Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Axor, modell 15100XX1

Hersteller: Axor
Dateigröße: 471.1 kb
Dateiname: argh0393.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


flow rate Automatic turnoff 14.5 – 116 psi 120oF – 140oF* 2.2 gpm after 35 sec. Battery Hole size Max. countertop depth Lithium CR-P2/6V 1 3/16” 1 3/4” Installation Considerations • This unit cannot be used with a continuous flow water heater. • Large differences in pressure between the hot and cold water supplies should be balanced. • Do not twist or kink the supply hoses • Flush the supply lines thoroughly before installing this faucet. Debris can clog the filter screens and aerator, causing unsatisfactory flow from the faucet. Debris problems are not covered under the Hansgrohe warranty. • The check valves and the filter screens should be checked periodically. • This faucet does not include a drain. 3 Installation Instructions • Remove the mounting nut, metal washer, and fiber washer from the faucet. • Place the faucet with sealing gasket on top of the sink.(1) • From beneath the sink, install the fiber washer, metal washer, and mounting nut (2). • Install the adapters to the hot and cold stops (3). Attach the check valves and filter screens to the adapters (4). Attach the hoses to the check valves (5) using two wrenches, as shown. Take care not to twist or kink the supply hoses. Model 15100XX1 • Turn on the water supplies (1). Remove the protective cover from the sensor (2). Wait 15 seconds (3). • Place your hand in front of the sensor to turn the water on (4). • Adjust the temperature of the water with the lever on the side of the faucet. Pivot it forward to obtain cooler water, backward to obtain warmer water. 4 Model 15101XX1 • Turn on the water supplies (1). Remove the protective cover from the sensor (2). Wait 15 seconds (3). • Place your hand in front of the sensor to turn the water on (4). Check the temperature of the water. • If adjustment of the temperature is necessary, turn the water off at the supplies (1). Remove the set screw from the rear of the faucet using a 2.5 mm allen wrench (2). • Pull the faucet housing off (1). • Use a slot-head screwdriver to adjust the temperature control screw (2). Turn it clockwise to make the water warmer, counter-clockwise to make the water cooler. • Re-assemble the faucet and turn the water on. Test again. Repeat the process if necessary until the desired temperature is reached. Clean the Sink • Cover the sensor for 5 seconds (1). The faucet will be shut off for approximately 75 seconds to permit cleaning (2). 5 Change the Battery • Turn the water off at the supplies. • Both models: Remove the set screw from the rear of the faucet with a 2.5 mm allen wrench (1). • Model 15100 only: Remove the temperature control handle (2) • Pull the faucet housing off • Pull the out battery out and put the new one in (3, 4). • Reassemble the faucet and test. If the flow is unsatisfactory: Clean the aerator • Cover the sensor for 5 seconds (1). • Remove the aerator (2). • Flush the aerator thoroughly and reinstall. Clean the filter screens • -Turn the water supplies off. Disconnect the supply hoses. • Remove and clean the filter screens (2). • Reinstall the filter screens. Reconnect the hoses. • Turn the supplies on. Replacement Parts 1 aerator 96788XXX 2 solenoid valve 96904000 3 fixation set 97812000 4 connection hose 96405001 5 adapter 6 electronics 96905000 7 battery Lithium CR-P2/6V or equivalent 8 check valve 5 3 1 2 4 6 7 8 Cleaning Recommendation for Hansgrohe Products Modern faucetry and shower products utilize a combination of materials to comply with the needs of the market with regard to design and functionality. To avoid damage, it is necessary to use some caution when cleaning. Damage caused by improper treatment is not covered under the Hansgrohe warranty. Cleaning Materials for Faucets and Showers • To remove lime scale, use only products made specifically for that purpose. Always follow the manufacturer’s instructions when using. • Do not use cleaners that contain hydrochloric, formic, acetic, or phosphoric acids, as these will cause considerable damage to finishes and to plastic components. • Never mix cleaning materials. • Never use cleaners containing abrasives. Do not use abrasive cleaning cloths, pads, or sponges. Cleaning Procedures • Clean your faucets and shower products as and when required. Regular cleaning will prevent scale buildup and water spotting. • Follow the label instructions. Do not allow any cleaner to remain on the product for longer than necessary. • When using spray cleaners, spray first onto a sponge or cloth – do not spray directly onto the product. • After cleaning, rinse thoroughly with clear water to remove any cleaner residue. Important • Soap and shampoo residue can also cause damage to the product. Rinse well with clean water after use. • If the surface is already damaged, harsh cleaning materials will cause further damage. Limited Lifetime Consumer Warranty This product has been manufactured and tested to the highest quality standards by Ha...

Dieses Handbuch ist für folgende Modelle:
Andere Home Zubehör - 15101XX1 (471.1 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien