Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Greenheck Fan, modell Combination Fire Smoke Damper FSD-211

Hersteller: Greenheck Fan
Dateigröße: 569.93 kb
Dateiname: 2581068b-f565-4981-b65f-b2b378085a75.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


AmCA 5.3 Pressure drop Fsd-211 5D 6D Figure 5.3 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) Velocity (fpm) Pressure Drop (in. wg) Velocity (fpm) Pressure Drop (in. wg) Velocity (fpm) Pressure Drop (in. wg) Velocity (fpm) Pressure Drop (in. wg) Velocity (fpm) Pressure Drop (in. wg) 500 0.02 500 0.01 500 0.01 500 0.01 500 0.02 1000 0.09 1000 0.04 1000 0.03 1000 0.04 1000 0.07 1500 0.20 1500 0.09 1500 0.06 1500 0.10 1500 0.16 2000 0.36 2000 0.16 2000 0.11 2000 0.17 2000 0.29 2500 0.56 2500 0.25 2500 0.17 2500 0.27 2500 0.45 3000 0.81 3000 0.35 3000 0.24 3000 0.39 3000 0.64 3500 1.10 3500 0.48 3500 0.33 3500 0.53 3500 0.88 4000 1.44 4000 0.63 4000 0.42 4000 0.70 4000 1.14 Greenheck Fan Corporation certifies that the model FSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. AmCA 5.5 Pressure drop Fsd-211 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) Velocity (fpm) Pressure Drop(in. wg) Velocity (fpm) Pressure Drop(in. wg) Velocity (fpm) Pressure Drop(in. wg) Velocity (fpm) Pressure Drop(in. wg) Velocity (fpm) Pressure Drop(in. wg) 500 0.06 500 0.03 500 0.03 500 0.03 500 0.04 1000 0.22 1000 0.14 1000 0.12 1000 0.13 1000 0.17 1500 0.50 1500 0.31 1500 0.26 1500 0.30 1500 0.38 2000 0.89 2000 0.54 2000 0.46 2000 0.53 2000 0.67 2500 1.39 2500 0.85 2500 0.73 2500 0.83 2500 1.04 3000 2.00 3000 1.22 3000 1.05 3000 1.19 3000 1.50 3500 2.72 3500 1.66 3500 1.42 3500 1.62 3500 2.05 4000 3.55 4000 2.17 4000 1.86 4000 2.11 4000 2.67 Greenheck Fan Corporation certifies that the model FSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. Application data damper sleeve dimensional data The drawings below and corresponding table show the position of the FSD-211 damper when mounted in a factory sleeve. The standard mounting locations provide enough space for the mounting of actuators, controls and allow space for installation of retaining angles and duct connections. The standard location of a damper mounted in a factory sleeve ("A" dimension) is shown below. The damper can be positioned at other locations within a range of 6 in. (152mm) to 12 in. (305mm) for the "A" dimension. 6 in. LH RH 11/2 in. max. 53/8 in. V aries 33/4 in. *With the exception of dampers 10 in. high (254mm) or less. NOTE: Entire damper frame is not required to be installed within the wall. The damper blades, when closed should be contained within the wall. Right hand drive is show n A 5 in. Left hand drive available upon request Sleeve Length in. (mm) "A" Dimension Standard Maximum All Dampers* 7 3/16 (183) 12 (305) When H is 11 in. (279mm) or less with OCI, RRL, or TOR 12 (305) 12 (305) T* S B* Actuators and Accessories space envelopes Externally mounted actuators always require space outside of the damper sleeve. The “S” dimension illustrates the clearance required for various available actuators. On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the sleeve. “B” and “T” dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper sleeve is limited, each damper size should be individually evaluated. Actuator Type/Model B* T* SWith RRL, RRL/OCI, or TOR With RRL, RRL/OCI, or TOR 120 Volt AC ML-4XXX Series Honeywell 5. in. (133mm) . in.(19mm) 6 in. (152mm) MS-4XXX Series Honeywell 6 in. (152mm) 3/8 in. (10mm) 6 in. (152mm) MS-4120 Series Honeywell 6 in. (152mm) 3/8 in. (10mm) 6 in. (152mm) 24 Volt AC ML-8XXX Series Honeywell 5. in. (133mm) . in.(19mm) 6 in. (152mm) MS-8XXX Series Honeywell 6 in. (152mm) 6 in. (152mm) 6 in. (152mm) MS-8120 Series Honeywell 6 in. (152mm) 6 in. (152mm) 6 in. (152mm) Pneumatic (25 psi min.) 331-4551 Powers 1 in. (25mm) 6. in. (159mm) 6. in. (165mm) 331-2976 Powers 2 3/8 in. (60mm) 12 1/8 in. (308mm) 9. in. (235mm) MK2-7121 Invensys 3 3/4 in. (95mm) 16. in. (419mm) 10 in. (254mm) * For dampers 18 in. (457mm) or more in height these dimensions are 0 in. . damper sizing Information Dampers larger than maximum single section size are supplied as a factory assembly of two or more sections of equal size. The following figures show maximum damper section size and assembly configurations for multi-secti...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien