Anleitung Zusammenfassung
2. Start the washer with rocker switch located on the front of the machine. Take a sample from the final rinse spray tube to check sanitizer level. 3. To increase the volume of sanitizer, turn the adjustment screw clockwise. 4. To decrease the volume of sanitizer, turn the adjustment screw counter-clockwise. NOTE: If Iodopher is being used as a sanitizer, it is not necessary to use a separate rinse agent. To turn rinse agent injector “OFF” in this case, turn the adjustment screw counter-clockwise until the pump stops turning. NOTE: If a sodium Hypochlorite (Chlorine) based sanitizer at a minimum concentration of 50PPM in the final rinse is used, use chlorine test papers to verify and monitor the 50PPM chlorine level. OPERATION OPERATION (Cont’d) To Adjust Rinse Agent Injector: 1. When a new rinse agent container is installed, push the prime button in and hold until the rinse injector feed tube is full. 2. Start the washer. Take a sample from the final rinse spray tubes. 3. To increase the volume of rinse agent, turn the adjustment screw clockwise. 4. To decrease the volume of rinse agent, turn the adjustment screw counter-clockwise. NOTE: To meet the requirements of N.S.F. standards, Iodophor in a concentration of 12.5 ppm or chlorine at 50 ppm must be used in the final rinse. OPERATION OPERATION (Cont’d) RINSE 1) WASH WATER TANK2) STAND PIPE3) WASH RETURN SCREEN4) DRAIN PAN5) DRAIN SCREEN6) WASH PUMP 8) CHEMICAL INJECTOR9) INJECTION FITTING10) WATER INLET VALVES11) MIXING VALVE12) VACUUM BREAKERFLOW WASH12 10 1011 89 7 3 1 2 4 5 RINSE SAN DET7) MAIN TANK STANDPIPE HOTCOLDWATER IN WATER IN TO DRAIN 6 Figure 4 — Plumbing Diagram MAINTENANCE MAINTENANCE CLEANING Daily Cleaning Instructions 1. Remove the drain tray/waste collector (if installed), from the front of your glasswasher. 2. Turn glasswasher off by flipping the toggle switch located on the wash tank to the “OFF” position. 3. Remove right and left hand trays and splash curtain. Wash them with hot soapy water, rinse thoroughly, then dry. 4. Remove the conveyor as follows: Remove cylinder in center of conveyor, flip shut-off rod to the side, lift conveyor from center and pull out. 5. Remove lower wash and rinse arms. Clean wash and rinse areas with hot soapy water. Rinse thoroughly, then dry. 6. Replace lower wash and rinse arms (they only fit one way). Replace conveyor as follows: With back end of conveyor raised, mesh drive gear with side of conveyor, pull conveyor towards you until center of conveyor drops onto pivot. Replace cylinder in center of conveyor, flip shut-off bar back to normal position. Replace left hand tray ensuring shut-off arm rests within the retainer, then replace right hand tray. Replace curtain. 7. Remove and clean upper and lower wash tank screens. 8. Remove stand pipe from the detergent tank, wash down the interior of the detergent tank. Replace stand pipe and upper and lower wash tank screens. NOTE: Do not leave water in tank overnight!!! 9. Replace drain tray/waste collector (if installed) making sure hose is connected. 10. Ensure there is product in the detergent, sanitizer and rinse agent containers. Close door. Weekly Cleaning Instructions 1. Remove upper and lower wash and rinse arms from the manifold and clean spray tubes with reamer, tube brush, and tube scraper provided. 2. Remove detergent, sanitizer, and rinse agent feed lines from containers and place them in a container of hot water. Hold prime buttons in until the feed lines have been thoroughly flushed. Replace the feed lines to their proper container and prime product through lines. TROUBLESHOOTING TROUBLESHOOTING CONDITION CAUSE SOLUTION Conveyor does not turn No power.............................................Check fuse panel Turn power switch on Drive motor burnt out .........................Replace Obstruction in wash or rinse ..............Remove obstruction Micro-switch on switch support..........Adjust or replace bracket faulty or not making contact Conveyor not in position.....................Position properly Excessive overspray Splash curtain not in position ............Install or adjust from hood section Washer running without any...............Keep conveyor loaded with glasses glasses on conveyor Spray tubes fallen off hub...................Ensure spray tube is pushed firmly on to hub connection Spray tubes plugged............................Clear and clean with reamer, scraper, and brush Lack of pressure at wash No water in detergent tank..................Ensure water supply is on spray tubes Ensure detergent tank stand pipe is in postion Ensure the tank fill switch is in “ON-FILL” position and that tank fills with water Ensure the float switch is activated by the float cam Ensure the tank fill solenoid valve is operational Obstruction in wash arm .....................Clear obstruction Pump not operating .............................Check power supply to machine Check pump capacitor Replace pump if required Pump operating but no pressure.............
Dieses Handbuch ist für folgende Modelle:Geräte - DF-M6 (307.16 kb)
Geräte - DF2-M6 (307.16 kb)