c IS Optical Smoke Detector 2251EIS The addressable Intrinsically Safe Optical Smoke Detector 2251EIS (fig. A) uses the scattered light principle and was developed for the detection of smoke particles in hazardous areas. The modern design of the sensing chamber allows to reliably evaluate the characteristics of fire. The proven ADM loop technology with System Sensor/200 protocol establishes a permanent communication between the fire detection control panel and the detector. That ensures a periodical function testing of the detector. In the control panel all types of fires are detected by continuously comparing fire patterns. Intelligent evaluation algorithms use the current condition of the sensing chamber to predict the likely time of the next maintenance. Thus the alarm threshold is automatically adjusted within the permissible range, depending on the contamination. With that, the constant response sensitivity of the detector is ensured for a long time. The two LEDs with 360° visibility indicate the activated condition of the detector. The detector address is selected with two decadic rotary switches, thus allowing to change the detector without additional tools. A detector function test can be conveniently conducted using a magnet or test gas. The detector can be protected against theft. Specifications Ignition protection intrinsically safe Ex classification EEx ia IIB T5 Operating voltage Supply through loop voltage Current consumption at 24V 330|jA Ambient temperature -25°C to +70°C Relative humidity 5 - 95% (no condensation) Dimensions 0 x H 103 x 43 (mm) Colour cream Weight 110g Approval BASEEFA03ATEX0157X LPCB 199m Order number 241025 Order name IS Optical Smoke Detector/Anal./200/SS 2251EIS £ № a vfy Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52H4-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED Ex-Sys200_DBL_LST_EN_0804.PDF • PAGE 1 Safety Barrier Y72221 The Safety Barrier Y72221 (fig. B) is used for intrinsi- detectors in hazardous areas. Due to the galvanic isola-cally safe electric circuits. The built-in zener barrier and tion, the earth leakage monitoring can remain activated the safe galvanic isolation allow the connecton of fire in the fire detection control panel. Specifications Ignition protection intrinsically safe Ex classification EEx ia IIC T5 Operating voltage Supply through the detector line voltage Ambient temperature -20°C to +60°C Dimensions W x H x D 20 x 110 x 107.5 (mm) Mounting TS35 DIN rail Colour green Weight 100g Approval BASEEFA Nr.: BAS00ATEX7087 Order number 228006 Order name Safety Barrier/Anal./200/SS Y72221 Protocol Interface IST200 The Protocol Interface IST200 (fig. C) serves for the design of an intrinsically safe electric circuit in ADM loop technology. It allows the bidirectional data traffic between fire detection control panel and fire detectors in hazardous areas via an ADM loop with System Sen- sor/200 protocol. The interface is always used together with the Safety Barrier Y72221. The Surface Mounting Box SMB500 is required for mounting the protocol interface. Specifications Ignition protection intrinsically safe Operating voltage Supply through loop voltage Current consumption at 24V 14mA Ambient temperature 0°C to +60°C Relative humidity 5 - 95% (no condensation) Dimensions W x H x D (without attaching sheet) 70 x 70 x 32 (mm) Weight 155g Order number 228007 Order name Protocol Interface/Anal./200/SS IST200 Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52H4-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED Ex-Sys200_DBL_LST_EN_0804.PDF • PAGE 2...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien