Login:
Stimmen - 5, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Sierra Monitor Corporation, modell 2060

Hersteller: Sierra Monitor Corporation
Dateigröße: 89.31 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The factory setpoint for R12 is 500 ppm while the setpoint for R134a is 50 ppm. See the specifications for more details. Temperature Range The Model 2050 and 2060 have temperature compensated circuitry to provide stabilization in temperatures ranging from -4o to 158oF. Semiconductor-Type Sensor A solid-state semiconductor-type sensor and associated electronic circuitry ensure trouble-free, long-term operation. There are no pumps, filters, or chemical cells to replace or maintain. Except periodic calibration to verify the alarm setting, no periodic maintenance is required after installation. The user may adjust the alarm level by using a different calibration gas concentration. Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 FAX: (408) 262-9042 Model 2050/2060 Ammonia and Halocarbon Gas Monitors SPECIFICATIONS Indicators: Sensor Type: Alarm Setpoint:: 2050 Series 2060 Series Green LED for Monitor “ON”/Safe Red LED for Alarm Solid-state metal oxide semiconductor 100 ppm NH3 R11 500 ppm R12 500 ppm R22 50 ppm R113 100 ppm R123 70 ppm R134a 50 ppm R141b 40 ppm R142b 40 ppm R500 40 ppm R502 70 ppm Calibration Gas: 2050 Series 2060 Series Power: Signal Output:: 2050-00/2060-00 Response Time: 80 ppm Hydrogen (H2) 150 ppm Carbon Mon2oxide (CO) 9-24 VDC, 250 mA Nominal 5 volt DC, source 25 mA. SAFE and ALARM Signals 0.5 AMP dry contact, 100 VDC, 130 VAC and audible Less than 90 seconds Operating Temperature Range: -4 to 158oF (-20° to 70oC) User adjustable with calibration over range of 50 to 500 ppm Enclosure Material: Size: Weight: Polystyrene 5.6 x 3.1 x 2.1 in. (14.2 x 7.9 x 5.3 cm) 0.3 lb (0.15 Kg) ORDERING INFORMATION 2050-00 Ammonia Gas Monitor 2060-00 Refrigerant/Halocarbon Gas Monitor 1200-26 Gas Sensor Calibrator w/2 gas cylinders of calibration gas 1290-10 Gas Cylinder - Carbon Monoxide, 150 ppm 1290-11 Gas Cylinder - Hydrogen, 80 ppm OTHERPRODUCTS 2102-00 Dual Channel Alarm Panel ISO 9001 REGISTERED QUALITY SYSTEM Outline and Dimensions Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 FAX: (408) 262-9042 Visit our website: E-mail: sales@sierramonitor.com © 2010 Sierra Monitor Corp. Rev.A-7/10...

Dieses Handbuch ist für folgende Modelle:
Alarm - 2050 (89.31 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien