUCTS. The ATHENA L.F. is an open fronted inset live coal effect gas fire specially designed for Pre-Cast Flue application and is also suitable for use with Brick Chimneys, twin walled or insulated Metal/Pre-fabricated Flues of 125mm minimum diameter and Flueboxes conforming to the constructional requirements of BS 715. It is fitted with a combined flame supervision and oxygen depletion monitoring device. The fire is for hearth mounting only on a non-combustible hearth. The fire is for use on Natural Gas only. GENERAL INSTALLATION REQUIREMENTS In your own interest and that of safety, it is the law that all gas appliances are installed by competent persons in accordance with the current Gas Safety (Installation and Use) Regulations. Failure to install appliances correctly could lead to prosecution. The installation MUST be in accordance with these installation instructions, all the relevant parts of the Local and National Building Regulations or Building Standards (Scotland) (Consolidation) Regulations and the relevant recommendations of the current editions of the following British Standards: B.S. 5871 : Part 2 B.S. 5440 : Parts 1 & 2 B.S. 6891 B.S. 6461 : Parts 1 & 2 B.S. 715 B.S. 1251 B.S. 1289 : 1975 B.S. 1289 : Part 1 : 1986 B.S. 1289 : Part 2 : 1989 Any other relevant British Standard Code of Practice and/or Local Building Regulations and in accordance with the rules in force. 1.0 TECHNICAL DATA 1.1 DIMENSIONS (Overall) mm Height 682 Width 635 Depth 115 Forward Projection 100 Height to top of flue aperture 529 Weight 18 Kg 1.2 INPUTS AND PRESSURES Maximum Heat Input (Gross) 6.0 kW 20470 Btu/h Minimum Heat Input (Gross) 2.3 kW 7848 Btu/h Supply Pressure 20.0 mbar Setting Pressure Cold 13.0 mbar ± 1mbar Gas Rate Adjustment NONE 1.3 BURNER AND CONTROL DETAILS Main Burner y 992174 Pilot Burner SIT OP 9063 Injector (Main Burner) Bray Cat 82/440 Ignition Battery Operated Electronic Ignition. Battery Size 9V MN1604 or 6LR61 Control Tap Concentric (with FSD) Model Number TESA 2762-025 Spark Gap 3.0mm to 5.0mm Control Knob Settings OFF, HIGH, MED, ECON, PILOT 3 2.0 CONDITIONS OF INSTALLATION 2.1 SITING GENERAL This fire is suitable for hearth mounting only on a non-combustible hearth at least 13mm thick and measuring at least 630mm wide by 330mm deep. Its top surface should preferably be 50mm above the floor level in order to discourage the placing of carpets or rugs over it. It MUST NOT be fitted directly on a combustible wall. The fire should be installed so that no part of a combustible wall o i.e. not part of the fire surround but a full wall at 90 to the fire is less than 500mm from the radiant source. If this is not possible the combustible side wall must be suitably protected. FIREPLACE OPENING The front opening of the fireplace must be between 305mm and 457mm wide and between 560mm and 585mm high (see Section 2.2). If the opening is greater it must be bricked up until the opening is a maximum of 585mm high and 457mm wide, alternatively a non-combustible infill panel may be used to achieve the required dimensions. DO NOT USE THE BACK OF A FIRE SURROUND OR MARBLE TO ACHIEVE THE ABOVE DIMENSIONS. There must be a minimum flat surface area around the fireplace opening shown by the dotted lines in fig. 1 to ensure a good seal between the fireplace and the fire. This area should be sound enough to take the wall plugs and screws supplied for front fixing. Ensure that the base of the fireplace is level with the hearth and reasonably flat to prevent...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien