Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Kidde, modell 0914

Hersteller: Kidde
Dateigröße: 118.55 kb
Dateiname: fa676014-fd23-4fe7-bec2-01085bb2ec47.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


It is an important part of your family’s home safety plan. You can trust this product to provide the highest quality safety protection. We know you expect nothing less when the lives of your family are at stake. For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked. Smoke Alarm Model Number (located on back of alarm): Date Code (located on back of alarm). The National Fire Protetcion Association (NFPA) and the manufacturer recommends replacing this alarm ten years from the date code: Date of Purchase: Where Purchased: LISTED This product is designed to detect products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioactive material. Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any regulatory requirements. WARNING! ALARM WILL NOT ATTACH TO MOUNTING PLATE UNLESS BATTERY IS PRESENT. REMOVAL OF BATTERY WILL RENDER THE SMOKE ALARM INOPERATIVE. IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE. CONTENTS OF THIS MANUAL 1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 -- LOCATIONS TO AVOID 3 -- INSTALLATION INSTRUCTIONS 4 -- OPERATION AND TESTING 5 -- NUISANCE ALARMS 6 -- MAINTENANCE 7 -- LIMITATIONS OF SMOKE ALARMS 8 -- GOOD SAFETY HABITS 9 -- NRC INFORMATION 10 -- NFPA PROTECTION STANDARD 72 11 -- CALIFORNIA STATE FIRE MARSHALL REQUIRED INFORMATION 12 -- SERVICE AND WARRANTY This smoke alarm uses an extremely small amount of radioactive element in the ionization chamber (see Section 9). Do not try to repair the smoke alarm yourself. Refer to the instructions in Section 12 for service. 1. RECOMMENDED LOCATIONS FOR ALARMS • Locate the first alarm in the immediate area of the bedrooms. Try to protect the exit path as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms in each sleeping area. • Locate additional alarms to protect any stairway as stairways act like chimneys for smoke and heat. • Locate at least one alarm on every floor level. • Locate an alarm in every bedroom. • Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers). • Locate an alarm in every room where someone sleeps with the door closed. The closed door may prevent the alarm from waking the sleeper. •Smoke, heat, and combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction. • For mobile home installation, select locations carefully to avoid thermal barriers that may form at the ceiling. For more details, see MOBILE HOME INSTALLATION below. •When mounting an alarm on the ceiling, locate it at a minimum of 4” (10 cm) from the side wall. (see Diagram A). •When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling. (see Diagram A). • Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 feet (9.1 m) long. •Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft (0.9m)of the highest point (measured horizontally). NFPA 72 states: “Smoke alarms in rooms with ceiling slopes greater than 1 foot in 8 feet (.3m in 2.4m) horizontally shall be located on the high side of the room.” NFPA 72 states: “A row of alarms shall be spaced and located within 3 ft (0.9 m) of the peak of the ceiling measured horizontally” (see diagram ”C”). DIAGRAM “A” . Smoke Alarms for Minimum Protection .. Smoke Alarms for Additional Protection ^^ Ionization Type Smoke Alarms with “Hush” Control or Photoelectric Type DIAGRAM “B” ANYWHERE IN THIS AREA 3 ft 3 ft (0.9m) (0.9m) HORIZONTAL DISTANCE FROM PEAK DIAGRAM “C” MOBILE HOME INSTALLATION Mobile homes built in the past five to seven years have been designed to be energy efficient. Install smoke alarms as recommended above (refer to RECOMMENDED LOCATIONS and Diagram A). In mobile homes that are not well insulated compared to present standards, extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof. This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling. In such units, install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling (see Diagram A). If you are not sure about the insulation in your mobile home, or if you notice that the outer walls and ceiling are either hot or cold, install the alarm on an inside wall. For minimum protection, install at least one alarm close to t...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien