Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Oregon Scientific, modell BAR636A

Hersteller: Oregon Scientific
Dateigröße: 822.94 kb
Dateiname: BAR636A.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


This device bundles precise time keeping, weather forecast, and indoor and outdoor temperature monitoring features into a single tool you can use from the convenience of your home. Keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know. PRODUCT OVERVIEW FRONT VIEW 1. SNOOZE / LIGHT button 2. CHANNEL: Switch remote sensor 3. : View alarm status; set alarm 4. : Press to activate or deactivate alarm 5. Weather Forecast Area 6. MODE: Change display / settings 7. and : Increase or decrease setting / activate or deactivate atomic clock 8. Outdoor and Indoor Temperature Area 9. MEMORY: View current maximum and minimum temperature readings 10. Clock / Alarm / Calendar Area 11. Moon Phase BACK VIEW 1.°C / °F switch 2.RESET hole 3.Battery compartment (cover off) LCD DISPLAY 1. Weather display 2. Outdoor temperature 3. Channel icon with sensor signal 4. Low battery icon for sensor 5. Atomic clock reception icon 6. Alarm setting 7. Alarm activated 8. Calendar 9. Indoor icon 10. Indoor temperature 11. Low battery icon for main unit 12. Time 13. Day of the week / seconds / time zone 14. Moon phase REMOTE SENSOR (THN122N) 1. LED status indicator 1.Wall mount hole 2.RESET hole 3.CHANNEL number (1-3) 4.Battery compartment (Battery compartment cover not shown) GETTING STARTED BATTERIES Main unit 3 x UM-3 (AA) 1.5V batteries Remote unit 2 x UM-4 (AAA) 1.5V batteries Insert batteries before first use, matching the polarity (+ and -) as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit. Press RESET after each battery change. NOTE Do not use rechargeable batteries. shows when batteries are low. NOTE It is recommended that you use alkaline batteries with this product for longer performance. Installing the batteries: UNIT LOCATION Main Indoor Temperature Area Remote Outdoor Temperature Area CHANGE SETTINGS To change, time, calendar and language settings: 1. Press and hold MODE for 2 seconds to enter setting mode. 2. Press or to change settings. (To reach the setting you want quickly, press and hold or .) 3. Press MODE to confirm. REMOTE SENSOR (THN122N) This product is shipped with a THN122N Thermometer Sensor that collects Temperature data. Data can be collected from up to 3 sensors. Additional sensors sold separately. SET UP SENSOR 1. Open the remote sensor battery compartment with a small Phillips screwdriver. 2. Insert the batteries, matching the polarity (+ and -) as shown in the battery compartment. SWITCH OPTION Channel Channel 1-3. If you are using more than one sensor, select a different channel for each sensor. 3. Set the channel. The switch is located in the battery compartment. 4. Place the sensor near the main unit. Press RESET on the sensor. Then, press and hold MEMORY and CHANNEL on the main unit to initiate signal sending between the sensor and the main unit. The reception icon on the main unit will blink for approximately 3 minutes while it is searching for the sensor. (Refer to the “Data Transmission” section for more information.) 5. Close the remote sensor battery compartment. 6. Secure the sensor in the desired location using the wall mount or table stand. For best results: •Insert the batteries and select the channel before you mount the sensor. • Place the sensor out of direct sunlight and moisture. • Do not place the sensor more than 98 feet (30 meters) from the main (indoor) unit. • Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls, and furniture. • Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects. • Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. You may need to experiment with various locations to get the best results. Standard Alkaline batteries contain significant amounts of water. Because of this they will freeze in low temperatures of approximately 10°F (-12°C). Disposable Lithium batteries have a much lower threshold for temperature with an estimated freezing range of below -40°F (-40°C). Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures. Extreme cold may temporarily reduce the effective range between the sensor and the base station. If the unit's performance fails due to low temperature, the unit will resume proper functioning as the temperature rises to within the normal temperature range (i.e. no permanent damage will occur to the unit due to low temperatures). DATA TRANSMISSION Data is sent from the sensor(s) every 40 seconds. The reception icon shown in the Temperature Area shows the status. ICON DESCRIPTION Main unit is searching for sensors. At least 1 Channel has been found. Channel 1 is selected (number will change depending on the sensor you select). --- shows in Ou...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien