Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Honeywell, modell TE109NL

Hersteller: Honeywell
Dateigröße: 224.55 kb
Dateiname: d093f4ca-1be9-4302-8b3f-230b3c8e09f9.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


MAIN UNIT • Remove the battery compartment door. • Install 2 batteries ( UM-3 or “ AA” size 1.5V) matching the polarity as shown in the battery compartment. • Replace the battery compartment door. LOW BATTERY WARNING A low- battery indicator [ ] will appear next to the indoor or remote data reading line of the main unit warning that the corresponding batteries need replacement. 9 GETTING STARTED WEATHER DISPLAY After batteries are installed; remote sensor will transmit temperature data at 45 second intervals. The main unit may take up to two minutes to receive the initial readings. Upon successful reception, remote temperature will appear on the top line of the main unit’s display .The main unit will automatically update readings at 45-second intervals. After communication between the main unit and remote sensor has been established, secure the remote sensor in the desired location. If no signal is received from the remote sensor within two minutes, dashes [ - - - ] will be displayed. Press and hold the DOWN ( .. ) button on the main unit for two seconds to initiate another signal search. PLACEMENT OF THE UNITS The main unit can be placed on any flat surface indoors. The remote sensor can be placed indoors or outdoors, on a flat surface or mounted on the wall. REMOTE AND INDOOR TEMPERATURE The remote temperature information line is located on the top line of the main unit’s display with abbreviation OUT next to it. The wave icon is located above the OUT indicates the reception status from the remote sensor. There are three following types of the reception status may be displayed: The unit is in a searching mode. Temperature reading is securely registered. No signals detected. - - - 10 9 The indoor temperature with the icon IN is located below the remote temperature information line. NOTE: If the indoor or remote temperature goes above or below operating range stated in specifications, the main unit’s display will show dashes “ - - - ” on the corresponding line. MAXIMUM AND MINIMUM READINGS The maximum and minimum record of the indoor and remote temperature will be automatically stored in the memory of the main unit (receiver) . To display the minimum, maximum or the current reading press MEM button. If no button is pressed for the next 15 seconds, the unit will return to the current temperature display. To clear the memory, press and hold MEM (memory) button for two seconds and all previously stored readings will be erased. LOST COMMUNICATION If the main unit display line for the remote sensor reading goes blank, press and hold DOWN (Ў ) button for 2 seconds to begin a new signal search. If the signal still isn’t received, please make sure that: • The remote sensor is in its proper location. • The distance between main unit and remote sensor is not over 100 feet (30 meters) • The path between units is clear of obstacles. Shorten the distance if necessary. • Fresh batteries are installed correctly in both remote sensor and main unit. If there is no reception, please perform the following steps: • Bring the main unit and remote sensor close together. 11 • Remove four (4) small screws from the back of the remote sensor with small Phillips screwdriver, and open the battery compartment. • Remove the batteries from the battery compartment and reinstall them in the same manner. Remote sensor LED indicator will flash showing transmission of the signal. • Remove the batteries from the main unit and reinstall them in the same manner. TRANSMISSION COLLISION Signals from the other household devices such as wireless doorbells, home security systems, and entry control, may interfere with this product or cause temporary reception interruption. This is normal and will not affect the general performance of the product. The transmission and reception of the temperature readings will resume once the interference subsides. CALENDAR AND CLOCK DISPLAY MODES Date is displayed in month- date or date-month format. Each press of the MODE button will change the clock display setting between the time of day with seconds, time of day with the day of the week and a calendar. MANUAL SETTINGS CLOCK • Press and hold MODE button for 3 seconds: the year digits will flash. • Press UP ( ^ ) or DOWN ( ^ ) to change flashing digits. • After the first value is set, press MODE button again to confirm. • Continue setting month, date, time display format, 12 or 24 hour time format, hour, minute, day of the week display language, time zone and Fahrenheit or Celsius display. 12 11 • Press MODE for the last time to return to the default mode (time of day with seconds) after the last parameter is set. CLOCK ALARMS The Personal Weather Station has two time alarms – Weekday alarm ( W) and Single day alarm( S) - and one Ice Warning Alarm ( PRE- AL). • If Weekday ( W) alarm is activated, it will sound at the set time and the alarm icon will flash Mondays through Fridays • If Single (S) day alarm is activated, it will sound at the set time and the alarm icon...

Dieses Handbuch ist für folgende Modelle:
Wettermessung - TS03 (224.55 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien