|
Anleitung Zusammenfassung
(See Fig. 4.). •Re-tighten the pozi screw. Check the stove is level with a sprit level. •Repeat for the other rear leg. Fig. 4. Adjusting the rear feet WOOD STOVE VERSION - WOOD TRAY The wood burning tray should come fitted in your stove, if not please follow these instructions •Fully open the fire door, and remove the two round fuel retaining bars, •Locate the front of the wood tray, this is the end with no tabs protruding from each side,opposite to the rear end with the tabs protruding either side.(See Fig. 5.) •Holding the front edge of the wood tray, carefully insert the wood tray into the firebox, taking care not to damage the paint work and side / rear liner panels. •Engage the rear lugs into the slots athe the rear of the side landings. Then lower the front of the tray until this rests onto the front brace of the stove. (See Fig. 6.) Front Rear Lug Fig. 5. Wood tray identification Fig. 6. Wood Tray Installed Aarrow Ecoburn Wood & Multifuel Stoves INSTALLATION MULTIFUEL STOVE VERSIONMULTIFUEL GRATE GRATE The grates in the Aarrow Ecoburn multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "H" sitting on the high sections of the comb, and the ends marked "L" sitting on the low sections. ASSEMBLING THE GRATE To assemble the grate, fit bars to low sections of the comb first, inserting end marked "H" into rear channel with groove on underside of bar located on upstand tab, and then lowering end marked "L" onto the low section of the comb, see fig. 7. The upper bar is fitted in a similar manner, but with the end marked "L" inserted in the rear channel, and the end marked "H" seated on the high section of the comb. See fig. 8. for the assembled grate layout. GRATE BAR REPLACEMENT After extended use it may be necessary to replace some of the grate bars. Periodic inspection of the bars is recommended and the removal of any nails or wire that may be present after burning wood. All the grate bars in each appliance are identical and can easily be lifted out after removal of the fuel retainers. Remove damaged grate bars and replace with casting of the same type, fitting as per instruction above. When re-ordering replacement grate bars, see page 31of these instructions for the correct spare part code. Fig. 7. Fitting the grate bars Fig. 8. Assembled grate Aarrow Ecoburn Wood & Multifuel Stoves INSTALLATION FIREBOX LINER PANELS The Aarrow Ecoburn Wood and Multifuel stoves use firebox liner panels to the sides and back of the firebox. The throat plate sits on top of the side and rear panels. These should come fitted to your stove, if however they are not proceed as follows to fit them as follows •Open the fire door. •Remove the two round front fuel retaining bars, by lifting one end free of the bracket and sliding the remaining end out from the bracket. •Set the small liner(s) into the back of the fire. •Insert side liner panels. (See Fig. 10). •Fit the throat plate with the single bend and two cut outs to the front facing up. The projecting lugs sit on top of the side liners. The long centre tab on the back edge rests on the rear liners.The shorter turn-down tabs against the vertical face.(See Fig. 11 & 12 ). •Replace the front fuel retainer bars. Note: Neither the rear firebox liners nor the side firebox liners are "handed", both faces are suitable for direct contact with the fire. Note: Cracking of lining panels does not effect efficiency. Fig. 10. Liners inserted Fig. 11. Inserting the throat plate Fig. 9. Overall View Of Liners & ThroatPlate. Fig. 12. Liners & throat plate correctly fitted Aarrow Ecoburn Wood & Multifuel Stoves INSTALLATION OPTIONAL ADD IN BOILERS Aarrow Ecoburn Wood and Multifuel stoves offer the option of a slab boiler, which occupies the position of the rear firebox liner panels. Fitting: •Remove the fuel retainering bars, rear firebox liner panels and throat plate. •Knock out the blanking discs in the back plate corresponding to the terminals on the boiler. •Introduce the boiler to the appliance through the main fire door and locate the terminal pipes through the back plate holes and seal around boiler terminals with fire cement. •Engage locking nuts to the thread of the terminals and tighten to secure the boiler in position, ready for connection to flow and return pipes. •Replace throat plate and the fuel retainering bars. Note: On boilers the terminal which is approximately flush with the edge of the boiler and marked "TOP" must be fitted uppermost, to prevent "Kettling". WATER CONNECTIONS Heating systems The size of the heating system which can be run, will depend on the output rating of the appliance. It will be necessary to work out heat loss calculations for the system proposed in order to establish the kW/hr rating. An appliance that will meet this figure can then be chosen; (for boiler outputs please refer to the brochure)....
Dieses Handbuch ist für folgende Modelle:Standbacköfen - EcoBurn AFS1221 (2.1 mb)
Standbacköfen - EcoBurn BK043 (2.1 mb)
Standbacköfen - EcoBurn BK043 (2.1 mb)