Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Jackson, modell AJ-100CS

Hersteller: Jackson
Dateigröße: 9.55 mb
Dateiname:

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


Prewash Plan View Section with Cold Water Thermostat 163 4 [425mm] 161 4 [415mm] F G 3/4" [19 mm] Table Turndown Flange 3/4" Max Rack Rail Height 21" [533 mm] Above Dishtable 1/4" [6mm] - 5/16" [8mm] Rack Rail Tub Table Use Silicone Sealer Between Table and Lip of Machine to Prevent Leakage Recommended Table Fabrication Note: Tub Will Accept a Table Flange Up to 24 7/8" [632 mm] 86 [2184mm] 661 2 [1692mm] 651 2 [1666mm] 1 [25mm] 601 4 [1530mm] 651 2 [1665mm] 101 4 [260mm] SECTION 1: SPECIFICATION INFORMATION AJ-86 ELECTRIC - LEFT TO RIGHT 11 AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: 09-29-2007 Right Side 34 [864mm] 21 [533mm] 25 [635mm] 12 [307mm] 25 [635mm] Table to Table Overall Dish Clearance B Right to Left Drive Unit Left Side 1 2 [15mm] 84 [2134mm] With Doors Open Rear of Machine Legend A - Machine water inlet 3/4" NPT, 180°F Hi-temp, 140°F Low-temp minimum B - Electrical connection C - Drain connection 1-1/2" NPT D - Vent collar - Optional E - Vent cowl standard F - Prewash water inlet 3/4" NPT 110°F-140°F G - Cold water thermostat plumbing connection 3/4" NPT - Optional Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with Cover Plate. Floor Sink Or Drain With 3" (76 mm) Minimum Drain Line 86 [2182mm] 94 [2385mm] 102 [2588mm] 651 2 [1665mm] 81 2 C [218mm] B 64 [1626mm] Base Unit 22 [557mm] Prewash Prewash Plan View Section with Cold Water Thermostat 1634 [425mm] 161 4 [415mm] F 3/4" [19 mm] G Table Turndown Flange 3/4" Max Rack Rail Height 21" [533 mm] Above Dishtable 1/4" [6mm] - 5/16" [8mm] Rack Rail Tub Table Use Silicone Sealer Between Table and Lip of Machine to Prevent Leakage Recommended Table Fabrication Note: Tub Will Accept a Table Flange Up to 24 7/8" [632 mm] 25 [635mm] 4 1/2 [114mm] 81 4 [210mm] 21 [533mm] Drive Unit 601 4 [1530mm] 621 2 [1590mm] 29 [737mm] 10 [254mm] 6 [152mm] 4 [102mm] 7 [178mm] D E 8 [203mm] F 24 [610mm] G 231 2 [599mm] 101 4 [261mm] 47 [1194mm] A 533 4 [1365mm] B C 43 [1092mm] 751 2 [1919mm] 661 2 [1692mm] 3 [79mm] A G 1 [25mm] F Front Side SECTION 1: SPECIFICATION INFORMATION AJ-86 ELECTRIC - RIGHT TO LEFT 12 AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: 09-29-2007 51 2 [140mm] 41 [1040mm] 203 4 [527mm] 83 4 [222mm] 113 4 [298mm] 143 4 [375mm] 6 [154mm] 30 [763mm] 14 [357mm] 71 4 [185mm] 11 4 [35mm] 323 4 [833mm] 94 [2388mm] Drive Unit 751 2 [1918mm] 21 2 [61mm] 621 2 [1590mm] 34 [864mm] 29 [737mm] 81 2 [218mm] 21 [533mm] 25 [635mm] 12 [307mm] 1 [25mm] 25 [635mm] 10 [254mm] C B A M 4 [102mm] 24 [609mm] 453 4 [1161mm] L A 102 [2591mm] 231 2 [598mm] 6 [152mm] 7 [178mm] D E B 331 2 [851mm] 8 [206mm] Drive Unit 1 2 [15mm] 84 [2134mm] A L M B Dish Clearance With Doors Open Rear of Machine 14 [356mm] Minimum 10" High Table Backsplash Scrap Trough 6 [152mm] Table to Table Overall 36 [914mm] 311 4 [795mm] 61 2 [165mm] 261 2 [673mm] 6 [152mm] Left Side Front View Right Side C Floor Sink Or Drain With 3" (76 mm) Minimum Drain Line 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with Cover Plate. Minimum Scrap Trough 14 [355mm] 25 [635mm] 21 [533mm] 8 [203mm] 22 [559mm] 64 [1626mm] Prewash Base Unit F Left to Right Legend A - Machine water inlet 3/4" NPT, 180°F Hi-temp,140°F Low-temp minimum B - Electrical connection C - Drain connection 1-1/2" NPT D - Vent collar - Optional E - Vent cowl standard F - 3/4" NPT 180°F Water Inlet for wash tank fill, final rinse, & tank heating. From gas booster heater. Interconnecting hose provided by manufacturer. G - 3/4" NPT 140°F Water inlet for gas booster heater. H - 3/4" NPT 180°F Water Outlet connection to line on dishmachine. Connection hose provided by manufacturer. J - 3/4" NPT Gas Connection K - 4" OD Vent pipe connection. Flue to be installed to meet local codes by installing contractor. L - Prewash water inlet 3/4" NPT 110°F-140°F M - Cold water thermostat plumbing connection 3/4" NPT - Optional Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 86 [2184mm] H G J K H G J K 661 2 [1692mm] 651 2 [1666mm] Prewash Plan View Section with Cold Water Thermostat 163 4 [425mm] 161 4 [415mm] L M 3/4" [19 mm] Table Turndown Flange 3/4" Max Rack Rail Height 21" [533 mm] Above Dishtable 1/4" [6mm] - 5/16" [8mm] Rack Rail Tub Table Use Silicone Sealer Between Table and Lip of Machine to Prevent Leakage Recommended Table Fabrication Note: Tub Will Accept a Table Flange Up to 24 7/8" [632 mm] SECTION 1: SPECIFICATION INFORMATION AJ-86 GAS - LEFT TO RIGHT 13 AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: 09-29-2007 Drive Unit 601 4 [1530mm] 621 2 [1590mm] 29 [737mm] 10 [254mm] 6 [152mm] 4 [102mm] 7 [178mm] D E 8 [203mm] L 24 [610mm] M 231 2 [599mm] 101 4 [261mm] 47 [1194mm] A 5334 [1365mm] B C 751 43 [1092mm] 2 [1919mm] 6 [155mm] 36 [914mm] 311 4 [797mm] 61 2 ...

Dieses Handbuch ist für folgende Modelle:
Geräte - AJ-100CE (9.55 mb)
Geräte - AJ-100CGP (9.55 mb)
Geräte - AJ-64CE (9.55 mb)
Geräte - AJ-64CS (9.55 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien