The test/reset button has four purposes. It tests the unit’s electronics, resets the CO alarm, activates the HUSH feature, and activates the Peak Level Memory Feature. After installation, TEST THE UNIT’S ELECTRONICS by pressing and releasing the test/reset button. A series of beeps will sound, followed by the message “Fire! Fire!” then another two series of beeps and the message “WARNING! CARBON MONOXIDE!” followed by 4 additional short beeps. Weekly testing is required! If at anytime it does not perform as described, verify power is connected correctly and that the battery doesn’t need replacing. Clean dust and other buildup off the unit. If it still doesn’t operate properly call the Consumer Hotline at 1 (800) 880 6788. Interconnect Feature Your Combination Smoke/CO Alarm can be interconnected to other multiple station Kidde, Nighthawk, Kidde/Fyrnetics, and Kidde/FireX products: • When compatible smoke alarms and heat alarms are interconnected to your Smoke/CO Alarm, they will only respond to a smoke related event. • When mixing compatible models with battery backup with models without battery backup, be advised that the models without battery backup will not respond during an AC power failure. • This unit is only approved to interconnect with other Kidde/Nighthawk products. It is NOT approved to interconnect with any other brand of detection product. Operating and Installation Instructions Operating and Installation Instructions • This alarm is interconnect compatible with the following alarms and accessories: – Smoke alarms: 1235, 1275, 1276, 1285, 1296, i12020, i12040, i12060, i12080, PE120, PI2000, KN-COSM-IB, KN-COSM-I, KN-SMFM-i and RF-SM-ACDC. Kidde/Firex 4618, 4518, 4480, 460, 484, and P4580 – Heat alarm: HD135°F – CO alarms: KN-COB-IC, KN-COP-IC, KN-COPF-i – Relay modules: 120X, SM120X, CO120X – Strobe Light: SL177i See User’s Guides for specific application information. • For more information about compatible interconnect units and their functionality in an interconnect system, visit our web site at HUSH® Control Feature The HUSH® feature has the capability of temporarily desensitizing the smoke alarm circuit for approximately 10 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm. You can put your Smoke/CO Alarm in HUSH® mode by pushing the test/reset button. If the smoke is not too dense, the alarm will silence immediately, the unit will verbally announce “HUSH MODE ACTIVATED”, and the green LED will flash every 2 seconds for approximately 10 minutes. This indicates that the smoke alarm is in a temporarily desensitized condition. Your Smoke/CO Alarm will automatically reset after approximately 10 minutes. When the unit returns to normal operation after being in HUSH® mode, it will verbally announce “HUSH MODE CANCELLED”, and sound the alarm if smoke is still present. The HUSH® feature can be used repeatedly until the air has been cleared of the condition causing the alarm. While the unit is in HUSH® mode, pushing the test/reset button on the alarm will also end the HUSH® period. Operating Instructions Operating Instructions NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH® CONTROL FEATURE AND SOUND A CONTINUOUS ALARM. CAUTION: BEFORE USING THE ALARM HUSH® FEATURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS. Reset Feature If the Smoke/CO Alarm is sounding a CO alarm, pressing the test/reset button will initiate a test/reset. If the CO condition that caused the alert continues, the alarm will reactivate. Low Battery HUSH® CONTROL When the battery needs to be replaced, the unit will produce a low battery “chirp” once per minute. The Low Battery HUSH® feature allows you to press the button on the alarm producing the warning and disable the “chirp” for a random period of up to 12 hours. This gives you a chance to replace the battery at a more convenient time without sacrificing your safety by disconnecting the alarm from power. During this Low Battery HUSH® period, your alarm is performing normally and is not desensitized. Alarm/Peak Level Memory If the green LED is blinking once every 16 seconds, the unit has detected a hazardous condition. If the unit has detected a CO level of 100 PPM or greater, pushing the Test/Reset button will result in a voice message “Caution, carbon monoxide previously detected”. Peak level also happens if the unit detects smoke and then comes out of alarm. However, there is no voice message if the unit is in peak level due to smoke. When the Test/Reset button is pushed, the unit will produce three rapid beeps. Pushing the test/reset button resets the memory. It’s also reset when the power is removed. LED Indicator Operation Red LED The red LED will flash in conjunction with the alarm sounder. Therefore, the red LED will flash during a smoke Operating Instructions Operating Instructions alarm, a CO alarm, a low battery mode chirp and a unit error mode chirp. Green LED Th...

Dieses Handbuch ist für folgende Modelle:
Alarm - KN-COPE-I (207.8 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien