Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Alto-Shaam, modell Drawer Warmers 500-3DN

Hersteller: Alto-Shaam
Dateigröße: 89.71 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


ANSI/NSF 4 ® ADDITIONAL FEATURES & OPTIONS Built-in Trim kit Caster Stand Assembly Leg Stand Assembly Drawer Assembly with vents ¦ Specify on order W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 • U.S.A. PHONE: 262.251.3800 800.558.8744 U.S.A./CANADA FAX: 262.251.7067 800.329.8744 U.S.A. ONLY WEBSITE: PRINTED IN U.S.A. DUE TO ONGOING PRODUCT DEVELOPMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. #18A - 10/05 500-1DN, 500-2DN, 500-3DN DRAWER WARMERS 500-1DN500-2DN500-3DN1-11/16" (42mm) CL16-7/16" (418mm) 50-7/8" (1291mm) 28-1/8" (714mm) 11-11/16" (296mm)18-7/8" (479mm)26-3/16" (663mm) ELECTRICAL CONNECTIONELECTRICAL CONNECTIONHI-LO Switch available only on 500-1DN and 500-2DN. 6-3/4" (171mm) FOR LEG STAND OR CASTER STAND ASSEMBLY29-15/16" (761mm) HANDLE DIMENSIONS: H x W x D 500-1DN EXTERIOR: 11-11/16" x 16-7/16" x 29-15/16" (296mm x 418mm x 761mm) 500-2DN EXTERIOR: 18-7/8" x 16-7/16" x 29-15/16" (479mm x 418mm x 761mm) 500-3DN EXTERIOR: 26-3/16" x 16-7/16" x 29-15/16" (663mm x 418mm x 761mm) Pan size: (EACH DRAWER) 12" x 20" x 6" (305mm x 508mm x 152mm) GN 1/1 ELECTRICAL VOLTAGE PHASE CYCLE/HZ AMPS kW 120 1 60 LOW 4.0 HIGH 8.5 0.5 1.05 NEMA 5-15P 15A, 125V PLUG 208-240at 208 1 at 240 1 50/60 4.0 50/60 4.5 0.8 1.05 NEMA 6-15P 15A, 250V PLUG FOR USA ONLY 230 1 50/60 4.2 0.97 CEE 7/7, 220-230V PLUG PRODUCT CAPACITY 20 lbs (9 kg) MAXIMUM • EACH DRAWER (34 BAKED POTATOES, 50 DINNER ROLLS) WEIGHT 500-1DN 500-2DN 500-3DN NET 67 lb (30 kg) 100 lb (45 kg) EST. 130 lb (59 kg) EST. SHIP 75 lb (34 kg) 112 lb (51 kg) 145 lb (66 kg) CRATE 15" X 21" X 33" 22" X 21" X 33" 29" X 21" X 33" DIMENSIONS : (H x W x D) (381 x 533 x 838 mm) (559 x 533 x 838 mm) (737 x 533 x 838 mm) DOMESTIC SHIPMENTS ONLY INSTALLATION REQUIREMENTS CLEARANCE REQUIREMENT (FOR VENTILATION) Drawer warmer must be installed level, and must not be installed in any area where it may be affected by steam, grease, dripping water, high temperatures, or any other severely adverse conditions. Minimum: 3-inches (76mm) at the back, 2-inches (51mm) at the top, and 1-inch (25mm) at both sides. On-site venting for proper airflow must also be provided for built-in counter installations. OPTIONS & ACCESSORIES Built-in Trim Kit ¦ 500-1DN 44225 ¦ Caster Stand Assembly 55534 ¦ Drawer Assembly with vents 55537 ¦ 500-2DN 44227 ¦ Leg Stand Assembly 55535 ¦ 500-3DN 44229 ¦ Perforated pan grid, 12" x 20" (305mm x 508mm) 16642 ® W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 • U.S.A. PHONE: 262.251.3800 800.558.8744 U.S.A./CANADA FAX: 262.251.7067 800.329.8744 U.S.A. ONLY WEBSITE: #18A -10/05 DUE TO ONGOING PRODUCT DEVELOPMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. PRINTED IN U.S.A. ...

Dieses Handbuch ist für folgende Modelle:
Andere Küchengeräte - Drawer Warmers 500-1DN (89.71 kb)
Andere Küchengeräte - Drawer Warmers 500-2DN (89.71 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien