Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Zebra Technologies, modell ZEBRA XI4TM

Hersteller: Zebra Technologies
Dateigröße: 6.01 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Default: OFF Selections: OFF, VER-RPRNT ERR, VER-THRUPUT • OFF: The verifier port is off. • VER-RPRNT ERR: Label reprinted if verifier detects an error. If a bar code is near the upper edge of the label, the label is fed out far enough to be verified and then backfed to allow the next label to be printed and verified. • VER-THRUPUT: Allows greatest throughput but may not indicate a verification error immediately upon detection. May print from one to three labels before an error is recognized and printing stops. To change the value shown: 1. Press PLUS (+) or MINUS (-) to scroll through the options. Set Applicator Port Mode Determines the action of the applicator port. Note • Set this value as suggested by the applicator manufacturer. Default: OFF Selections: OFF, MODE 1, MODE 2, MODE 3, MODE 4 • OFF: The applicator port is off. • MODE 1: Asserts the ~END_PRINT signal low while the printer is moving the label forward. • MODE 2: Asserts the ~END_PRINT signal high while the printer is moving the label forward. • MODE 3: Asserts the ~END_PRINT signal low for 20 milliseconds when a label has been completed and positioned. Not asserted during continuous printing modes. • MODE 4: Asserts the ~END_PRINT signal high for 20 milliseconds when a label has been completed and positioned. Not asserted during continuous printing modes. To change the value shown: 1. Press PLUS (+) or MINUS (-) to scroll through the options. P1009874-002 Xi4™/RXi4™ User Guide Configuration Standard Control Panel Parameters Table 8 • Printer Parameters (Sheet 19 of 22) Language/Parameter Action/Explanation Set Applicator Error Signal When Printer Pauses When this option is enabled and the printer is paused, the printer sets the applicator error state. Default: ENABLED Selections: ENABLED, DISABLED To change the value shown: 1. Press PLUS (+) or MINUS (-) to toggle between the options. Select Start Print Signal This parameter determines how the printer reacts to the Start Print Signal input on pin 3 of the applicator interface connector at the rear of the printer. Caution • Start Print Signal is set by the applicator manufacturer and should not be changed unless the factory defaults have been reloaded. Please make a note of it. While other choices are valid, the printer must be returned to its designated setting for it to work properly. Default: PULSE MODE Selections: PULSE MODE, LEVEL MODE • PULSE MODE—Labels print when the signal transitions from HIGH to LOW. • LEVEL MODE—Labels print as long as the signal is asserted LOW. To change the value shown: 1. Press PLUS (+) or MINUS (-) to toggle between the options. Select Resynch Mode This parameter determines how the printer reacts if the label synchronization is lost and the label top is not where expected. Default: FEED MODE Selections: FEED MODE, ERROR MODE • FEED MODE—If the label top is not where expected, the printer feeds a blank label to find the label top position. • ERROR MODE—If the label top is not where expected, the printer stops, enters Pause mode, displays the message Error Condition Feed Label, flashes the ERROR light, and asserts the Service Required signal (pin 10 on the Applicator Interface Connector). To resynch the media to the top of the label in Error mode, press PAUSE to exit Pause mode. The ERROR light stops flashing, and the Service Required signal is deactivated. The action of the printer is determined by the Head Close configuration selection (see Select Head Close Option on page 106). To change the value shown: 1. Press PLUS (+) or MINUS (-) to toggle between the options. 1/7/10 Xi4™/RXi4™ User Guide P1009874-002 Configuration Standard Control Panel Parameters Table 8 • Printer Parameters (Sheet 20 of 22) Language/Parameter Action/Explanation Set Reprint Mode When reprint mode is enabled, you can reprint the last label printed either by issuing the ~PRZPL command or by pressing MINUS (-) on the control panel. Default Value: DISABLED Selections: ENABLED, DISABLED To change the value shown: 1. Press PLUS (+) or MINUS (-) to toggle between the options. See next column View Sensor Settings These parameters are automatically set during the calibration procedure and should be changed only by a qualified service technician. Refer to the Programming Guide for ZPL, ZBI, Set-Get-Do, Mirror, and WML for information on these parameters. To skip these parameters: 1. Press NEXT/SAVE to skip each of the following parameters: P1009874-002 Xi4™/RXi4™ User Guide Configuration Standard Control Panel Parameters Table 8 • Printer Parameters (Sheet 21 of 22) Language/Parameter Action/Explanation Select Format Convert Selects the bitmap scaling factor. The first number is the original dots per inch (dpi) value; the second, the dpi to which you would like to scale. Default Value: NONE Selections: NONE, 150 > 300, 150 > 600, 200 > 600, 300 > 600 To change the value shown: 1. Press PLUS (+) or MINUS (-) to scroll through the options. Select Idle Display This parameter selects the LCD options...

Dieses Handbuch ist für folgende Modelle:
Drucker - ZEBRA RXI4TM (6.01 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien