Anleitung Watlow Electric, modell 35
Hersteller: Watlow Electric Dateigröße: 994.05 kb Dateiname: series_35_eng.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
IS SEC CYCLE TIME C = TIME PROPORTIONING 15°F BAND. 9 SEC CYCLE TIME D = TIME PROPORTIONING _25“F BAND. 5 SEC. CYCLE TIME OUTPUT LD MD KO A = 35A SPST 0 = 60A SPST G = 25A SPST B = 35A 2PST E = 60A 2PST H = 25A 2PST C = 35A 3PST F = 60A 3PST J = 25A 3PST UNE VOLTAGE 115 VAC 230VÄCT CONNECTIONS I - QUICK CONNECTS 2 = BARRIER STRIP SEÎPOT ASSEMBLY ~ i - INTFGftAL 2 = REMOTE ♦ SENSOR RANGE NO 600 = 50 TO 500"F 10 TO 260°C __TYPE J TC 601 = 50 TO IOOO”F 10 TO 538“C TYPE J T£_ 612 = 100 TO 2000'F 50 TO 1050‘C TYPE K TC __ RANG 60 T'êo Mounting Control with Relay 1. Look at the 4th digit of the model number on your unit. Compare the 4th digit with the Model Number Information chart here. Then find the correct mounting diagram at the right to mount your unit. Notice that the mounting diagrams on this page combine details of the similar 35 Amp (LD) and 60 Amp (MD) relays. Diagrams on the back page of this literature show mounting for 25 Amp (KD) Series 35’s. 2. Mark and drill the 0.188 inch mounting holes for your Series 35. Note: On 35 and 60 Amp Series 35’s, maintain 0.50 inch clearance from the lower relay contact to the bottom of an enclosure. On 25 Amp relay Series 35’s, maintain 0.50 inch clearance from the centerline of the lower mounting holes to the bottom of an enclosure. 3. Mount the Series 35 with 10-32 screws. 4. Wire your unit according to the wiring diagram adjacent to the mounting diagram. Remote Set Pot 1. Refer to the Remote Set Pot Mounting Dimensions diagram. 2. Drill a 0.390" diameter hole for the set pot shaft. 3. Drill a 0.140" tab hole to the left of the shaft hole according to the diagram. 4. Drill four 0.96" holes for the corners of the dial scale using the diagram dimensions. 5. Loosen the two set screws on the set pot knob and remove the control knob with its clear plastic shield. Remove the nut and washer from the set pot shaft. 6. Insert the set pot shaft through its hole from the rear placing the aligning tab in its hole. 7. Place the dial scale on the set pot shaft and anchor it with four 4-40 self-tapping screws. 8. Secure the pot shaft with the washer and dial scale nut. 9. Turn the pot shaft to the maximum counter clockwise position. Place the knob on the shaft. 10. Align the indicator mark on the clear plastic shield with the mechanical zero marker on the dial scale. Tighten the two control knob set screws. Mounting NOTE: Control mounting is identical for both integral and remote set pot versions. 1 Pole 35 I 60 Amp Relay Dimensions iiDD-DDDD-DDDD A 1 B 1 C D 1 E 1 F A DIM. 4.55 5.00 B DIM. .90 .744 .750 1.07 .911 .917 NOTE: All dimensions in inches. Series 35 35160 Amp Outputs IQTE SETPOT FOR RANGE ÿ' QUICK CONNECT BARRIER STRIP A006-0428 AÔ06-0430 A006-0429 A006-043I A006-0452 N A Series 35 ■ 25 Amp Output T Mounting NOTE: Control mounting is identical for both integral and remote set pot versions. 1 Pole 2 Pole - 3.000 --3.2I5 - fMh = -tu --3.0I -3.171 - - 3 Pole M3 HtO - 4.565- - 4.5I5 - Wiring NOTE: Themocouple, Relay Terminal and Line Voltage wiring are identical for both integral and remote set pot units. On remote set pot units wire the set pot according to the diagram. TJCRMOCOUPLE Bulletin 352 20MDA384 Now Watlow Offers You the “Advantage”.. A Unique Combination of a Low Cost, High Capability Temperature Control and a Power Switching Module We call our new Series 35 switching control module the "Advantage” because it gives you what you’ve never had before in low cost, temperature control ... a high performance thermocouple temperature control and a reliable mercury relay combined in a single, inexpensive, simple to use package. You Can Enjoy the “Advantages” of • Thermocouple sensor included • Precise control to adjustable set point • High ampere switching (35 & 60 amp) • Solid state electronics • Exceptional reliability • Hermetically-sealed switch • Extended, trouble-free life • 1, 2 & 3 pole models • Wider temperature ranges • Ease of installation • Quiet operation • Off-the-shelf availability • Available metal enclosure • Many OEM options MODEL 35AA-2600-1100 SINGLE POLE AS SHOWN $96.00 LIST Specifications CONTROL MODE: On-off OUTPUT: Normally open contact rated at 35 or 60 amps, 1, 2 or 3 pole. INPUT: “J” Thermocouple with 30" leads and a 6" long Ve" diameter sheath, included as standard. LINE VOLTAGE: All ± 10% 47 to 63 Hz. 1. 24VAC 2. 115VAC 3. 230VAC OPERATING AMBIENT: Temperature 30° to 150°F/0° to 66°C Humidity 10% to 100% non-condensing. OPEN SENSOR PROTECTION: Load will shut-off in the event of an open sensor. THERMOCOUPLE COMPENSATION: Automatic. ENCLOSURE: Optional. LOAD CONNECTIONS: Heavy duty compression terminals. SET POT: 1. Integral mount assembly with F/C dial scale—Standard. 2. Remote mount assembly with F/C dial scale—Optional. MOUNTING: The unit must be mounted vertical ± 30°. ISOLATION: Sensor and control circu...