Anleitung Zusammenfassung
12. If the alarm is interconnected to other CO alarms, press and hold the TEST/RESET button until the red light turns on. Other interconnected alarms also will beep four times followed by 5 seconds of silence. The red ALARM light on other alarms will not light during this test. If the alarm is interconnected with smoke or heat alarms, the smoke and heat alarms will remain silent. 13. Two self-adhesive labels have been provided with instructions indicating what to do if the alarm sounds. Add the phone numbers of your emergency services provider and a qualified technician to each label. Place one of the labels in a visible area next to the alarm, and place the other label near a source of fresh air which will be used as a gathering place if the alarm sounds. How to Operate Your CO Alarm This carbon monoxide alarm has been evaluated by UL and meets the applicable UL standards and requirements. FIGURE 7 This CO alarm has a three light and sound alarm system: ON SERVICE ALARM: MOVE TO FRESH AIR CARBON MONOXIDE ALARM On Green indicator constantly ON indicates unit is receiving AC (Power on/ operating) power. Service Amber indicator flashing and alarm horn beeping every (Problem with Alarm) thirty seconds indicates unit fault. Press and release the TEST/RESET button. If the alarm returns to displaying the fault signal, the CO alarm is not operating properly. REPLACE THE CO ALARM IMMEDIATELY. SEE THE WARRANTY INFORMATION AT THE END OF THIS MANUAL. Alarm Red indicator flashes and alarm horn sounds four fast (Dangerous CO levels) beeps and then is quiet for 5 seconds. When the CO concentration builds to a level that is equal to 70 ppm or greater for the duration identified within the standard, the following will occur: • The ALARM light and sound signals will activate. See the WHAT TO DO IF YOUR ALARM SOUNDS section of this manual for important action steps to be taken. • If you wish to press the TEST/RESET button during this time, the alarm will become quiet for up to six minutes. The ALARM signals will be reenergized within 6 minutes from the time the reset button is pressed if the concentration of carbon monoxide surrounding the alarm remains at 70 ppm or greater. • The alarm will remain silent if the CO concentration has decreased below the alarm level of the standard. See WHAT TO DO IF YOUR ALARM SOUNDS section of this manual for important action steps to be taken. • The alarm will continue for as long as the condition exists. The alarm will not permanently end its alarm mode until the concentration of CO has been reduced to a safe level. Espanol Caracteristicas de la alarma de CO (continuacion) ADVERTENCIA Esta alarma esta disenada para detectar el gas monoxido de carbono de cualquier fuente de combustion, NO esta disenada para detectar humo, fuego ni ningun otro tipo de gas. Si suena la sirena de la alarma de CO, no suponga que se trata de una falsa alarma, sino, prestele atencion inmediata. ADVERTENCIA Este producto es para usarse en lugares comunes dentro de viviendas familiares. No esta disenado para medir el cumplimiento con las normas comerciales o industriales de la Administracion de Seguridad y Salud Ocupacional de los Estados Unidos (OSHA). Donde instalar la alarma de CO ! ADVERTENCIA El gas monoxido de carbono puede estar en cualquier parte y en todas partes, pesa lo mismo o es ligeramente mas liviano que el aire y se dispersa uniformemente con el aire de la habitacion. Por consiguiente, instale esta alarma de CO donde el aire circule mejor. NO instale la alarma de CO a un pie 30 cm (1 pie) o menos de la interseccion de la pared con el cielo raso, en la interseccion de dos paredes, ni en otros espacios de “aire muerto”. Ya que la mayoria de las muertes por CO ocurren mientras las familias estan durmiendo, recomendamos que instale, por lo menos, una alarma en los pasadizos de las diferentes areas de dormir y otra alarma en cada uno de los dormitorios o areas de dormir. Tambien recomendamos que instale una alarma en cada una de las areas o habitaciones de los diferentes niveles donde los miembros de la familia estan con frecuencia, asi como en el sotano. Las figuras 1, 2 y 3 muestran las ubicaciones tipicas de las alarmas dentro de la casa. Esta alarma puede compartir el cable de interconexion de las alarmas de humo y calor, PERO esta alarma permanecera en silencio si el humo es detectado por las alarmas interconectadas de humo y calor. Por lo tanto, 5 ! ! How to Operate Your CO Alarm (cont.) Test Your CO Alarm Weekly Momentarily press the TEST/RESET button and note the alarm sound. Also note that the LED indicators flash the proper test sequence as described in HOW TO INSTALL YOUR CO ALARM. If the alarm does not beep after depressing the TEST/RESET button or exhibit the correct LED test sequence, immediately return the CO alarm to Maple Chase for repair or replacement. See the warranty information at the end of this manual. Do not attempt to repair the unit yourself as this may cause damage and will vo...