Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Desa, modell ODGR400

Hersteller: Desa
Dateigröße: 1.38 mb
Dateiname: c5f8374f-5ff1-4140-bd0d-e758f23cd2b1.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


cm/kg) of stored fuel capacity and not less than a total free area of 10 square inches (64.5 sq. cm). If ventilation openings at floor level are in a side all, there shall be at least two openings. The bottom of the openings shall be at floor level and the upper edge no more than 5 inches (127 mm) above the floor. The openings shall be equally sized, spaced at 180 degrees (3.14 rad) and unobstructed. 3. Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2 mm) diameter rod. Cylinder valves shall be readily accessible for hand operation. A door on the enclosure to gain access to the cylinder valves is acceptable, provided it is non-locking and can be opened without the use of tools. There shall be a minimum clearance of 2 inches (51 mm) between the lower surface of the floor of the LP-gas supply cylinder enclosure and the ground. The design of the appliance shall be such that (1) the LP-gas supply cylinder(s) can be connected, disconnected and the connections inspected and tested outside the cylinder enclosure; and (2) those connections which could be disturbed when installing the cylinder(s) in the enclosure can be leak tested inside the enclosure. Description The ODGR Series are radiant fireplaces. Do not burn wood or other materials in these appliances. Each model is available with standing pilot for use with Natural or Propane gas units. Report to your dealer any parts damaged in shipment. Adequate combustion and ventilation air must be provided. The flow of combustion and ventilation air MUST NOT be obstructed. Provide adequate clearances around the air opening into the combustion chamber; and adequate accessibility clearance for servicing and proper operation. NEVER obstruct the front opening of the appliance. This fireplace is not designed to be water tight. Therefore, when installing this unit against an exterior wall, the wall must be finished before setting unit in place. Fireplace Dimensions 36" (914mm) 40" (1016mm) 39......" (1007mm) ......" (16mm) ......" (13mm) ......" .........." (822mm) ...." (622mm) 43......" (1111mm) 8......" (210mm) ........" (165mm) ........" (191mm) Gas Line AccessRough Opening Height ......" (16mm) 22" (559mm) .........." (572mm) ...." (559mm) RecessedNailingFlangeRough Opening Width 41" Rough Opening Depth3......" (95mm) (1041mm) 3......" (98mm) 7114ODUVSR36ASpecs11/0368......" (1740mm) 48......" (1232mm) 48......" (1232mm) 14......" (362mm) 3......" (95mm) Low VoltageWire Access14......" (362mm) Low Voltage WireAccess Fig. 1 ODGR400 specification and framing dimensions. Fireplace Dimensions 42" (1067mm) 46" (1168mm) 39......" (1007mm) ......" (16mm) 50" (1270mm) 50" (1270mm) ......" (13mm) ......".......... " (1791mm) ...." (610mm) 43......" (1111mm) ........" (191mm) ........" (165mm) ........" (191mm) Rough Opening Height ......" (16mm) 22" (559mm) .........." (572mm) .........." (667mm) RecessedNailingFlangeRough Opening Width 47" Rough Opening Depth3" (76mm) 35......" (895mm) (1194mm) 7114ODUVSR42Aspecs11/0314......" (362mm) 3......" (95mm) Low VoltageWire AccessGas Line Access14......" (362mm) Low Voltage WireAccess Fig. 2 ODGR500 specification and framing dimensions. Moisture Resistance This outdoor fireplace will shed moderate amounts of water, but is not waterproof. Water and condensing water vapor may enter the chase under certain conditions. The fireplace will not perform as an exterior wall. Moisture penetration must be considered for construction that places the fireplace in structure walls or on moisture sensitive surfaces. When installed on exterior walls: MHSC recommends the fireplace chase be constructed outside the structure's weather envelope. Where the platform meets the wall, use a flashing detail similar to that required for attached decks. Chase platforms, including hearths should slope away from the structure at 1/4 in per foot. The fireplace can be shimmed level. When installed on surfaces where water may collect or cause damage: MHSC recommends a slope of 1/8 in to 1/4 in per foot towards the drain port suggested. The fireplace can be shimmed level. Hearths should slope away from the front of the fireplace and chase at 1/8 in to 1/4 in per foot. Metal safety strips must be on top of any combustible hearth materials used for moisture management. Mantels WARNING: A 4" hood must be used if a mantel is to be installed. The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if fitted) and the fireplace. For the correct mounting height and widths refer to Figures 3a and 3b Noncombustible mantels and legs may be installed at any height and width around the appliance. When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent discoloration. ABYZFireplaceCFM146DV Mantel Chart7/5/01 sta Side View Standoff Maintain minimum 3/4" (19 mm) clearance to combustible. ...

Dieses Handbuch ist für folgende Modelle:
Andere Home Zubehör - ODGR400 (1.38 mb)
Andere Home Zubehör - ODGR500 (1.38 mb)
Andere Home Zubehör - ODGR500 (1.38 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien