Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung American Sensor, modell ESA5010

Hersteller: American Sensor
Dateigröße: 68.68 kb
Dateiname: ESA5011_USmanual.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


ground fault interrupter. It is highly recommended that smoke 3. Press and hold the test button until the alarm sounds. NOTE: It lightning, children playing with matches, or arson. • In the center of a room or hallway: As it is impossible to predict alarms be wired on a separate circuit (one with no other lights or may be necessary to press the test button for up to 20 seconds for anthe source of a fire. If it is necessary to place the alarm on a wall, appliances) to ensure maximum reliability of AC power supply. For alarm to sound. An alarm is indicated by 3 loud beeps repeating • Smoke alarms are not substitutes for property, disability, life or always locate the top of the smoke alarm 4-6 inches (10-15 cm) every 5 seconds. Alarm may continue to sound for up to 10 seconds other insurance of any kind. Home owners and renters should from the ceiling. Smoke alarm after button is released. (NOTE: Model ESA5011: Pressing the test SMOKE ALARM MANUAL continue to insure their lives and property. Consult your button activates the relay.) Ionization Type Models - 120 VAC Hardwire insurance agent. that may interfere with the path of smoke to an alarm. They may • As needed: To compensate for closed doors and other obstacles 4. At least once a week, press the test button and hold until the alarmalso prevent occupants on one side of a closed door from hearing sounds, then release. • Smoke alarms have limited lives. One or more of the many an alarm on the other side of the door. NOTE: Multiple Station Only: • Model ESA5010 -120 Volt AC Hardwire Smoke Alarm. components could fail at any time. Therefore, test your smoke • Models ESA5010 and ESA5011 - Hardwire models can be 5. Test each alarm separately in the system. alarm weekly. Clean and take care of it as described in this • Model ESA5011 -120 Volt AC Hardwire with Relay located in any area of the home. 6. Determine that the initiating alarm triggers other alarms in the system. READ “CAPABILITIES AND LIMITATIONS OF SMOKE manual. Repair or replace the smoke alarm when it fails to test Important information about your smoke alarm properly. Your smoke alarm should be replaced if it is ten years mounting platequick disconnectpower connector paper gasket (not shown-fits in between) 7. Model ESA5011: Pressing the test button activates the relay. ALARMS” in Section 1 of this manual. • Install alarms outside of every bedroom area and on every floor of old. Your local fire department or insurance your home. Please refer to Section 3 “Where to Locate Smoke Test smoke alarm operation after vehicle has been • Ionization Technology vs. Alarms” for details. Dining Kitchen Bedroom Bedroom BedroomLiving Room BedroomKitchenDining in storage, before each trip, and at least once per installation of smoke alarms in Dwelling Units, it is important to Photoelectronic Technology WARNING ! follow the National Electrical Code and local codes. week during use. Smoke Alarms • Test the alarm weekly by pressing and holding the test button for TV Room 1. Electricity must be turned off at service entrance before up to 20 seconds until the alarm sounds. Living Room Bedroom There are two different types of smoke alarm technology currently in general use: Ionization and photoelectronic. While both types of technology are suitable for general residential use, an ionization alarm will normally respond faster to fast flaming fires, while a photoelectronic alarm may be more sensitive to detecting slow smoldering fires. Because home fires develop in different ways and are often unpredictable in their growth, it is impossible to predict which type of alarm will provide the earliest warning. For best home protection install at least one photoelectronic and one ionization smoke alarm on each level of your home. Models ESA5010 and ESA5011 are ionization type smoke alarms. A photoelectronic smoke alarm senses smoke using an electronic photo receptor to sense the scattering of light by smoke particles. 2. SAFETY TIPS Properly installed and maintained smoke alarms are an essential part of a good home fire safety program. Your fire safety program should also include a review of fire hazards and the elimination of dangerous conditions whenever possible. Consider the following tips: • Use smoking materials properly. Never smoke in bed. • Keep matches and cigarette lighters away from children. • Store flammable materials in proper containers. Never use them near an open flame or sparks. • Keep electrical appliances in good condition. Do not overload electrical circuits. • Keep stoves, fireplaces, chimneys, and barbecue grills grease free. Make sure they are properly installed and away from any combustible materials. • Keep portable heaters and open flames such as candles away from combustible material. • Do not allow rubbish to accumulate. • Keep a supply of extra batteries on hand for your battery powered smoke alarms. • Do not stand too close to the alarm when the unit is in alarm as the loud horn could damage your...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien