|
Anleitung Zusammenfassung
Checking appliance on delivery 2. Installing the appliance 3. Waste water connection 4. Fresh water connection 5. Electrical connection Product package If you have any complaints, contact the dealer where you purchased the appliance or our customer service. . Dishwasher . Instructions for use . Installation instructions . Warranty* . Installation materials . Steam guard plate* . Rubber apron* . Power cord * depending on model Safety instructions Please follow the safety instructions under “Installation”. Delivery Your dishwasher has been checked thoroughly in the factory to ensure that it is in working order. This may cause small water stains. These will disappear after the first wash cycle. Technical specifications Weight: max. 60 kg Voltage: 220–240 V, 50 Hz or 60 Hz Connected load: 2.0–2.4 kW Fuse: 10/16 A (UK 13A) Power input: switched off 0.1 W not switched off 0.1 W Water pressure: at least 0.05 MPa (0.5 bar), maximum 1 MPa (10 bar). At a higher water pressure: connect pressure-reducing valve ahead. Inlet rate: minimum 10 litres/minute Water temperature: Preferably cold water; if hot water, depending on type of water inlet hose, max. temp. 60 °C (see Fresh water connection). Installation and connection en Installation The required installation dimensions can be found in the installation instructions. Level the appliance with the aid of the height-adjustable feet. Ensure that the appliance is situated securely on the floor. . A built-under or integrated appliance which is installed subsequently as a free-standing appliance must be secured to prevent it from overturning, e.g. by screwing it to the wall or by installing it under a continuous worktop which is screwed to adjacent cupboards. . The appliance can easily be installed in a fitted kitchen between wooden and plastic walls. Waste-water connection 1. The required work sequence can be found in the installation instructions. If required, fit a siphon with an drainage connection. 2. Connect the waste-water hose to the drainage connection of the siphon with the enclosed parts. Ensure that the drainage hose is not kinked, crushed or twisted and that there is no cover plate in the drainage to prevent the waste water from flowing out! Fresh water connection 1. Connect the fresh-water connection to the tap according to the installation instructions with the enclosed parts. Ensure that the fresh-water connection is not kinked, crushed or twisted. 2. When replacing the appliance, always use a new water supply hose. en Installation and connection Water pressure: at least 0.05 MPa (0.5 bar), maximum 1 MPa (10 bar). At a higher water pressure: connect pressure-reducing valve ahead. Inlet rate: minimum 10 litres/minute Water temperature: Note printing on the water inlet hose! If models are marked with 25°, the water temperature may be max. 25 °C (cold water). For all other models: cold water preferred; hot water max. temperature 60 °C. Warm water connection * depending on model The dishwasher can be connected to cold or hot water up to max. 60 °C. Connection to hot water is recommended if the hot water can be supplied by energetically favourable means and from a suitable installation, e. g. solar heating system with circulation line. This will save energy and time. The hot water setting ‘:‹‚ allows you to adjust your appliance optimally to operation with hot water. It is recommended to have a water temperature (temperature of the incoming water) of at least 40 °C and no more than 60 °C. It is not recommended to connect the appliance to hot water if the water is supplied from an electric boiler. Setting hot water: 1. Close the door. 2. Switch on ON/OFF switch (. 3. Press and hold down the START button @. 4. Rotate programme selector 8 until ‘:‹‚ is indicated on the digital display H. 5. Release button. The factory-set value ‘:‹‹ is lit on the digital display H. To change the setting: 1. By rotating the programme selector 8, you can switch the hot water setting off ‘:‹‹ or on ‘:‹‚. 2. Press START button @. The set value is saved. Installation and connection en Electrical connection . Connect the appliance to an alternating current only, ranging from 220 V to 240 V and 50 Hz or 60 Hz via a correctly installed socket with protective earth conductor. See rating plate for required fusing 92. . The socket must be near the appliance and freely accessible following installation. If the plug is not freely accessible, an allpole disconnector with a contact opening of at least 3 mm must be fitted on the installation side to satisfy the relevant safety instructions. . The connection may be modified by technicians only. . A power cord extension may be purchased from customer service only. . Use only a residual current operated circuit-breaker which features the symbol ‚. Only this extension guarantees compliance with the currently valid regulations. . The appliance features a water damage protection system. Please note the system will not function unless the power supply is c...
Dieses Handbuch ist für folgende Modelle:Geräte - SN24D230TR/13 (1.8 mb)
Geräte - SN24D230TR/18 (1.8 mb)
Geräte - SN24D830TR/09 (1.8 mb)
Geräte - SN24D830TR/13 (1.8 mb)