Anleitung Grindmaster, modell TEA-300
Hersteller: Grindmaster Dateigröße: 148.55 kb Dateiname: fc14f134-13a5-4e08-9194-f004a732e1eb.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
. . . . . . . . . . . . . . . . . . . . . . .2 Set Up/Position . . . . . . . . . . . . . . . . . . . . . . . .3 Water Hook-Up . . . . . . . . . . . . . . . . . . . . . . . . .3 Electrical Requirements . . . . . . . . . . . . . . . .3-4 Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . .4 Use Control Functions . . . . . . . . . . . . . . . . . . .4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . .5-6 Cleaning Procedures . . . . . . . . . . . . . . . . . .6-7 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8 Troubleshooting Guide . . . . . . . . . . . . . . . .9-10 Exploded View . . . . . . . . . . . . . . . . . . . . . .11-12 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .13 TEA-300 Prior authorization must be obtained from Grindmaster Corporation for all warranty claims. Grindmaster Corporation 4003 Collins Lane Louisville, Kentucky 40245 USA (502) 425-4776 800-695-4500 (800) 568-5715 (technical service only) FAX (502) 425-4664 Grindmaster Corporation, 1999 1103 Form # AM-325-04 PRINTED IN THE USA Part # A090-103 Warning Labels The following warning and caution statements are contained in different sections of this manual. Please read this manual and follow all safety precautions when operating or servicing this equipment. ! WARNING: ELECTRIC SHOCK HAZARD ONLY QUALIFIED SERVICE PERSONNEL SHOULD PERFORM INSTALLATION OF THIS APPLIANCE. IMPROPER INSTALLATION COULD RESULT IN ELECTROCUTION. CAUTION: HOT LIQUID HAZARD ! WATER USED FOR BREWING TEA IS VERY HOT. USE CAUTION WHEN BREWING, POURING, OR TRANSPORTING HOT TEA. NEVER ATTEMPT TO MOVE THE BREWER WITHOUT FIRST DRAINING THE WATER TANK. ACCIDENTAL SPILLS MAY RESULT IN SEVERE BURNS. ! WARNING: BURN HAZARD HOT LIQUIDS AND SURFACES ARE PRESENT IN THIS EQUIPMENT. TO AVOID BURNS USE CAUTION WHEN CLEANING. RINSE HOT PARTS WITH COLD WATER BEFORE CLEANING. USE GLOVES OR HEAVY CLOTH WHEN REMOVING HOT PARTS FROM BREWER. ! WARNING: ELECTRIC SHOCK HAZARD NEVER USE THE GROUND CONDUCTOR AS A NEUTRAL. THIS COULD CAUSE ELECTROCUTION. ! CAUTION: HOT LIQUID HAZARD TEA BASKET CONTAINS VERY HOT LIQUID UNTIL THE DRIP-THROUGH IS COMPLETED. EARLY REMOVAL OF THE BASKET COULD RESULT IN BURNS. ! WARNING: ELECTRIC SHOCK HAZARD DANGEROUS ELECTRIC VOLTAGES ARE PRESENT NEAR ADJUSTABLE COMPONENTS. ONLY QUALIFIED SERVICE PERSONNEL SHOULD MAKE ADJUSTMENTS. WARNING: BURN HAZARD ! HOT LIQUIDS AND SURFACES ARE PRESENT IN THIS EQUIPMENT. TO AVOID BURNS USE CAUTION WHEN SERVICING EQUIPMENT. ALLOW UNIT TO COOL BEFORE SERVICING EQUIPMENT. American Metal Ware® Tea Brewers Page 2 ! ! WARNING: ELECTRIC SHOCK HAZARD ONLY QUALIFIED SERVICE PERSONNEL SHOULD PERFORM INSTALLATION OF THIS APPLIANCE. IMPROPER INSTALLATION COULD RESULT IN ELECTROCUTION. Set-Up / Position 1. Position the brewer on a strong, stable counter top or table. 2. Check the level front to back and side to side. Adjust the legs to the correct level. 3. See rough-in drawing in this manual for dimensions and locations of electrical and water input. Water Hook-Up IMPORTANT WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY CONNECTED TO A POTABLE WATER SUPPLY SHALL BE SIZED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL CODES. 1. The water line should be a 1/4" (6.35 mm) copper or flexible water line to prevent strain. Do not use low temperature plastic tubing. The connector on the fill valve is a 1/4" (6.35 mm) male flare fitting. 2. Water line pressure must be from 30 to 70 psi. 3. Install a shut-off valve near the brewer. 4. Install a backflow prevention device that conforms to ASSE Standard #1024. IMPORTANT THIS EQUIPMENT IS TO BE INSTALLED WITH ADEQUATE BACKFLOW PROTECTION TO COMPLY WITH APPLICABLE FEDERAL, STATE AND LOCAL CODES. 5. Installing a filtering system can improve the taste of brewed tea and extend the life of the brewer. The use of a filter is especially important if your water has a high calcium (lime), chlorine, or iron content. Contact our Technical Service department to select the filter for your water conditions. Electrical Requirements IMPORTANT THE PERSON INSTALLING THIS APPLIANCE IS RESPONSIBLE FOR ENSURING THAT ELECTRICAL CONNECTIONS MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE, STATE AND ANY LOCAL CODES. 1. The electric ratings for your brewer are printed on its nameplate. The electrical rating is one of the following: • 120 Volt, 15 Amp, 1 Phase • 120/208-240 Volt, 20 Amp, 1 Phase, 4 supply wires 2. The brewer should be connected to its own circuit with a fused disconnect switch or a circuit breaker near the brewer. American Metal Ware® Tea Brewers Page 3 Electrical Requirements (cont.) ! WARNING: ELECTRIC SHOCK HAZARD NEVER USE THE GROUND CONDUCTOR AS A NEUTRAL. THIS COULD CAUSE ELECTROCUTION. 3. The body of the brewer must be grounded. A ground lug is provided for this purpose. Initial Start-Up 1. Turn on the water supply to the brewer. Chec...