Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung Henny Penny, modell HUMIDIFIED COUNTER WARMER HCS-2

Hersteller: Henny Penny
Dateigröße: 950.52 kb
Dateiname: HCW_OM_FINAL.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The panel will fall into your hand. See photo at left. 2. Remove the light bulb. 3. Replace the light bulb with a Westinghouse #60A19/35, 130 Volt bulb. If this bulb is not available, a standard 60 watt bulb will work until a long life bulb can be obtained. 4. Replace the glass panel. 2-6 103 Model HCS-2/HCW-3/HCW-5/HCW-8 2-10. CABINET DIMENSIONS Model HCS-2 Model HCW-3 1006 2-7 Model HCS-2/HCW-3/HCW-5/HCW-8 2-10. CABINET DIMENSIONS (Continued) Model HCW-5 2-8 1006 Model HCS-2/HCW-3/HCW-5/HCW-8 SECTION 3. OPERATING INSTRUCTIONS 3-1. INTRODUCTION This section provides operating procedures for the heated display cabinets. The Introduction, Installation and Operation sections should be read, and all instructions should be followed before operating the cabinet. 3-2. OPERATING CONTROLS Figures 3-1 through 3-12 identify and describe the function of all the operating controls and the major components of the cabinet. 103 3-1 Model HCS-2/HCW-3/HCW-5/HCW-8 3-2. OPERATING CONTROLS (Continued) Figure 3-2 Figure 3-1 Figure 3-3 Figure 3-4 Figure 3-5 Figure 3-6 3-2 103 Model HCS-2/HCW-3/HCW-5/HCW-8 3-2. OPERATING CONTROLS (Continued) Figure 3-8 Figure 3-7 Figure 3-9 Figure 3-10 Figure 3-11 Figure 3-12 103 3-3 Model HCS-2/HCW-3/HCW-5/HCW-8 3-2. OPERATING CONTROLS (Continued) Fig. No. Item No. Description Function 3-1 1 Water Valve An electrical solenoid valve energized by the float switch or the water control switch (in manual position) that allows water to flow into the water pan 3-1 2 Water Strainer A filter to prevent particles plugging the water valve 3-1 3 Contactor The relay that directs power to the water heaters 3-1 4 Relay Shuts the heat off to the water pan when a low water condition is sensed by the float switch 3-2 5 Radiant Heater A long tubular heater mounted in a reflector located in the ceiling panel of the unit 3-3 6 High Temperature Limit A safety device mounted to the bottom of the water pan which detects an over temperature condition if the water pan runs dry 3-4 7 Perforated Bun Pan Used over the water pan to allow the humidity to pass thru the chicken 3-5 8 Water Pan Grid A grid that sets in the water pan to prevent a bun pan from dropping into the water when being lifted out 3-6 9 Pan Support Top Tilts the bun pans used in the top toward the customer side of the unit 3-7 10 Light Bulb A 60 watt rated, long-life bulb that should be replaced by the same wattage bulb 3-8 11 Lamp Socket A high temperature ceramic socket for holding the light bulb 3-9 12 Tinted Glass Specially tempered colored glass with a thin film of silicone that protects the light bulbs as well as color the light 3-4 103 Model HCS-2/HCW-3/HCW-5/HCW-8 3-2. OPERATING CONTROLS (Continued) Fig. No. Item No. Description Function 3-10 13 Water Control Switch A three-position switch with center position being OFF; in the position marked AUTOMATIC (up), the water level in the unit will be controlled by the float switch; in the position marked MANUAL (down), the water valve is opened directly by the switch; the MANUAL position is spring loaded so that the water valve will close when the switch is released 3-10 14 Water Light A light operated directly by the float switch, which when illuminated, indicates low water conditions no matter what position the water control switch is in 3-10 15 Thermometer Indicates the water temperature 3-10 16 Water Thermostat An electro-mechanical device used to regulate the water temperature 3-10 17 Power Switch A two-position, three pole switch used to turn on and off the heat and water control systems 3-10 18 Power Light A light, when illuminated, indicating when the power switch is on and the heat and water system controls are energized; if the power light goes out during normal operation, this means the water pan high temperature limit has opened indicating that the unit is out of water 3-10 19 Radiant Heat Infinite Regulator A time proportioning controller, which means the higher the number setting, the greater percentage of time the radiant heat will be on 3-10 20 Light Switch A two-position, two pole switch used to turn the lights ON and OFF 3-10 21 Light Fuse Holder A 15 amp protective device for the lighting circuit, that must be replaced by a fuse of the same size and rating 103 3-5 Model HCS-2/HCW-3/HCW-5/HCW-8 3-2. OPERATING CONTROLS (Continued) Fig. No. Item No. Description Function3-11 22 Float Switch An electro-mechanical sensing device used to automatically control the water level in the water pan; the float switch can be inactivated by the water control switch; the float switch illuminates the low water light when it senses a low water condition 3-12 23 Water Heater Two flat strip heaters, attached to the bottom of the water pan, which measure approximately 3” wide by 25” long, and are rated at 1020 watts each 3-3. START-UP Before using, the Henny Penny Heated Display Cabinet should be thoroughly cleaned as indicated in the Shut-Do...

Dieses Handbuch ist für folgende Modelle:
Andere Küchengeräte - HUMIDIFIED COUNTER WARMER HCS-5 (950.52 kb)
Andere Küchengeräte - HUMIDIFIED COUNTER WARMER HCW-2 (950.52 kb)
Andere Küchengeräte - HUMIDIFIED COUNTER WARMER HCW-3 (950.52 kb)
Andere Küchengeräte - HUMIDIFIED COUNTER WARMER HCW-5 (950.52 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien