• Tuck the orange wire inside the junction box. It is used for interconnect only. INTERCONNECTED UNITS ONLY: Strip off about 1/2” (12 mm) of the plastic coating on the orange wire on the power connector. • Connect the white wire on the power connector to the neutral wire in the junction box. • Connect the black wire on the power connector to the hot wire in the junction box. • Connect the orange wire on the power connector to the interconnect wire in the junction box. Repeat for each unit you are interconnecting. Never connect the hot or neutral wires in the junction box to the orange interconnect wire. Never cross hot and neutral wires between Alarms. ELECTRICAL SHOCK HAZARD. Do not restore power until all Smoke Alarms are completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death. 6. Make sure the Smoke Alarm is receiving AC power. Under normal operation, the Green power indicator light will shine continuously. 7. If the Green power indicator light does not light, TURN OFF POWER TO THE JUNCTION BOX and recheck all connections. If all connections are correct and the Green power indicator still does not light when you restore the power, the unit should be replaced immediately. 8. Test each Smoke Alarm. Press and hold the Test/Silence button until the unit alarms. When testing a series of interconnected units you must test each unit individually. Make sure all units alarm when each one is tested. If any unit in the series does not alarm, TURN OFF POWER and recheck connections. If it does not alarm when you restore power, replace it immediately. STAND-ALONE ALARM ONLY: • If you are only installing one Smoke Alarm, restore power to the junction box. INTERCONNECTED UNITS ONLY: • If you are interconnecting multiple Smoke Alarms, repeat steps 1-5 for each Smoke Alarm in the series. When you are finished, restore power to the junction box. Special Requirements For Interconnected Smoke Alarms • Failure to meet any of the above requirements could damage the units and cause them to malfunction, removing your protection. • AC and AC/DC Smoke Alarms can be interconnected. Under AC power, all units will alarm when one senses smoke. When power is interrupted, only the AC/DC units in the series will continue to send and receive signals. AC powered Smoke Alarms will not operate. Interconnected units can provide earlier warning of fire than stand-alone units, especially if a fire starts in a remote area of the dwelling. If any unit in the series senses smoke, all units will alarm. To determine which Smoke Alarm initiated an alarm, see table: On Initiating Alarms Red LED flashes rapidly On All Other Alarms Red LED is Off Interconnect units within a single family residence only. Otherwise all households will experience unwanted alarms when you test any unit in the series. Interconnected units will only work if they are wired to compatible units and all requirements are met. This unit is designed to be compatible with: First Alert® Smoke Alarm Models SA4120, SA4121B, SA100B and BRK Electronics® Smoke Alarm Models 100S, 2002RAC, 4120, 4120B, 4120SB, 5919; BRK Electronics® Heat Alarm Models HD6135F, HD6135FB; Smoke/CO Alarm Model SC6120B; Relay Module RM3. Continued... OPTIONAL LOCKING FEATURES The locking features are designed to discourage unauthorized removal of the battery or Alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or Alarm removal is not a concern. These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting bracket. You can choose to use either feature independently, or use them both. Tools you will need: • Needle-nose pliers or utility knife • Standard Flathead screwdriver. Both locking features use locking pins, which are molded into the mounting bracket. Using needle-nose pliers or a utility knife, remove one or both pins from the mounting bracket, depending on how many locking features you want to use. To permanently remove either lock, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock. TO LOCK THE BATTERY COMPARTMENT (Model 7010B Only) Do not lock the battery compartment until you have installed the battery and tested the battery back-up. 1. Push and hold Test/Silence button until the alarm sounds: 3 beeps, pause, 3 beeps, pause. If the unit does not alarm during testing, DO NOT lock the battery compartment! Install a new battery and test again. If the Smoke Alarm still does not alarm, replace it immediately. 2. Using needle-nose pliers or a utility knife, detach one locking pin from the mounting bracket. 3. Push the locking pin through the hole near the battery drawer on the back of the Smoke Alarm. TO UNLOCK THE BATTERY COMPARTMENT (Model 7010B Only) Once the Smoke Alarm is installed, you must disconnect it from the AC power before unlocking the battery c...
Dieses Handbuch ist für folgende Modelle:Alarm - 7010 (561.7 kb)