Volts Watts Amps Hertz Phase NEMA EB-150 120 *EB-150-CAN 120 EB-150-208 208 EB-150-240 240 1500 1500 12.5 12.5 60 60 1 1 5-15P 5-20P 1500 7.3 60 1 6-15P 1500 6.3 60 1 6-15P Models are designed for AC Service. *For Canadian use. HOW TO INSTALL UNIT: TO TURN OFF UNIT: 1. Remove all packing material from inside the Push the POWER switch to “OFF”. cabinet and clean cabinet thoroughly. The yellow light will go out. 2. Install all channels and shelves before the unit is put into operation. 3. Plug the power cord into the proper wall outlet. HOW TO START UNIT: 1. Turn the POWER switch “ON”. The yellow light will turn on. 2. Turn the thermostat to no. 10. 3. Preheat (assuming a “cold” cabinet of 75°F/25°C): To 150°F/65°C takes about 30 mins. To 175°F/79°C takes about 45 mins. To 190°F/88°C takes about 1 hour. 4. Put food into the cabinet. 5. Turn the thermostat to the required temperature. NOTE: No. 8 is about 180°F/82°C w/Light No. 6 is about 155°F/69°C Proper food holding temperature is 140°F / 60°C or higher. Thermometer Switch Thermostat Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • Insulated FL-2257 Banquet Cabinet Rev. 4 (4/07) Page 2 of 4 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING and MAINTENANCE INSTRUCTIONS Models: EB-150 Banquet Warming Cabinet WARNING MAINTENANCE: Hot Unit Removal Instructions 1. Unplug power cord from wall outlet. 2. Lift unit off from the front and rear of cabinet. HOW TO CLEAN THE UNIT: BEFORE Cleaning the Cabinet: 1. Allow cabinet to cool. 2. Remove hot unit from cabinet. 3. Do NOT use abrasives or harsh chemicals. 4. High pressure cleaning is recommended for cabinet exterior. HOW TO CLEAN UNIT: Cleaning hints: 1. Wipe up spills as soon as possible. 2. Clean cabinet regularly to avoid heavy dirt build-up. 3. Make a test spot with cleaner. 4. Follow manufacturer’s directions on cleaner. 5. Do not mix cleaners. 6. Avoid drips and splashes. SOIL CLEANER METHOD CABINET (Stainless Steel) Routine cleaning Stubborn spots and stains Soap, ammonia, or detergent* and water Mild abrasive made for stainless steel 1. Sponge on with cloth 2. Rinse 1. Apply with damp sponge or cloth 2. Rub lightly Burnt-on foods or grease Chemical oven cleaner Follow oven cleaner manufacturer’s directions *Mild detergent include soaps and non-abrasive cleaners Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • Insulated FL-2257 Banquet Cabinet Rev. 4 (4/07) Page 3 of 4 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING and MAINTENANCE INSTRUCTIONS Models: EB-150 Banquet Warming Cabinet TROUBLE-SHOOTING CHART: FAILURE: POSSIBLE CAUSE: 1. Yellow light at switch does NOT light. 1a. Circuit breaker/fuse to wall outlet is blown 1b. Cord is unplugged from wall outlet. 1c. Switch is “OFF.” 2. Unit does not heat. 2a. Thermostat set too low or is “OFF.” 2b. Switch is “OFF.” 3. Unit gets too hot or won’t shut off. 3a. Defective electrical parts. UNPLUG UNIT FROM WALL OUTLET 4. Blower does not work or makes noise. 4a. Defective blower 5. Excess moisture in cabinet. 5a. Open vent 5b. “Slack out” foods from oven or fryer for 5 minutes before putting in hot cabinet. If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400 REPLACEMENT PARTS: DESCRIPTION 120 VOLT 208 VOLT 240 VOLT Power Unit 1254-047 1254-048 1254-049 Blower Kit 0769-005-K 0769-006-K1 0769-006-K1 Heater Kit 0811-244 0811-245 0811-246 Thermostat Kit 0848-062-K 0848-062-K 0848-062-K Thermometer Kit 5238-030-K 5238-030-K 5238-030-K Power Cord 0810-029-02 0810-039-03 0810-039-03 Power Switch 0808-113-K 0808-113-01-K 0808-113-01-K CABINET PARTS: Door Latch 1006-143-K Door Strike 1006-151-K Door Hinge 0519-084 Door Gasket Kit 0861-243 Door Assembly Complete 1221-529 Wire Grid 1170-205 Push Handle 1072-117-K EB-150-CAN: (120V for Canada) Power Unit 1254-050 Power Cord 0810-029-03 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • Insulated Banquet Cabinet Rev. 4 (4/07) GW G3 5 3 4 5-15P PLUG 120V, 15A 5-20P120V 20A 1 2 5 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING and MAINTENANCE INSTRUCTIONS Models: EB-150 Banquet Warming Cabinet FL-2257 Page 4 of 4 AIRHEATER 6-15P PLUG 208V, 15A 240V, 15A BLOWER 4 1 2 AIR POWER THERMOSTAT SWITCH GW Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • (LIGHTED) ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien