Anleitung American Sensor, modell SA360

Hersteller: American Sensor
Dateigröße: 144.8 kb
Dateiname:
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


ORANGE Interconnect ANY KIND. APPROPRIATE COVERAGE IS YOUR DO NOT PLACE SMOKE ALARMS: RESPONSIBILITY. CONSULT YOUR INSURANCE AGENT. • In turbulent air from fans, doors, windows, etc. The rapid air •Relay Connection This warranty gives you specific legal rights and you may have other movement may prevent combustion particles from entering the rights which may vary from province to province. Model ESA5011 only - The ESA5011 smoke alarm provides one alarm. Form C, normally open/normally closed contact which is activated • In dead air spaces such as at the peak of an “A” frame ceiling. Units may be returned to point of purchase according to retailers MULTIPLE STATION on alarm. “Dead air” at the top may prevent smoke from reaching the alarmIntegral relay - The ESA5011 comes complete with voltage free in time to provide early warning. In rooms with simple sloped, contacts, allowing the unit to be used with a variety of auxiliary peaked or gabled ceilings, install smoke alarms on the ceiling equipment. The contacts remain closed for the whole period of the 90 cm (3 feet) from the highest point of the ceiling. alarm. Once the alarm ends, the contacts open. Note: For complex ceiling structures, consult a safety expert for the number of alarms required and the best locations. • In very hot or cold areas where the temperature exceeds 380C CONTENTS OF THIS MANUAL (1000F) or falls below 50C (400F). 1. CAPABILITIES AND LIMITATIONS OF SMOKE ALARMS • Less than 15 cm (6 inches) from the wall when mounted on the 2. SAFETY TIPS ceiling. 3. WHERE TO LOCATE SMOKE ALARMS Nuisance alarms could result when smoke alarms are located where 4. NFPA RECOMMENDATIONS interference may occur with the sensing chamber. To avoid nuisance alarms, DO NOT place smoke alarms: 5. LOCATIONS TO AVOID • In high humidity areas such as bathrooms and attics. Place smoke alarms at least 3 meters (10 feet) away from bathrooms. 6. INSTALLATION AND TESTING 7. MAINTENANCE AND TROUBLESHOOTING • In insect-infested areas. 8. LIMITED WARRANTY • In poorly ventilated kitchens or garages. • In very dusty and dirty areas. 1. CAPABILITIES AND LIMITATIONS OF SMOKE ALARMS • Near fluorescent lights. Place smoke alarms at least 1.5 meters American Sensors Inc. smoke alarms are designed to provide early (5 feet) from fluorescent lights. warning of fire and smoke at reasonable cost. Early warning can mean the difference between a safe escape and no escape at all. WARNING ! This smoke alarm is suitable for residential use. While smoke alarms can provide invaluable protection for you and It is not to be connected to a commercial or your family, they do have limitations. industrial fire alarm panel. • Smoke alarms cannot work without power. Battery operated alarms will not work without proper batteries, with dead batteries 6. INSTALLATION AND TESTING or if batteries are not properly installed. AC powered alarms will This model has an optional Locking Key to better secure the alarm not work if their AC power supply is cut off by an electrical fire, to inhibit unauthorized removal. If securing the alarm is a concern, an open fuse, a circuit breaker or any other reason. remove and save the “Locking Key” from the back plate with needle If you are concerned about the reliability of either battery or your nosed pliers before installing the alarm. See point 12 in this section AC power supply for any of the above reasons, you should install for more details on this feature. in your home both AC and battery powered smoke alarms for added security. American Sensors Inc. also offers the SA379 A. Installation model which is AC powered with battery back-up. Mount to any standard or rectangular junction box with a minimum • Smoke alarms are incapable of sounding the alarm until smoke depth of 2.5 cm (1 inch). reaches the sensing chamber. Anything preventing smoke from Model SA360- 120 VAC, 60Hz, 50mA operation reaching the alarm may delay or prevent an alarm. A smoke alarm Model ESA5011- 120 VAC, 60Hz, 70mA operation Your local fire department may be able to offer you additional ideas cannot detect fire in the walls, chimney or roof unless and until a WARNING: Wiring should only be installed by a licensed for safety and escape plans in the home. significant amount of smoke reaches the alarm. A closed door may electrician in accordance with the Canadian Electrical Code and prevent smoke from reaching an alarm on the other side of the local codes. door. A smoke alarm may not sense a fire on another floor of a 3a. WHERE TO LOCATE SMOKE ALARMS WARNING: The circuit used to power the smoke alarm must be a home. For example, a basement smoke alarm may not detect a fire As a minimum, smoke alarms should be located between sleeping 24 hour voltage circuit that cannot be turned off by a switch or a which started on the first or second floor. areas and potential sources of fire such as a kitchen, heated garage or ground fault interrupter. It is highly recommended that smoke basement. In single storey...

Dieses Handbuch ist für folgende Modelle:
Alarm - ESA5011 (144.8 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien