Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung American Standard, modell 2703.XXXW Series

Hersteller: American Standard
Dateigröße: 71.34 kb
Dateiname: dc92241e-a0e5-4323-8ef2-29076f7255f6.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks. If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system. Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations). Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth. WARNING! Do not lift whirlpool by the piping harness at any time. FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS. © American Standard Inc. 2003 752352-100 REV. H All product names listed herein are trademarks of American Standard Inc. unless otherwise noted. FRAMING AND INSTALLATION BATH MAY ONLY BE INSTALLED ABOVE THE FLOOR LINE IN A RECESS TYPE INSTALLATION, AS SHOWN IN RECESS INSTALLATION DIAGRAM. THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED. THE SUMP OF THE BATH IS SUPPORTED BY INTEGRAL FEET AND NO ADDITIONAL SUMP SUPPORT IS REQUIRED. ONCE THE BATH IS IN PLACE, THE FEET SHOULD BE SHIMMED ACCORDINGLY, SO THAT THE RIM OF THE BATH CONTACTS THE STRINGER OR PIER BUT SUPPORTS NO WEIGHT. ANY FINISH MATERIAL, SUCH AS TILE OR WALL BOARD, MUST BE SELF-SUPPORTING IF IT CONTACTS THE RIM OF THE BATH. LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR REAR MOTOR MOUNT WHIRLPOOLS, PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS. BATH FLANGE DRYWALL SCREW STUD FLANGE BRACKET STUDBATH TYPICAL RECESS INSTALLATION STUD FLANGE BRACKET INSTALLATION 610mm (24) 305mm (12) 1527mm (60-1/8) 533mm (21) 775mm(30)813mm(32)TUB WIDTH 1 X 3 X 8 LEVELING STRINGER 1 X 3 LEVELING STRINGER 2 X 4 STRINGER SUPPORT WHIRLPOOL ONLY: UNLESS AN ACCESS OPENING OF AT LEAST 305mm X 610mm(12" X 24") IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED. SECURE THE BATH TO THE STUDS AS SHOWN USING THE SCREWS AND BRACKETS PROVIDED - SEE STUD FLANGE BRACKET INSTALLATION TILE WALL BOARD LEVELING STRINGER BATH ADHESIVE SEALANT STUD FLANGE BRACKET INSTALLATION PROVIDED WITH THE BATH IS A PACKAGE OF (4) FOUR STUD FLANGE BRACKETS AND (8) EIGHT SCREWS. INSTALL BRACKETS AND SCREWS AS SHOWN IN WALL BRACKET INSTALLATION DETAIL. TWO BRACKETS SHOULD BE LOCATED EVENLY ACROSS THE BACK TILE FLANGE AND INSTALL ONE BRACKET ON EACH END OF THE BATH, TOWARDS THE FRONT END OF THE TILE FLANGE. THIS WILL ALLOW TILE FLANGE TO BE HELD SECURELY AGAINST STUDWALL OF RECESS INSTALLATION. 752352-100 REV. H (2) SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Grounding is required. The unit should be installed by a licensed electrician and grounded. 3. Install to permit access for servicing. 4. All building materials and wiring should be routed away from the pump body and heater (if equipped). 1.6 HORSEPOWER MODELS: The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT. 2.1 HORSEPOWER MODELS: The whirlpool should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit fron the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT. ELECTRICAL DIAGRAM READ AND FO...

Dieses Handbuch ist für folgende Modelle:
Andere Home Zubehör - 2705.XXXW Series (71.34 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien