Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Bosch, modell S66M63N1EU/03

Hersteller: Bosch
Dateigröße: 1.19 mb
Dateiname:

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten


Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Install the appliance in the correct sequence: – Checking appliance on delivery – Installing the appliance – Waste water connection – Fresh water connection – Electrical connection Safety instructions – Install and connect the appliance according to the installation and assembly instructions. – Prior to installation, disconnect the dishwasher from the power supply. – Ensure that the protective conductor system of the domestic supply has been correctly installed. – The electrical connection conditions must correspond with the specifications on the dishwasher rating plate 9". – If the power cord of this appliance is damaged, it must be replaced with a particular power cord. To prevent injury, the power cord may be replaced by customer service only. – If the dishwasher is installed in a high- sided unit, the unit must be secured properly. – Do not install the appliance near heat sources (radiators, heat storage tanks, cookers or other appliances which generate much heat) and install it under a hob only in consideration of the stipulated safety clearances. – After installing the appliance, ensure that the plug is easily accessible. en – Some models: The plastic housing on the water connection contains an electric valve, the connecting cables are in the supply hose. Do not cut through this hose, do not immerse the plastic housing in water. Delivery Your dishwasher has been checked thoroughly in the factory to ensure that it is in working order. This may cause small water stains. These will disappear after the first wash cycle. Technical specifications Weight: max. 27 kg Voltage: 220–240 V, 50 Hz or 60 Hz Connected load: 2.0–2.4 kW Fuse: 10/16 A Water pressure: at least 0.05 MPa (0.5 bar), maximum 1 MPa (10 bar). At a higher water pressure: connect pressure-reducing valve ahead. Inlet rate: minimum 10 litres/minute Water temperature: cold water; hot water max. temperature 60 °C. Installation The required installation dimensions can be found in the installation instructions. Level the appliance. Ensure that the appliance is situated securely on the floor. – The appliance can easily be installed in a fitted kitchen between wooden and plastic walls. If the plug is not freely accessible, an allpole disconnector with a contact opening of at least 3 mm must be fitted on the installation side to satisfy the relevant safety instructions. Waste-water connection – The required work sequence can be found in the installation instructions. If required, fit a siphon with an drainage connection. – Connect the waste-water hose to the drainage connection of the siphon with the enclosed parts. Ensure that the drainage hose is not kinked, crushed or twisted and that there is no cover plate in the drainage to prevent the waste water from flowing out! Fresh water connection – Connect the fresh-water connection to the tap according to the installation instructions with the enclosed parts. Ensure that the fresh-water connection is not kinked, crushed or twisted. – When replacing the appliance, always use a new water supply hose. Water pressure: at least 0.05 MPa (0.5 bar), maximum 1 MPa (10 bar). At a higher water pressure: connect pressure-reducing valve ahead. Inlet rate: minimum 10 litres/minute Water temperature: cold water; hot water max. temperature 60 °C. Warm water connection * * depending on model The dishwasher can be connected to cold or hot water up to max. 60 °C. Connection to hot water is recommended if the hot water can be supplied by energetically favourable means and from a suitable installation, e.g. solar heating system with circulation line. This will save energy and time. The hot water setting ‘:‹‚ allows you to adjust your appliance optimally to operation with hot water. en It is recommended to have a water temperature (temperature of the incoming water) of at least 40 °C and no more than 60 °C. It is not recommended to connect the appliance to hot water if the water is supplied from an electric boiler. Setting hot water: – Close the door. – Switch on ON/OFF switch (. – Hold down programme button # and press START button ` until •:‹... is indicated on the digital display. – Release both buttons. The LED for button # flashes and the digital display )" displays the factory setting •:‹…. – Press programme button # until the factory set value ‘:‹‹ is indicated on the digital display )". To change the setting: – By pressing the 3 button, you can switch the hot water setting off ‘:‹‹ or on ‘:‹‚. – Press START button `. The set value is saved. Electrical connection – Connect the appliance to an alternating current only, ranging from 220 V to 240 V and 50 Hz or 60 Hz via a correctly installed socket with protective earth conductor. See rating plate for required fusing 9". – The socket must be near the appliance and freely accessible following installation. – The connection may be modified by technicians only. – A power cord extension may be purchased from customer service only. – Use only a residual current operated circu...

Dieses Handbuch ist für folgende Modelle:
Geräte - S66M63N1EU/05 (1.19 mb)
Geräte - S66M63N1EU/07 (1.19 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien