Anleitung Raypak, modell Hot Water Storage Tank ASME CODE

Hersteller: Raypak
Dateigröße: 551.94 kb
Dateiname: 0752a786-4ef8-40af-92b8-2a2b69ef2756.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Installed individually or as several tanks in parallel, this tank can provide 80% draw without an appreciable temperature decrease in single temperature application. FEATURES 175 - Gallon storage ASME constructed 150 PSI maximum working pressure Two magnesium anodes Meets ASHRAE 90.1 Los Angeles city approval application no. M-880057 Insulated and jacketed R-16 value insulation Foam insulation Handhole Fits through 36” doorway Labels for each opening Large 1" drain port Approx. Shipping Weight: 596 lbs. Steel Jacket - Complete unit is enclosed in baked enamel steel jacket. With minimum care, the jacket will remain attractive and colorful for years. Tank Openings - Circulating tank connections and hot water outlets are 2-1/2” NPT. Other openings are for T and P valve, tankstat, thermometer and drain port. (Drain valve not provided.) Handhole - Equipped with 3" x 4-1/8" handhole for easy cleanout and inspection. Labels - Openings are individually labeled for easy identification. SAMPLE SPECIFICATION The hot water storage tank shall be a Raypak 175-gallon factory insulated and jacketed tank. The tank shall have a double coating of a high temperature glass lining and be equipped with two (2) magnesium anode rods. The tank shall be ASME constructed and designed for 150 PSI working pressure and equipped with a handhole for cleaning and inspection. The tank shall be insulated with rigid polyurethane foam that completely surrounds the tank and shall be enclosed in a baked enamel steel jacket. The tank insulation must be R-16 value and must meet or exceed ASH RAE standard 90.1. The tank shall be covered by a five (5) year limited warranty against corrosion. CONSTRUCTION CODE • Storage Tank - The tank is lined with a double coating of a high-temperature glass formula. It is built for long life under any water conditions. Two magnesium anode rods are factory installed. • R-Foam Insulation - Rigid polyurethane foam insulation for improved economy and fuel savings. The insulation is R-16 value and complies to ASHRAE 90.1. A Rheem® Company Catalog No.: 4000.21 K Effective: 03-15-08 Replaces: 12-28-07 ASME CODE TANK (175 GALLONS) HEATER MOUNTED PRESSURE OPTIONAL INTEGRAL PUMP (MODELS: 514 thru 1826) RECIRCULATION = KEY = ¥ & PRESSURE RELIEF VALVE PUMP jr UNION * GATE VALVE CHECK VALVE jP BALL VALVE THERMOMETER PUMP LOCATION ON MODELS: 181-401 à 2100-4001 OR ON MODELS 514-1826 WITHOUT INTEGRAL PUMP ''RECIRCULATION PUMP (BY OTHERS) NOTES: 1. PLUMB SWING CHECK VALVE IN GRAVITY CLOSED POSITION. /2\ PIPE ALL RELIEF VALVES TO DRAIN, OR AS LOCAL CODES REQUIRE. 3. LOCATE TEE AS CLOSE AS POSSIBLE TO TANK. INSTALL COLD WATER BETWEEN HEATER OUTLET AND TANK. 5. SEE CHART "MINIMUM PIPE SIZES" FOR MINIMUM PIPE SIZES. 6. SIZING BASED ON HEATER AND TANK BEING PLACED FIVE FEET APART, IF DISTANCE IS GREATER, THE PUMP MUST BE SIZED TO ACCOMMODATE INCREASE IN PIPING RELATED LOSSES. I7\ PROVIDE FOR THERMAL EXPANSION OF HOT WATER IF A BACKFLOW PREVENTER, CHECK VALVE, WATER METER OR PRESSURE- REDUCING VALVE IS INSTALLED IN THE COLD WATER LINE. MINIMUM PIPE SIZES MAIN 133 1-1/2” 181-401 2” 514-824 2-1/2" 926-1825 3” 210Q-4QG1 4” GUARANTEED 80% DRAW WITHOUT TEMPERATURE DROP, USE RAYPAK HEATER, TANK, SIZING TABLE AND HOOK-UP DATA PIPING: UNI-TEMP 80, 1 HEATER, 1 VERTICAL TANK, 1 TEMP DRAWING 8054 REV 8 SPECIFICATIONS 1” NPT RELIEF VALVE ’’THERMOMETER” LABEL ’’RELIEF VALVE” LABEL 2-1/2” NPT OUTLET MAGNESIUM ANODE (7/8” X 58”) (2 PLC’S) 8” DIA 3/4” NPT THERMOMETER Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725 Litho in U.S.A....


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien