Anleitung Zusammenfassung


(2-3/4) 165mm (6-1/2) 279mm (11") 229 X 305mm (9" X 12") CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 2159mm (85") 1080 mm (42-1/2") C/L 1524mm (60") 1076mm (42-3/8") 1080mm (42-1/2") PUMP C/L OF DRAIN OUTLET PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS ELLISSE (MODEL 2711L) 1829mm (72") 927mm (36-1/2") OUTLINE OF CUTOUT 1791 X 1181 (70-1/2" X 46-1/2") C/L OF DRAIN 102mm (4") PUMP 305mm (12") 1219mm (48") 229mm x 356mm (9" x 14") FLOOR CUTOUT RECOMMENDED FITTING LOCATION 64 X 279mm (2-1/2" X 11") OPTIONAL DECK FITTING AREA PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS 229 x 305mm (9 X 12) FLOOR CUTOUT 64mm REF. (2-1/2) 1676mm (66") PUMP 914mm (36") 457mm (18) 330mm (13") INTEGRAL FITTING DECK 152mm (6) OUTLINE OF CUTOUT C/L OF DRAIN OUTLET PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7. 753737-100 Rev. E 8 ROUGHING-IN REFERENCES CADET 6' x 42" (MODEL 2774L) RECOMMENDED FITTING LOCATION 64 X 330mm (2-1/2" x 13") FOR PIER OR ISLAND INSTALLATIONS ONLY ALT. FITTING LOCATION #1 1829mm (72") 1067mm (42") 533mm (21") 229mm (9") 305mm (12") 57mm (2-1/4") (8) JETS CUTOUT IN FLOOR FOR DRAIN PUMP FINISHED WALL 19mm (3/4") 229mm (9") (2) AIR VALVES OUTLINE OF CUTOUT 1791mm x 1029mm (70-1/2" X 40-1/2") C/L OF DRAIN DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7. CADET 6' x 36" (MODEL 2773L) RECOMMENDED FITTING LOCATION 64 X 330mm (2-1/2" x 13") FOR PIER OR ISLAND INSTALLATIONS ONLY ALT. FITTING LOCATION #1 1829mm (72") 908mm (35-3/4") OUTLINE OF CUTOUT 1791mm x 870mm (70-1/2" X 34-1/4") 454mm (17-7/8") 229mm (9") 305mm (12") 57mm (2-1/4") (8) JETS CUTOUT IN FLOOR FOR DRAIN PUMP FINISHED WALL 19mm (3/4") 229mm (9") C/L OF DRAIN (2) AIR VALVES 5' x 32" (MODEL 2732L) 60" (1524mm) PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 32-3/4" (832mm) 5-7/8" (149mm) 12" (305mm) 6" (152mm) 3" (76mm) 8-1/2" (216mm) 16-1/2" (419mm) CUT OUT IN FLOOR FOR DRAIN PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 9 753737-100 Rev. E INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access opening. 1. Position the whirlpool into the installation opening and level the deck in both directions, shimming the integral support feet IF necessary. Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1). 2. Remove the whirlpool and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line. ! The rim of the bath must not support weight. FIGURE 1 3. Install drain components to the whirlpool following the drain installation instructions. Before replacing your whirlpool for final installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing and Table 1 for suggested opening size (shadowed) and location dimensions. The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a cutout in the floor. ! The floor structure beneath the bath must be able to support a total weight of bath, water, and bather. Refer to Table 1 under total weight for your model. For Models: 2425L/V-LHO and 2425L/V-RHO, 2732L; This bath must be supported along its entire bottom. Use mortar as bedding material (do not use sand or foam). Apply enough mortar to support the complete bottom of the bath. After the mortar has been poured, and before it sets, position whirlpool or bath within recess until the rim is leveled against the leveling stringers (see "Typical Recess Installation") shown below. C TYPICAL INSTALLATION ! The rim of the bath must not support weight. Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath. Any finish material such as tile or wall board must be self-supporting if it contacts the deck of the bath. For Models: 2645L/V, 2771L/V, 2773L/V, 2774L/V, 2775L/V, 2422L/V, 2711L/V, 2908L/V, 6060L/V and 7236L/V; Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base consisting of cement, mortar, or grout will help provide a solid and secure installation. ! The rim of the bath must not support weight. If foundation base is used, a...

Dieses Handbuch ist für folgende Modelle:
Andere Home Zubehör - 2645L / V (1.75 mb)
Andere Home Zubehör - 2422L / V (1.75 mb)
Andere Home Zubehör - 2732L (1.75 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien