Login:
heruntergeladen wurde: 0   Dateigröße: 4 mb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

heruntergeladen wurde: 0   Dateigröße: 2 mb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

If problem persists, contact your dealer. FUSE Branchement electrique_Page_2 5. ELECTRICAL DIAGRAM FIGURE 24 COMPOSANTES-AN.jpg pc board C:\Documents and Settings\ngagnon\Bureau\carte.bmp FIGURE 25 FIGURE 26 5.1. FUSE ACCESS All fuses are located inside the pc board box, you must remove the pc board cover to access the fuse. To do so, simply remove the 5 screws securing it in place. Make sure you put the pc board box back in place before you restart the unit. FIGURE 27 6. REPLACEMENT PARTS Conta

heruntergeladen wurde: 0   Dateigröße: 2 mb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

• Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other fl ammable materials. • Keep clothing, furniture, draperies and other fl ammable materials away. HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Figure 7.1 General Operating Parts NOTICE: If you expect that children may come into contact with this appliance, we recommend a barrier such as a decorative screen. See your dealer for suggestions. Door Handle & Spr

heruntergeladen wurde: 3   Dateigröße: 1 mb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

Round chimneys are the most efficient. The interior diameter of the chimney should be identical to the stove's smoke exhaust. A chimney which is too small may cause draft problems, since it may not have the required volume to properly evacuate the quantity of smoke resulting from the combustion. A chimney which is too large may also cause draft problems. In fact, a large chimney will be harder to warm-up and may not reach high enough temperatures to create a proper draft effect. Note that it is

heruntergeladen wurde: 2   Dateigröße: 899 kb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

2" ADJACENT WALL 2" 3" 3" 6" 6" 6" FIGURE 2 Corner installation FIGURE 3 Floor protection COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 3” inside diameter metallic pipe, either flexible or rigid, may be attached to the inlet at the stove’s rear (refer to figures 4, 5 & 6). A rodent guard (minimum .” wire mesh) must be used at the terminus (refer to figure 5). All connections must be secured and airtight by either using

heruntergeladen wurde: 0   Dateigröße: 828 kb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. Save these instructions. Some surfaces become hot at higher feeding rates. To prevent potential burns, avoid contact with those area

heruntergeladen wurde: 201   Dateigröße: 688 kb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

DIMENSIONS mm in Height : 800 31 . Width : 635 25 Depth : 485 19 1/8 O outlet flue pipe : 130 5 O burner : 255 10 Glass ( 3 ) : 460 x 280 18 x 11 Weight : 80kg 175 lbs INSTALLATION INSTRUCTIONS LOCATING THE STOVE • Install the stove as close to the chimney as possible. • Many configuration are possible, the most frequent are illustrated in figures 1,2 and 3. • Respect clearances indicated on page 1. They have been tested according to approvals. • Always respect clearances of stove pipe manufactu

heruntergeladen wurde: 11   Dateigröße: 684 kb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

9. You are now ready to connect your chimney to your stove. Simply install the inter-connecting stove pipe between the stove pipe adapter and the stove. You can follow the instructions in the following section (section 2.3) of this manual called « CHIMNEY CONNECTOR». 2.2.2 Typical installation through an existing masonry chimney You can also install your stove using your existing masonry chimney. To do so, follow the guidelines below. You may want to use a factory-built thimble, on construct you

heruntergeladen wurde: 2   Dateigröße: 684 kb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

35 3.1 SAFETY INFORMATION .............................................................................................................................. 36 3.2 FUEL ................................................................................................................................................................. 37 3.2.1 The use of manufactured logs ................................................................................................................... 38 3.2.2 Simple woo

heruntergeladen wurde: 7   Dateigröße: 684 kb   Hersteller: Drolet  
Kategorie: Standbacköfen
@name

• THIS STOVE IS NOT DESIGNED TO BE USED WITH THE DOOR OPEN. THE DOOR MAY BE OPEN ONLY DURING LIGHTING PROCEDURES. NEVER LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS OPEN. • HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. WEAR GLOVES TO OPERATE YOUR STOVE. CAUTION • THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS. • THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS. • D





Kategorien