Hersteller: Oregon Scientific
Dateigröße: 246.28 kb
Dateiname: 6f34974b-3527-4695-94b9-6a833193aee2.pdf
|
Anleitung Zusammenfassung
WEATHER FORECAST WINDOW SET ALTITUDE Pressure display EUP BUTTON To display the alarm time in the secondary SET ALARM Note: After replacing the batteries, Weather forecast indication shows the whole display will be 1. Press and hold the SET button for -Increases the value of a setting by To set the alarm time: resolution 1 hPa/mb window, press ALARM once. Press FEATURES (0.03inHg) MODE / SET to display the date. sunny, slightly cloudy, cloudy and turned on for about 3 seconds 2 seconds to set the altitude. The 'ALT ' one unit 1. Press ALARM to display the alarmrainy. and then show the following: indicator will turn on with the altitude Pressure sampling time. setting flashing (display in meter). cycle 15 minutes F ZONE BUTTON RF SIGNAL RECEPTION 2. Press and hold ALARM for two MODULAR BTHR WEATHER STATION B. PRESSURE READING WINDOW The accuracy of a general pressure-Power source Four pcs. UM-4 -Press to sequence through the The BHM-612A is designed to seconds. Hours digits will flash. A based weather forecast is about 70% Model : BHT663A Displays the current pressure reading. a. Weather forecast shows slightly or “AAA” size 4 U.S. time-zones: Pacific, Mountain, automatically synchronize its current time 3. Set the hours using UP . cloudy weather (a sun with the cloud to 75%. batteries Central or Eastern. and date when within range of the U.S. 4. Press ALARM. Minutes digits will indicator) Increase/decrease the altitude in steps Atomic Clock. C. PRESSURE TREND CHART WINDOW Battery life 9 month flash. or b. Pressure trend shows steady. of 10 meter by pressing When the unit is within range, its radio- B G ALARM BUTTON 5. Set the minutes using UP. button. Dimension 6.64" x 2.32" x -Changes the display and operating 6. Press ALARM to save and exit. The c. Barometric pressure shows the current control mechanism will override all manual reading. The unit takes about 24 hours 2. Press the SET button again to set 1.28" (H xWxD) settings. The benefit of a RF controlled status of the alarm clock alarm clock will be activated to store the barometric pressure date. the altitude. At this time the previous clock is sustained accuracy without the Weight 4.80 ounces automatically during the setting Until that time has elapsed, the pressure display will reappear. If the need of manual adjustment. (without battery) procedure. H RESET BUTTON pressure trend and weather forecast altitude has been changed, the ' ALT ' symbols may not reflect actual indicator flashing (about 15 minutes ) -Returns all settings to the factory set weather forecast for your area. until a new sampling takes place and default values To activate or deactivate the alarm C during normal display. the pressure reading is then compensated with the new altitude. • Press ALARM to display the alarm BATTERIES WEATHER FORECAST SYMBOLS FEATURES time. 3. Press the SET button 6 times to 1. Open the battery compartment byconfirm the setting you just entered or Your weather station detects barometric • Press ALARM to change the status removing the screw at the bottom ofwait for one minute for automatic exit. pressure changes and the LCD displays of the alarm. The respective indicator the unit. will appear. the illustsrated weather symbols which A 2. Pull out the battery holder and insert indicating the weather forecast for 12 or Note: For monitoring the local When the alarm goes off, the alarm sound two AAA-sized (UM-4) batteries in D 24 hours ahead, for an area with a radius F Complete signal reception generally takes barometric pressure reading, the user will gradually increase in volume and accordance with the polarities shown. of about 18-30 miles. E about 2 to 10 minutes, depending on the needs to select the 0 meter speed. The alarm will continue to sound Indicator displays on the unit Forecas Sunny Slightly Cloudy Cloudy Rainy 3. Slide back the battery holder into the strength of the radio signal. When the ( preset value ) for the altitude setting. for approximately two minutes unless compartment and fasten the screw. reception is completed, the signal display For monitoring the Sea Level interrupted when any button is pressed. If 4. Press RESET with a blunt stylus. will be stable. After that, the periodical barometric pressure reading at certain the alarm is not interrupted, after 2 minutes scanning will only take a few seconds. 5. When the low battery indicator [ altitude, the user needs to select the ] the alarm will silence itself and reactivate B For better reception of radio signals, place local altitude (-100 to 2500 meters i.e. appears on the display, follow the after approximately eight minutes. G the clock away from metal objects and -328 to 8223 feet) for the altitude above procedures to replace the unit Important: electrical appliances to minimize setting. The BHB-613 requires entry with new batteries. SPECIFICATIONS G interference. 1. The accuracy of weather forecasting of elevation in meters not feet. C Operating when using pressure trend alone is T...