Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Blodgett, modell KLT-G Series

Hersteller: Blodgett
Dateigröße: 575.27 kb
Dateiname: KLT-G-man.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment. PURCHASER: Instructions to be followed in the event that the operator of this appliance smells gas must be posted in a prominent location. This information shall be obtained by consulting the local gas supplier. Do not obstruct the flow of combustion and ventilation air. Keep the appliance area free and clear from combustibles. Adequate clearances must be maintained for servicing and proper operation. Do not attempt to operate this unit in the event of a power failure. Intended for commercial use only. Not for household use. This manual should be retained for future reference. TABLE OF CONTENTS DESCRIPTION PAGE Important Notes For Installation and Operation 2 1.0 Service Connections 4 2.0 Installation 5 3.0 Operation 10 4.0 Cleaning Instructions 16 5.0 Maintenance 20 6.0 Service 21 7.0 Troubleshooting 26 Appendix A, Material Safety Data Sheet 29 1.0 SERVICE CONNECTIONS 29 [ 373] JFLKAMINIMUM4[102mm] 8.125 [206] 27.75 [705] 10.5[267] B35[889] 26[660] GC(GLT-20) 6.25[159] (GLT-30...60) 7[178] N5.875[149]3[76] 2[51] H36[914] EMD6[152] FLANGED FOOT DETAIL27/16" [11mm] HOLESON 2.5 [63] B.C. EQUALLY SPACEDODIMENSIONS ARE IN INCHES [MM] Supply gas through 3/4" pipe . A gas shut-off valve must be installed in supply piping convenient and adjacent to appliance. Unless other wise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding wire. COLD WATER: 3/8"(10mm) tubing to faucet (OPTIONAL) HOT WATER: 3/8"(10mm) tubing to faucet (OPTIONAL) DIMENSIONS39415.541949519.516.5152 litresCAPACITY227 litresKLT-60GKLT-40G60 gallons40 gallonsKLT-20GMODEL76 litres20 gallons110843.63115945.63660762mminchesinchesmm3026149959109943.25111543.8845441916.517.882083193076821032C40.63508inchesmm20A48.131222B1019E40.13483D191943F76.556556522.2522.251405841915.57.558423231156108045.542.5G24610H11279J22559K40.51029LM18.3846762924.7530.5775N64825.556222.1372428.5UNITS55.251403KLT-20GMODEL6"-14" (152-356mm) SUPPLY PIPE PRESSURE (W.C.) 11"-14" (279-356mm) PropaneNaturalGAS SUPPLYKLT-40GKLT-60GkW/HR. 23.480,000120,000100,00035.229.3BTU/HR. 2.0 INSTALLATION INSTALLATION CODES AND STANDARDS Installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable. 1. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of . psi (3.5 kPa). . 2. The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than . psi (3.5 kPa). Electrical grounding must be provided in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. The electrical diagram is located on the inside of side panel of left hand console. EXHAUST FANS AND CANOPIES: Canopies are set over ranges, ovens and kettles for ventilation purposes. It is recommended that a canopy extend 6 inches past appliance and be located 7.5 feet from the floor. Filters should be installed at an angle of 45 degrees or more with the horizontal. This position prevents dripping of grease and facilitates collecting the run-off grease in a drip pan, usually installed with the filter. A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish pilot flames. Makeup air openings approximately equal to the fan area will relieve such vacuum. In case of unsatisfactory performance on any appliance, check operation with exhaust fan in the “OFF” position. WALL EXHAUST FAN: The exhaust fan should be installed at least two feet above the vent opening at the top of the unit. CLEARANCES: Adequate clearance must be provided in aisle and at the side and back. Adequate clearances for air openings into the combustion chamber must be provided, as well as for serviceability. SIDES - 0 INCHES BACK - 4 INCHES AT FLUE BOX FLOORS - NON-COMBUSTIBLE INSTALLATION (Continued) All units must be installed in such a manner that the flow of combustion and ventilation air are not obstructed. Provisions for an adequate air supply must also be provided. Do not obstruct side of th...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien